background image

6. INSTALLATION SCHEME

7. SECURITY TIPS

 

l

 Obey absolutely valid regulations on the electrical security 

 

l

 Never run pump dry

 

l

 Pumping inflammable, as well as all other aggressive liquids is prohibited

 

l

 Pay attention to the medium temperature max. 35°C

 

l

 Never pull the pump on the electrical cable or pressure hose

 

l

 Avoid cross section narrowing

 

l

 Pay attention to the given particle size 

 

l

  During longer unused times, clean the pump, wash it out with clear water, dry and store it 

at room temperature

 

l

 Test wells for enough flowing water (dry run danger)

 

l

  The pump is to be secured through a RCD circuit  breaker with a release current of 30 mA.

 

l

  The electrical connections are always to be carried out by an authorized professional.

 

l

  The pump may be used by children aged 8 years and above as well as persons with 

reduced physical, sensory or mental abilities or those who lack skills, experience and 

knowledge only if they are supervised. These aforementioned persons should only use 

the appliance while adhering to safe instructions and resulting dangers.

 

l

  Cleaning and maintenance must not be carried out by children without supervision.

 

l

  The pump must not be used or operated under any circumstances when there are 

 

people in the same water.

 

l

  Under certain circumstances, it is possible that contamination of water is caused 

 

by leakage.

4 English

Schematic illustration as an example. Please refer to the offer  

description for the contents of delivery.

Schematic illustration as an example. Please refer to the offer  

description for the contents of delivery.

*) If necessary, further/differ-

ent country-specific regula

-

tions must be observed.

*) If necessary, further/

different country-specific reg

-

ulations must be observed.

Содержание BP011105

Страница 1: ...changes misprints and mistakes reserved Newest information about our products can be found online Technische Änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf https www profi pumpe de 2 BRUNNEN STAR 370 5 BP011105 2 5 BRUNNEN STAR 550 5 BP01123 2 5 BRUNNEN STAR 250 5 BP01121 ...

Страница 2: ...t damages are immediately to be reported to the package distributor and to us in writ ten form 2 English 1 INTRODUCTION We would like to congratulate you on the purchase of our pump We appreciate your trust That s why functional security and operational safety stands by us on first place To prevent damage to persons or property you should read this user manual carefully Please observe all safety p...

Страница 3: ...p ade quately secured against dry running The pump must not be used in swimming pools Not suitable for use with solar photo voltaic panels 4 OPERATION The installation must be performed by a qualified professional Please check each time before using the electrical connections and the cables are not damaged Check before the installation whether the electrical connections are earthed according to th...

Страница 4: ...y children aged 8 years and above as well as persons with reduced physical sensory or mental abilities or those who lack skills experience and knowledge only if they are supervised These aforementioned persons should only use the appliance while adhering to safe instructions and resulting dangers l Cleaning and maintenance must not be carried out by children without supervision l The pump must not...

Страница 5: ...lows down or stops Pump is inserted to deep Insert pump not so deep Hose connections systems have a leak Check hose connection systems Impeller wheel is worn down Change impeller wheel Filter has become dirty Clean filter THE MANUFACTURER EXPLAINS l To take over no responsibility in the case of accidents or damages on the basis of careless ness or disregard to the instructions in this book l To re...

Страница 6: ...GmbH Unterriethstr 37 65187 Wiesbaden confirms that the products placed on the market execution referred to the relevant regulations below the rele vant EU directives and harmonized corresponds to the EU standard for security This declaration is valid insofar as no changes to the product are made Authorized person to keep the technical documents 1A Profi Handels GmbH Unterriethstraße 37 D 65187 Wi...

Страница 7: ... Stelle Um Personen und Sachschäden zu vermeiden lesen Sie die vorliegende Bedie nungsanleitung bitte aufmerksam durch Bitte beachten Sie alle Sicherheitshinweise und Anweisungen zum sachgemäßen Gebrauch der Pumpe Eine Nichtbeachtung der Anweisungen und Sicherheitshinweise können zu körperlichen Schäden oder zu Sachschäden führen Bitte bewahren Sie die Bedienungsanleitung mit den Anweisungen und S...

Страница 8: ...als 2 3 Minuten gegen ein geschlossenes Ventil laufen lassen Pumpe gegen Trockenlauf entsprechend sichern Trockenlaufschutz installieren Die Pumpe darf nicht in Schwimmbädern verwendet werden Nicht für Betrieb an Solar Fotovoltaikanlagen geeignet 4 INBETRIEBNAHME Die Installation ist von einer qualifizierten Fachkraft auszuführen Bitte überprüfen Sie vor jeder Inbetriebnahme die elektrischen Ansch...

Страница 9: ...ren sowie von Personen mit verringerten physischen sensorischen oder mentalen Fähigkeiten oder aufgrund mangelnder Erfahrung und Wissen nur unter Beaufsichtigung benutzt werden oder wenn diese bezüglich des sicheren Gebrauchs des Gerätes unterwiesen worden sind und die daraus resultierenden Gefahren verstehen l Die Reinigung und Wartung darf nicht von Kindern ohne Beaufsichtigung durchgeführt werd...

Страница 10: ...Stromkabels l Saubere Führung der Leitungen z B keinen Knick l Sauberkeit des Mediums keinen Sand keinen Schlamm Außerdem sollte bei Frostgefahr die Pumpe entleert mit klarem Wasser durch spült und trocken eingelagert werden 9 GARANTIEBESTIMMUNGEN Für alle Fabrikations und Materialfehler gilt die gesetzliche Gewährleistung In diesen Fällen übernehmen wir den Umtausch oder die Reparatur der Pumpe V...

Страница 11: ...nsofern an dem Produkt keine Veränderungen vorgenommen werden Autorisierte Person zur Aufbewahrung der technischen Dokumente 1A Profi Handels GmbH Unterriethstraße 37 D 65187 Wiesbaden Wiesbaden den 01 10 2020 ppa Peter Neumüller Deutsch 11 Problem Mögliche Ursache Lösung Beim Einschalten der Pumpe wird der FI Schalter ausgelöst Pumpe ist undicht geworden Pumpe auf Feuchtigkeitsschäden untersuchen...

Страница 12: ...re Max Druck 5 1 bar 4 6 bar 8 4 bar Max pump height Max Förderhöhe 51 m 46 m 84 m Max water temperature Max Wassertemperatur 35 C 35 C 35 C Max particle size Max Partikelgröße 0 2 mm 0 2 mm 0 2 mm Max sand content Max Sandgehalt 0 2 0 2 0 2 Protection grade Schutzklasse IP58 IP58 IP58 Electrical tension Spannung 230V 50 Hz 230V 50 Hz 230V 50 Hz Connection pressure side IT Anschluss Druckseite IG ...

Отзывы: