Profibus T1H-PBC Скачать руководство пользователя страница 6

Expansion I/O Configurations

T1K-10CBL        

 

T1K-10CBL-1*    

 

Right side to left side 

expansion cable

Using T1K-10CBL expansion cable  

and T1K-05CBL-RR expansion cable

Expansion cables

T1K-05CBL-LL     

 

T1K-05CBL-LL-1* 

 

Left side to left side 

expansion cable

Using two T1K-10CBL expansion cables

Using T1K-05CBL-RR expansion cable  

and T1K-05CBL-LL expansion cable

Using T1K-05CBL-RR expansion cable 

The T1K-10CBL(-1) connects the right 
side of an I/O base to the left side of 
the next I/O base. A maximum of two  
T1K-10CBL(-1) cables can be used per 
expansion system.

The T1K-05CBL-LL(-1) connects the left 
side of an I/O base to the left side of the 
next I/O base. Only one T1K-05CBL-LL 
(-1) cable can be used per expan-
sion system and must be used with a 
T1K-05CBL-RR cable

This cable cannot 

be connected to the left side of the network 

interface base.

Some of the examples below show 
the T1K-05CBL-RR expansion 
cable. This cable is no longer 
available. 

Refer to the examples if you already 
have these cables. If you are 
purchasing new cables, we recom-
mend the T1K-10CBL(-1) cables.
The T1K-05CBL-RR connects the 
right side of an I/O base to the right 
side of the next I/O base. A maximum 
of one T1K-05CBL-RR cable can be 
used per expansion system. 

Note: 

When this cable is used, the expan-

sion I/O assignments are from right 

to left (reversed).

*Note: 

The (-1) versions of the expansion cables pass 24VDC through on an isolated wire. (All cables pass the 5VDC base 

power.) Any local expansion DC input module configured for “internal power” (current sourcing) must either have a power supply 
preceding it on the same base or, have a (-1) version cable pass 24VDC from a power supply on the preceeding base.

T1K-10CBL

T1K-05CBL-RR 
(Retired Product)

T1K-05CBL-RR 
(Retired Product)

T1K-05CBL-RR 
(Retired Product)

T1K-05CBL-LL

In the system below, power supplies can be used anywhere.

Power supplies can be used anywhere in the first two bases, 
but not in the last expansion base.

A power supply can be 
used on either base.

Power supplies can be used anywhere in the first and third 
bases, but not in the second base.

T1K-10CBL(-1)

Power supplies can be used anywhere in the first base, but not 
in the second base.

I/O Addressing

I/O Addressing

I/O Addressing

I/O Addressing

T1K-10CBL(-1)

Do not connect a 

 

T 1 K - 0 5 C B L - L L ( - 1 ) 
to the left side of the 
network interface base.

Cable length = 1.0m

Cable length = 0.5m

T1K-05CBL-RR        RETIRED 
Right side to right side  

expansion cable is no longer 

available

w w w . l a m o n d e . c o m       - f i e l d I O

Universal Field I/O

tFED-56

.

Содержание T1H-PBC

Страница 1: ...Terminator I O modules and for controlling them with a PROFIBUS master Using our PROFIBUS I O sub system will increase installation flexibility as well as save on wiring costs The T1H PBC module supports all Terminator discrete and analog I O modules The T1H PBC also offers the following features Cost effective With a single network for devices hardwiring costs are reduced Easy connectivity Low co...

Страница 2: ...n vertical connector 9 pin male D sub Terminator I O T1H PBC or any PROFIBUS ISA PCI Personal Computer Master Slave Card Terminator I O Modules Supported Discrete Types Analog Types 8 point DC Input 8 channel Current Input 8 point AC Input 8 channel Voltage Input 16 point DC Input 8 channel Current Output 16 point AC Input 8 channel Voltage Output 8 point DC Output 16 channel Current Input 8 point...

Страница 3: ...ple it is recommended to leave 2 depth for ease of access and cable clearance However your distance may be greater or less Also check the instal lation guidelines for the recommended cabinet clearances 48mm 1 89in 80mm 3 15in 80mm 3 15in 48mm 1 89in 80mm 3 15in 48mm 1 89in 89mm 3 5in 80mm 3 15in 83 3mm 3 28in Power Supply Network Interface Module Half size I O Module with Base System Depth Full si...

Страница 4: ...lation Terminator I O modules feature separate terminal bases for easy installation To install I O modules 1 Slide the module into its terminal base until it clicks into position 2 Hook upper DIN rail tabs over the top of DIN rail and press the assembly firmly onto the DIN rail 3 Slide the module along the DIN rail until it engages with the adjacent module DN ASB 1 angled mounting bracket Optional...

Страница 5: ...al Block Phoenix Contact MVSTBW 2 5 4 ST 5 08 BK MVSTBW 2 5 6 ST 5 08 BK Note 500mA 24VDC can be achieved by lowering the 5VDC from 2000mA to 1500mA Power Budget Example Module 5VDC 24VDC T1K 01AC 2000mA 300mA T1H EBC100 300mA 0mA T1K 16ND3 70mA 0mA T1K 16TD2 200mA 0mA T1F 08AD 1 75mA 50mA Remaining 1355mA 250mA Module 5VDC 24VDC Analog Input Modules T1F 08AD 1 75 50 T1F 08AD 2 75 50 T1F 16AD 1 75...

Страница 6: ... base A maximum of one T1K 05CBL RR cable can be used per expansion system Note When this cable is used the expan sion I O assignments are from right to left reversed Note The 1 versions of the expansion cables pass 24VDC through on an isolated wire All cables pass the 5VDC base power Any local expansion DC input module configured for internal power current sourcing must either have a power supply...

Страница 7: ... it easy to wire 2 and 3 wire devices ensuring clean wiring with only one wire per termination External user supplied 24VDC power or auxiliary 24VDC terminals from T1K 01AC can be easily applied directly to one end of the terminal rows and jumpered across each base in the system This is a convenient solution for powering analog I O and discrete DC output devices whose modules do not have direct ac...

Отзывы: