3. RANGES OF APPLICATION

These pumps are made for pumping clear water (free of mud and sand, see technical data and 

point 6)

The pumps are made for the following ranges of application:

l

 Filling and emptying rain tanks and containers

l

 For water re-circulation

l

 For rainwater use in house and garden

l

 Pumping water from a brook a stream

l

 Use in a pond

l

 Others

English 3

IMPORTANT!

The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any gua-

rantee is void in case of improper use. They are not suitable for pumping flammable liquids or for use 

in places where there is danger of an explosion. The pumps are designed for home use in the house 

and garden. The pumps are not designed for continuous operation or for professional work. Never run 

more than 5 minutes against a closed valve pump. Save the pump against dry running (install dry run 

protection). 

Never start and stop the pump more than 20 times per hour. When the pump clocks, any 

claim under warranty is void. Not suitable for use with solar photovoltaic panels. Submersi-

ble pumps may not be used in swimming pools.

4. OPERATION

 

The installation must be performed by a qualified professional.

 

 Please, check each time before using, the electrical connections and the cables are not 

damaged. Check before the installation whether the electrical connections are earthed 

according to the statutory regulations and are installed. The pump is to be secured 

through a RCD circuit breaker with release current of 30 mA. 

Also, it is NOT recommended to perform, for example, a cable extension. It is not certain 

whether this modification is technically correct, so this warranty is void. It must be en-

sured that the pump is sufficiently cooled during prolonged operation.

 

 It is not recommended to perform even cable extensions or other technical modifica-

tions. A transfer of mechanical loads or vibrations from the pump or must be eliminated 

through appropriate measures (rubber buffers, braided hoses, line fixation, etc.).

 

 All cables to and from the pump must be sealed. Check valve and water pipes for leaks 

at least by means of pressure testing for 24h.

5. INSTALLATION (Please also refer to page 12)

Attach a sufficiently long and strong rope to the handle before first use. The pump is submerged 

into the liquid on this holding rope and can also be carried with it as well as with the handle.

Note:
 

 In the case of continuous use of the pump with the rope, the condition of the rope 

must be checked regularly as it can decay and break over time.

l

  Connect pressure pipe. 

For occasional use, use a suitable water hose. The use of rigid pipes with a non-return valve 

is recommended for use at a fixed location. This prevents return flow of the liquid when swit-

ching off.

l

  Screw pressure line onto the pressure connection. All threaded connections must be sealed 

with thread sealing tape (e. g. Teflon® tape).

l

  When using a hose, screw a suitable hose adapter onto the pressure connection. – Push the 

hose firmly onto the hose adapter and secure with a hose clamp.

Содержание REGEN-STAR SUPER 750

Страница 1: ...ts and mistakes reserved Newest information about our products can be found online Technische Änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de TAUCHPUMPE REGEN STAR 800 3 TAUCHPUMPE REGEN STAR SUPER 750 TAUCHPUMPE REGEN STAR SUPER 900 ...

Страница 2: ...port damages are immediately to be reported to the package distributor and to us in writ ten form 2 English 1 INTRODUCTION We would like to congratulate you on the purchase of our pump We appreciate your trust That s why funtional security and operational safety stands by us on first place To prevent damage to persons or property you should read this user manual carefully Please observe all safety...

Страница 3: ...ed The pump is to be secured through a RCD circuit breaker with release current of 30 mA Also it is NOT recommended to perform for example a cable extension It is not certain whether this modification is technically correct so this warranty is void It must be en sured that the pump is sufficiently cooled during prolonged operation It is not recommended to perform even cable extensions or other tec...

Страница 4: ...o lack skills experience and knowledge only if they are supervised These aforementioned persons should only use the appliance while adhering to safe instructions and resulting dangers l Cleaning and maintenance must not be carried out by children without supervision l The pump must not be used or operated under any circumstances when there are people in the same water l Under certain cirumstances ...

