6. OPERATION AND FUNCTION

6.1 Operation from battery box

l

  

Continual use mode:

 Press button (power), indicator light (on) lit, pump will 

work continously until battery runs out of all power.

l

  

Timer function mode:

 Press button (timer) lit, indicator light (2 hours) lit, 

pump will be on for 2 hours, off for 22 hours and will repeat this timing set 

every day at the same time. To select 3 hours or 4 hours, timer by pressing te 

button (timer) repeatedly until indicator light (3 hours) or (4 hours) lit. The pump 

will be on for 3 hours, off for 21 hours at 3 hours timer set, on for 4 hours, off 

for 20 hours at 4 hours timer set.

l

  

Winter mode:

 Press button (winter), indicator light (pulse) lit, pump will be on for 20 seconds in every 60 seconds. 

We recommend to use this mode to extend battery life time in winter or in poor weather.

l

  

Pump flow control:

 Press button (flow rate) repeatedly to adjust the pump flow rate (3 levels for selection).

l

 

 Low  Battery:

 If you find the indicator light (low Bat.) blinking, that means battery power is low. The system will shut 

off the pump/LED light shortly to protect the battery. Now the (low Bat.) light will keep blinking, when battery power 

is low and the pump and LED light will not work until battery is recharged.

NOTE: Higher flow rate will cost more power and will reduce the battery life time.

4. FROST

Frost can cause damage to the pump. In freezing the pump, pipes and water tank must be emp

-

tied, rinsed with clean water and stored dry.

5. ASSEMBLY INSTRUCTION

5.1  Join the bracket, tubes and ground spike together 

and then attach the solar panel to the bracket. Slide 

the bracket into the bracket slot in the backside of 

the solar panel. 

The holding bracket holds the weight of the solar 

panel. The direction towards the sunlight can be 

adjusted with the wingnut.

5.2  

Place the pump in the pond or reservoir. Make sure, 

there is enough water in the pond or reservoir. The 

pump need to be fully immersed in water. The pump 

can be placed under water or float on the water sur-

face. Your choise will depend on the water depth and 

type of reservoir used. If the water depth is shallow, 

we suggest the  

under water  

assembly. For  

deeper ponds or  

reservoirs you 

will need to use 

the floating

 

assembly.

Solar panel

Bracket

Tube

Spike

Bracket

1. Pump

2. Pump outlet adaptor

3. 4x Extension tubes

4. LED light

5. Fountain head adaptor

6. 12 Hole daisy jet

7. 7 Hole daisy jet

8. 6 Hole jet

9. Single jet

1

2

3

4

5

6

7

8

9

5.3  Deep water assembly 

(only 

OSLO 300 LIGHT-2)

5.4  Your solar pump kit should look like this after assembly.

IMPORTANT!

Twist plugs slightly and 

pushing it into the sockets. 

Make sure the sealing rings 

are fully in groove

An extra solar 

panel for: 

Oasis 1601R-1, 

Oasis 2002-1 

Fill the net bag with small

stones to act as a ballast

Net bag

Wire

Float

Solar panel

Battery box

Pump

LED light

Solar port (yellow)

Light port (orange)

Pump port (blue)

Wingnut

If there is a rubber bung, lead the cables through it and place it on the 

tube in the corpus to avoid water leakage.

Содержание 5 001 001 008

Страница 1: ...ound online Technische Änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG OASIS 501R 1 5 001 001 008 OASIS 801R 1 5 001 001 009 OASIS 1601R 1 5 001 001 010 OASIS 2002 1 5 001 001 011 1 OSLO 300 LIGHT 2 SP01122 2 de ORIGINAL ...

Страница 2: ...ON We would like to congratulate you on the purchase of our pump We appreciate your trust That s why functional security and operational safety stands on first place for us To prevent damage to persons or property you should read this user manual carefully Please observe all safety precautions and instructions for proper use of the pump Failure to follow the instructions and safety precautions can...

Страница 3: ... water tank must be emp tied rinsed with clean water and stored dry 5 ASSEMBLY INSTRUCTION 5 1 Join the bracket tubes and ground spike together and then attach the solar panel to the bracket Slide the bracket into the bracket slot in the backside of the solar panel The holding bracket holds the weight of the solar panel The direction towards the sunlight can be adjusted with the wingnut 5 2 Place ...

Страница 4: ...aturely strong The batteries are therefore subject to a consumable and wearing part of a shortened warranty of 6 months If you find that the battery will be less efficient the battery needs to be fully charged These allow the unit for 2 to 3 days pump should not be connected standing in the sun in order to allow a maximum charge the battery or use a suitable external charger We recommend to occasi...

Страница 5: ... and the battery to each other with any meta object such as wire l Do not disassemble or modify the battery The battery contains safety and protection devices which may cause the battery to generate heat explode or ignite if damaged l Do not place the battery in or near fire on stoves or other high temperature locations Do not place the battery iiin direct sunlight or use store the battery inside ...

Страница 6: ... 2 Signed for and on behalf of Amur S à r l Remich 08 12 2022 i V Dipl Phys Peter Neumüller Technical Manager 13 GUARANTEE REGULATIONS For all manufacturer defects and material defects we grant the legal guarantee time new and unused product In such cases we take over the exchange or the repair of the pump Forwarding expenses are not carried by us The guarantee is not valid with l Material wear se...

Страница 7: ...chadensminimierung weisen wir Sie hiermit ausdrücklich hin 3 INBETRIEBNAHME l Entnehmen sie alle Teile vorsichtig und kontrollieren Sie diese auf Vollständigkeit Folgende Teile müssen vorhanden sein 1x Pumpe mit 5m Kabel 1x LED Lichtring mit 5m Kabel 1x Batteriegehäuse 1x Fernbedienung enthalten bei OASIS 501R 1 OASIS 801R 1 OASIS 1601R 1 1x Solarpanel mit 2m Kabel 2x Solarpanel bei Oasis 2002 1 O...

Страница 8: ...t HINWEIS Eine höhere Durchflussmenge kostet mehr Leistung und reduziert die Lebensdauer der Batterie 5 1 Verbinden Sie die Halterung die Rohre und die Bodenspit ze und befestigen Sie dann das Solarpanel an der Halte rung Schieben Sie die Halterung in den Klammerschlitz auf der Rückseite des Solarpanels Die Halteklammer hält das Gewicht des Solarpanels Die Richtung zum Sonnen licht kann mit der Fl...

Страница 9: ...er als Verbrauchs und Verschleißteile einer verkürzten Gewährleistung von 6 Monaten Wenn Sie feststellen dass der Akku weniger effizient erscheint muss der Akku neu voll aufgeladen werden Dazu lassen Sie das Gerät für mindestens 8 Stunden Pumpe muß angeschlossen sein in der Sonne stehen um eine maximale Ladung der Batterie zu ermöglichen oder Sie benutzen ein geeignetes externes Lade gerät Wir emp...

Страница 10: ...ithium Ionen Zellen und Akkus können heiß werden explodieren oder sich entzünden und schwe re Verletzungen verursachen wenn sie nicht bestimmungsgemäß eingesetzt werden Bitte beachten Sie unbedingt die unten aufgeführten Sicherheitshinweise l Achten Sie beim Einsetzen der Akkus unbedingt auf die richtige Polarität l Vermeiden Sie daß die positiven und oder negativen Anschlüsse und oder die Pole de...

Страница 11: ...Veränderungen an den Geräten vorgenommen wurden Falls Reparaturen durch eine von uns autorisierte Servicewerkstätte vorgenommen werden haften wir nur insofern wenn Original Ersatzteile und Zubehör verwendet wurden 15 ENTSORGUNGSHINWEISE Elektro Geräte mit dem Symbol der durchgestrichenen Mülltonne dürfen nicht über den Hausmüll entsorgt werden sondern sind an einer Annahmestelle für Recycling von ...

Страница 12: ...ead acid 12V 4Ah Lead acid 12V 4Ah Lead acid 12V 5Ah Cable length Kabellänge 5 m 5 m 5 m Ambient temperature Umgebungstemperatur 0 C 45 C 0 C 45 C 0 C 45 C English Deutsch OASIS 2002 1 5 001 001 011 1 OSLO 300 LIGHT 2 SP01122 2 Pump Max pump capacity Max Fördermenge 1500 l h 300 l h Max pump height Max Förderhöhe 300 cm 120 cm Max fountain height Max Höhe der Fontäne 160 cm 65 cm Max water tempera...

Страница 13: ...for OASIS 501 801 Pumpe 2 für OASIS 501 801 A135 SP03101 Solar panel for OASIS 501R 1 Solarpanel für OASIS 501R 1 A3373 SP02211 Solar panel for OASIS 801R 1 Solarpanel für OASIS 801R 1 A6778 SPZ03142 Solar panel for OASIS 1601 Solarpanel für OASIS 1601 A6781 Solar panel for OASIS 2002 Solarpanel für OASIS 2002 A136 SP03101 LED light ring 4 5x1 7 4V LED Licht Ring 4 5x1 7 4V A6721 SPZ03129 For tech...

Страница 14: ...14 Notes Notizen ...

Страница 15: ...Notes Notizen 15 ...

Страница 16: ...Imprint Impressum Amur S à r l www amur lu Email info amur lu Tel 49 0611 9 45 87 77 0 Fax 49 0611 9 45 87 77 11 de ORIGINAL ...