Appendices
App-6
PL-B900/B910 Series Users Manual
!
!
!
!
!
External Input Signal
The PL’s RAS interface connector uses the following input signals.
Standard Signal Input (DIN)
This standard digital input is used for alarm detection in external devices. The
input signal uses two bits.
The System Monitor utility can be used to enable or disable this feature, as well as
designate what type of processing is to be performed once a signal is received.
Remote Reset Input
This is the reset signal sent from an external device to the PL. When this signal is
enabled, a forced reset of the PL is performed.
The System Monitor utility can be used to enable or disable this feature
External Input Signal (for both DIN and Remote Reset Input)
- External Power
DC12V to DC24V connections are possible
- Input Protection
Protection Diode
- Isolation
Used (photo-isolation)
(Interface Circuit)
(Connection Example)
For connection pin location details,
2.3.5 RAS Interface
Cable
DC12V to
DC24V
External
Power)
Reset Input(+)5pin
DIN0(+) 6pin
DIN1(+) 13pin
(DC12V to DC24V)
Input Port
R
PC357
Reset Input(-)11pin
DIN0(-) 12pin
DIN1(-) 24pin
Dsub 25Pin
Connector
+5V
3.3k
Ω
1/4W
Содержание PL-B900 Series
Страница 12: ...12 PL B900 B910 Series Users Manual Memo...
Страница 38: ...Chapter 2 Specifications 2 18 PL B900 B910 Series Users Manual Memo...
Страница 62: ...Installation and Wiring 4 8 PL B900 B910 Series Users Manual Memo...
Страница 80: ...System Setup 5 18 PL B900 B910 Series Users Manual Memo...
Страница 84: ...PL B900 B910 Series Users Manual 6 4 Memo...
Страница 88: ...7 4 PL B900 B910 Series Users Manual Memo...
Страница 98: ...Appendices App 10 PL B900 B910 Series Users Manual Memo...