Страница 5: ...ou how to proceed with case related Returns please sufficient postage Unfortunately not prepaid returns can not be accepted because they are filtered out before delivery Our service we provide in Germany The warranty does not cover l Improper installation self installation unauthorized persons l Material wear sealing rings impeller wheels impeller chambers l Unjustified interventions or changes in...

Страница 6: ...below the rele vant EU directives and harmonized corresponds to the EU standard for security This declaration is valid insofar as no changes to the product are made Authorized person to keep the technical documents 1A Profi Handels GmbH Unterriethstraße 37 D 65187 Wiesbaden Low Voltage Directive 2006 95 EC EC Electromagnetic compatibility directive 2004 108 EC The following harmonized standards EN...

Страница 7: ...verzüglich dem Speditionsunternehmen und uns schriftlich mitzuteilen 1 VORWORT Zum Kauf unserer Pumpe möchten wir Sie recht herzlich beglückwünschen Wir wissen Ihr Vertrauen zu schätzen Aus diesem Grund stehen bei uns Funktions und Betriebssicherheit an erster Stelle Um Personen und Sachschäden zu vermeiden lesen Sie die vorliegende Bedie nungsanleitung bitte aufmerksam durch Bitte beachten Sie al...

Страница 8: ...wässerung l Sonstige Klarwasserförderung 4 INBETRIEBNAHME Die Installation ist von einer qualifizierten Fachkraft auszuführen Bitte überprüfen Sie vor jeder Inbetriebnahme die elektrischen Anschlüsse sowie das Kabel auf Unversehrtheit Bitte prüfen Sie vor der Installation ob der elektrische Anschluss entsprechend der gesetz lichen Vorschriften geerdet und installiert ist Achten Sie darauf daß die ...

Страница 9: ...ebrauchs des Gerätes unterwiesen worden sind und die daraus resultierenden Gefahren verstehen l Die Reinigung und Wartung darf nicht von Kindern ohne Beaufsichtigung durchgeführt werden l Die Pumpe darf unter keinen Umständen benutzt oder in Betrieb genommen werden wenn sich Personen im Wasser aufhalten l Unter Umständen ist es möglich daß eine Verschmutzung des Wassers durch Ausflie ßen von Schmi...

Страница 10: ...a 2000 Stunden sollten die me chanischen Bauteile wie Laufräder Laufkammern Dichtungen etc auf Unversehrtheit hin überprüft und ggf getauscht werden Nach 3000 Betriebsstunden sollte ggf das Öl in der Kammer ausgetauscht werden nur bei ölgetauchten Motortypen Bitte nur bis zu 80 auffüllen und die Dichtungen stets auf Dichtigkeit überprüfen Bei abrasiven Materialien wie Sand verkürzt sich die Wartun...

Страница 11: ...ern an dem Produkt keine Veränderungen vorgenommen werden Autorisierte Person zur Aufbewahrung der technischen Dokumente 1A Profi Handels GmbH Unterriethstraße 37 D 65187 Wiesbaden Richtlinie Niederspannung 2006 95 EG Richtlinie Elektromagnetische Verträglichkeit 2004 108 EG Folgende harmonisierte Normen EN 60335 1 2012 A11 2014 EN60335 2 41 2003 A2 2010 EN62233 2008 EN55014 1 2006 A2 2011 EN55014...

Страница 12: ...Spannung 230V 50 Hz 230V 50 Hz 230V 50 Hz Measures in cm Maße in cm tba folgt tba folgt tba folgt Weight Gewicht ca 9 kg ca 16 kg ca 16 kg Pressure connection Druckanschluss G11 4 G1 G1 Cable length Kabellänge 10 m 25 m 25 m All products listet in this manual are Made in PRC Alle Produkte in dieser Bedienungsanleitung sind Made in VRC 14 INSTALLATION SCHEME INSTALLATIONS SCHEMA Panzerschlauch Flex...

Отзывы: