5.4.6 Total measuring range (units)
The total measuring range is defined by the parameter "Total measuring range in
measuring units." The device has two different operating modes, depending on the
specified measuring range. When the device receives a parameter message, it checks
the scaling parameters if a binary scaling can be used. If binary scaling can be used,
the device selects operating mode A (see following explanation). If not, operating
mode B is selected.
A. Cyclic operation (binary scaling)
Cyclic operation is used when operating with 2
X
number of turns (2, 4, 8, 16, 32, 64,
128, 256, 512, 1024, 2048 and 4096 number of turns). If the desired measuring range is
equal to the specified singleturn resolution * 2
X
(where x<= 12) the encoder operates
in endless cyclic operation (0 – max – 0 –max…). For example: If the position value
increases above the maximum value by rotating the encoder shaft, the encoder
continues from 0.
Example of a cyclic scaling:
Measuring units per revolution
= 1000
Total measuring range
= 32 000 (2
5
= number of revolutions 32)
Pictur 14 Cyclic Scaling