background image

4 English

English 5

l

  Screw pressure line onto the pressure connection. All threaded connections must be sealed 

with thread sealing tape (e. g. Teflon® tape).

l

  When using a hose, screw a suitable hose adapter onto the pressure connection. – Push the 

hose firmly onto the hose adapter and secure with a hose clamp.

l

  The pump can be lowered up to a water depth of 7m.

l

  Install the appliance so that the suction openings cannot be blocked by foreign bodies (place 

the appliance on a firm, even base if necessary).

l

 Ensure that the appliance is stable.

Integrated pump switch with dry-running protection.

The electronic pump switch regulates the switching on and off of the pump automatically. If a 

consumer is turned on, the pump switches on and switches off again when it closes. 
If there is a lack of water (low or no water flow), the pump switching device switches the pump 

off and protects it from running dry. 

7. SERVICING

 

 Under normal pumping conditions the pump requires no servicing. From an operating pe-

riod (with clear water) of approx. 2000 hours the mechanical components should be che-

cked: impeller wheels, chambers, sealing rings etc. on wear and if necessary be changed. 

 

With abrasive materials like sand the servicing duration can become shorter.

 

The following controls should be carried out regularly:

 

l

 Intactness of the electric cable

 

l

 That the connection hoses are not bent or broken

 

l

 Cleanness of the pump medium 

 

 Moreover, the pump should be emptied with risk of frost, be washed out with clear water 

and stored dry.

8. GUARANTEE REGULATIONS

For all manufacturing and material defects, the statutory warranty applies. In these cases we 

take the replacement or repair of the pump. Shipping costs shall be borne by our company, 

except as required by law. Please report the warranty on our service platform http://www.profi-

pumpe.de/service.php. We will inform you how to proceed with case-related. Returns please 

sufficient postage. Unfortunately not prepaid returns can not be accepted because they are 

filtered out before delivery. Our service we provide in Germany.

The warranty does not cover:

l

 Improper installation (self-installation, unauthorized persons)

l

 Material wear (sealing rings, impeller wheels, impeller chambers)

l

 Unjustified interventions or changes in the pump

l

 Damages by selffault

l

 Improper servicing and improper use

l

 DRY RUNNIG (Also partially!) of the pump

moreover, we give no damage compensation for secondary damages!

Maximum pumping head 

10

m

Ø 200mm (minimum)

Ø 300mm (recommended)

80

0

mm (minimum)

Distance to ground

 min. 300mm

towing rope

power supply

Distance to ground

min. 300mm

towing 

rope

Maximum pumping head 

10

m

Ø 200mm (minimum)

Ø 300mm (recommended)

power supply

80

0

mm (minimum)

6. SECURITy TIPS

 

l

 Obey absolutely valid regulations on the electrical security 

 

l

 Never run pump dry

 

l

 Pumping inflammable, as well as all other aggressive liquids is prohibited

 

l

 Pay attention to the medium temperature max. 35°C

 

l

 Never pull the pump on the electrical cable or pressure hose

 

l

 Avoid cross section narrowing

 

l

 Pay attention to the given particle size 

 

l

  The grain size mentioned does not refer to sand or stones but rather to soft, flexible 

particles such as fluff and similar which the rotor cannot wedge inside the pump.

 

l

  During longer unused times, clean the pump, wash it out with clear water, dry and store it 

at room temperature

 

l

 Test wells for enough flowing water (dry run danger)

 

l

  The pump is to be secured through a RCD circuit  breaker with a release current of 30 mA.

 

l

  The electrical connections are always to be carried out by an authorised professional.

 

l

  The pump may be used by children aged 8 years and above as well as persons with 

reduced physical, sensory or mental abilities or those who lack skills, experience and 

knowledge only if they are supervised. These aforementioned persons should only use 

the appliance while adhering to safe instructions and resulting dangers.

 

l

  Cleaning and maintenance must not be carried out by children without supervision.

 

l

  The pump must not be used or operated under any circumstances when there are  

people in the same water.

 

l

  Under certain cirumstances, it is possible that that contamination of water is caused  

by leakage.

ThE mANUfACTURER ExPLAINS:

l

  To take over no responsibility in the case of accidents or damages on the basis of careless-

ness or disregard to the instructions in this book.

l

  To reject every responsibility for the damages which originate from the improper use of the pump.

Содержание ENVIRO-TECH 550

Страница 1: ...ITUNG de Technical changes misprints and mistakes reserved Newest information about our products can be found online Technische Änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de Tauchdruckpumpe ENVIRO TECH 550 TP EU02144 ...

Страница 2: ...uit breaker with release current of 30 mA is technically correct so this warranty is void It must be ensured that the pump is sufficiently cooled during prolonged operation It is not recommended to perform even cable extensions or other technical modifications The lines to the pump must be installed always steadily rising A transfer of mechanical loads or vibra tions from the pump or must be elimi...

Страница 3: ...unauthorized persons l Material wear sealing rings impeller wheels impeller chambers l Unjustified interventions or changes in the pump l Damages by selffault l Improper servicing and improper use l DRY RUNNIG Also partially of the pump Moreover we give no damage compensation for secondary damages Maximum pumping head 10m Ø 200mm minimum Ø 300mm recommended 800 mm minimum Distance to ground min 30...

Страница 4: ... the crossed trash bin are not permitted to be disposed in your household garbage We are registered at the German registration department EAR under the WEEE No DE25523173 This symbol means that you re not allowed to treat this product as a regular household waste item it has to be disposed at a recycling collection point of electri cal devices This is the best way to save and protect our earth THA...

Страница 5: ...me aus Bächen und Flüssen l Teichentwässerung l Sonstige Klarwasserförderung WICHTIG Diese Pumpe ist für das Pumpen von sauberem Wasser und chemisch nicht aggressiven Flüs sigkeiten bestimmt Bei nicht besitmmungsgemäßem Einsatz entfällt jegliche Gewährleistung Sie sind nicht für das Pumpen von brennbaren Flüssigkeiten oder für den Betrieb an Orten an denen die Gefahr einer Explosion besteht geeign...

Страница 6: ...engung vermeiden l Achten Sie auf die angegebene Partikelgröße l Die Partikelgröße bezieht sich nicht auf Sand oder Steine sondern um weiche flexible Partikel wie Fusseln und ähnliches die nicht den Rotor der Pumpe blockieren können l Bei längeren Stillstandszeiten die Pumpe säubern mit klarem Wasser spülen und tro cken bei Zimmertemperatur lagern l Brunnen auf ausreichend nachfliesendes Wasser te...

Страница 7: ...Laufrad ist abgenutzt Laufrad wechseln Filter ist verschmutzt Filter reinigen Beim Einschalten der Pumpe wird der FI Schalter aus gelöst Pumpe ist undicht geworden Pumpe auf Feuchtigkeitsschäden untersuchen Kondensatbildung im elektrischen Anschluss Klemmkasten Vom Stromnetz trennen Lieferanten informieren 12 EU Konformitätserklärung Die umseitig benannten Produkte entsprechen der in den Verkehr g...

Страница 8: ...ECH 550 TP EU02144 Power P1 Leistung P1 550 W Max pump capacity Max Fördemenge 7 2 m h Max pressure Max Druck 4 2 bar Max pump height Max Förderhöhe 42 m Max water temperature Max Wassertemperatur 40 C Max submersion depth Max Eintauchtiefe 7 m Protective class Schutzklasse IP68 Tension Spannung 230V 50 Hz Measures in cm Maße in cm 17 8x42 8 Weight Gewicht ca 9 4 kg Connection out Anschluss Drucks...

Отзывы: