background image

Contents

  1.  Introduction ...........................................................................................................................................................

 2

  2.  In general  .............................................................................................................................................................

 2

  3.  Installation  ............................................................................................................................................................

 2

  4.  Operation ..............................................................................................................................................................

 3

  5.  Security tips ...........................................................................................................................................................

 3

  6.  Servicing ...............................................................................................................................................................

 3

  7.  Guarantee regulations  ..........................................................................................................................................

 3

  8.  Recognising and repairing of mistakes  ................................................................................................................

 4

  9.  Notes on Product Liability  ...................................................................................................................................

 4

10.  Notes on Disposal  ...............................................................................................................................................

 4

11.  EU Declaration of Conformity  ..............................................................................................................................

 4

12.  Technical Data  .....................................................................................................................................................

 8

13.  Electrical Installation  ...........................................................................................................................................

 8

2 English

1. INTRODUCTION

We would like to congratulate you  on the purchase of our flow switch. We appreciate your trust. That‘s why funtional 

security and operational safety stands by us on first place.

 

 To prevent damage to persons or property, you should read this user manual carefully. Please 

observe all safety precautions and instructions for proper use of the AC3. Failure to follow the 

instructions and safety precautions can result in injury or property damage.

   Please keep this manual with the instructions and safety instructions carefully in order to at any 

time you can restore them.

2. IN GENERAL

The AC3 is a circuit device that an electrical load (pump) automatically switches on and off. The device monitors the 

pressure and the flow in the pressure line. Depending upon the pressure or the flow rate, the AC switch 5 one or 

more electrical consumers (MAX 12A) on and off.

The AC3 is to be used exclusively for non abrasive clear water without debris and other dirt. In the opposite case, an 

effective pre-filter with a mesh size should be installed no coarser than 0.2 mm in front of the device.

The manometer indicates the pressure in the system. It helps to monitor the proper pump function and to detect 

leaks in the system.

Make sure after unpacking that the data given on the nameplate agree with the foreseen operating conditions. When 

in doubt, the operation is prohibited.

Transport damages are reported immediately to the transport company and to us in writing.

Please read the user manual before using

the flow switch

Warning sign

Pull power plug

Warning of electrical voltage 

SAFETY INSTRUCTION AND WARNINGS

3. INSTALLATION

 

l

  The device is installed at any point between the outlet of the pump and the first collector, so that the direction of the 

arrow on the side between the two 1 „connections with the flow direction of the fluid in the pipeline matches. Make sure 

that the hydraulic connections are completely sealed. If a pump with maximum pressure used above 7 bar, a pressure 

reducer at the entrance of the device must be installed. The pump controller is to be used only for pumps that produce a 

minimum pressure of 2.5 bar at the device installation point.

l

  The electrical connection of the unwired version is after the electrical diagram (see paragraph. 13) produce. If a consu-

mer is used with a power more than 1.1 kW and the ambient temperature is higher than 25 ° C, must be used for the 

wiring is not less than 99 ° C cable with heat resistance. For wiring, only use this specific pliers. When ready to plug in 

wired version, it is sufficient to connect the power cord of the pump with the outlet of AC3 and shut the power plug of AC3 

to an electrical outlet the power grid on.

 

l

  The pressure at which the device starts is set to 1.5 bar, this pressure is optimal for most applications. It can be changed 

by an expert by means of adjusting screw (top).

l

 The height of the water column above the AC3 should not exceed 10m.

Warning: no additional check valve should be installed between the pump and the AC3, as it sometimes 

causes problems.

Содержание FLOW SWITCH AC3

Страница 1: ...kfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de 1 AC3 AUTOMATIC CONTROLLER VERKABELT 1A AZ AC3 V 2 AC3 AUTOMATIC CONTROLLER UNVERKABELT 1A AZ AC3 U FLOW SWITCH AC3 DURCHFLUSSWÄCHTER AC3 Version 21 06 2 0 OPERATING INSTRUCTIONS Translation BEDIENUNGSANLEITUNG Original ...

Страница 2: ...ata given on the nameplate agree with the foreseen operating conditions When in doubt the operation is prohibited Transport damages are reported immediately to the transport company and to us in writing Please read the user manual before using the flow switch Warning sign Pull power plug Warning of electrical voltage SAFETY INSTRUCTION AND WARNINGS 3 INSTALLATION l The device is installed at any p...

Страница 3: ...ree to flush any case as previously described Opening the device on non return valve is prohibited and always results in the loss of any existing warranty In addition persons could be dangerous when Operating a clocking pump occur so that the pump may be operated under any circum stances continue Until the device replacement the pump must be taken out of service For abrasive materials such as sand...

Страница 4: ...below the relevant EU directives and harmonized with EU standards for safety This declaration is valid insofar on the product no changes are made Authorized person to keep the technical documents 1A Profi Handels GmbH Unterriethstraße 37 D 65187 Wiesbaden Low Voltage Directive 2006 95 EC EC Electromagnetic compatibility directive 2004 108 EC The following harmonized standards EN 60730 1 2000 A1 A2...

Страница 5: ... Einbaustelle erzeugen l Der Elektroanschluss der unverkabelten Ausführung ist nach dem elektrischen Plan siehe Pkt 13 herzustellen Falls ein Verbraucher mit einer Leistung über 1 1 kW verwendet wird und die Raumtemperatur höher als 25 C ist müssen für die Verdrahtung Kabel mit Wärmebeständigkeit nicht unter 99 C verwendet werden Für die Verdrahtung ausschließlich die dazu bestimmte Zange benutzen...

Страница 6: ...eben frei zu spülen Das Öffnen des Gerätes am Rückschlagventil ist unzulässig und führt stets zum Verlust der ggf bestehenden Garantieansprüche Darüber hinaus können erhebliche Gefahren beim Betrieb einer taktenden Pumpe entstehen so dass die Pumpe unter keinen Umständen weiter betrieben werden darf Bis zum Geräteaustausch ist die Pumpe außer Betrieb zu setzen Bei abrasiven Materialien wie Sand ve...

Страница 7: ...sierte Servicewerkstätte vorgenommen werden haften wir nur insofern wenn Original Ersatz teile und Zubehör verwendet wurden 10 ENTSORGUNGSHINWEISE Elektro Geräte mit dem Symbol der durchgestrichenen Mülltonne dürfen nicht über den Hausmüll entsorgt werden sondern sind an einer Annahmestelle für Recycling von elektronischen Geräten abzugeben Bei der deutschen Registrierungsstelle EAR sind wir unter...

Страница 8: ...LEKTRISCHER ANSCHLUSS PLAN UND INSTALLATIONSSCHEMA 1 Pump Pumpe brown braun Phase 2 Pump Pumpe green yellow grün gelb Erde 3 Pump Pumpe blue blau Null 4 Power Netz brown braun Phase 5 Power Netz green yellow grün gelb Erde 6 Power Netz blue blau Null The device is normally connected as shown in figure Pumps can be opera ted on the device with higher performance with a current consumption over 10A ...

Отзывы: