background image

3-9

PL B900/B910 Series Users Manual

1) Unscrew the desired expansion

slot’s cover attachment screw, and
remove the cover.
   

  3.1.1, Removing

the Rear Maintenance Cover

Unscrew the Blank Panel’s attach-
ment screw to remove the Blank
Panel.

2) Remove the expansion slot’s duster

cover.

3)  Insert the expansion board into the

expansion slot.

4)  Secure the expansion board’s metal

positioning strip in place with its
attachment screw.

5)  Last, replace the rear maintenance

cover and half cover and secure
them in place with their attach-
ment screws.

Attachment
Screw

Positioning
Strip

3.1.6 Installing an Expansion Board

Содержание PL-B900 Series

Страница 1: ...NT are registered trademarks of the Microsoft Corporation IBM and DOS are registered trademarks of IBM 1 It is forbidden to copy the contents of this manual in whole or in part without the permission...

Страница 2: ...light bodily injury or machine damage can occur Caution Warning Essential Safety Precautions WARNINGS To avoid the possiblity of an electric shock be sure to connect the power cord to the PL before co...

Страница 3: ...r to select an appropriate installation location for the PL Before either plugging in or unplugging a board or inter face connector be sure to turn the PL s power OFF To prevent a possible explosion d...

Страница 4: ...3 seconds before turning it ON again When PL Hard Disk HDD data is lost The Digital Electronics Corporation cannot be held re sponsible or provide any compensation for damage s caused by the loss of d...

Страница 5: ...onnecting the Dual Displays 1 3 1 3 Optional Items 1 4 CHAPTER 2 SPECIFICATIONS 2 1 General Specifications 2 1 2 1 1 Electrical 2 1 2 1 2 Structural 2 1 2 1 3 Environmental 2 2 2 2 Functional Specific...

Страница 6: ...tandard Display DU 6900 DU 7900 3 11 3 1 9 Installing the Display Expansion Board PL PE200 3 12 3 1 10 Connecting an Analog RGB Monitor 3 13 3 1 11 Removing the Cooling Fan Unit 3 14 CHAPTER 4 INSTALL...

Страница 7: ...NANCE AND INSPECTION 7 1 Cleaning the Filter 7 1 7 2 Periodic Maintenance Points 7 3 APPENDICES A 1 Hardware Configuration A 1 A 1 1 I O Mapping A 1 A 1 2 Memory Map A 2 A 1 3 Interrupt Map A 3 A 2 RA...

Страница 8: ...n 1 2 Indicates steps in a procedure Be sure to perform these steps in the order given PL Abbreviation for the PL B900 and PL B910 Series Box Type Industrial Computers DU Standard displayunit for the...

Страница 9: ...signed only for AC100 115V use Any other voltage will require a different cord Floppy Disks 2 PL B910 Series USB Touch Panel Control Utility Disks Floppy Disks 3 PLX900 Series Driver and Utility Disks...

Страница 10: ...date both Digital s own optional boards as well as other commercially available expansion boards Digital also offers a wide variety of optional products such as a 5 12V DC power unit DIM memory module...

Страница 11: ...ate disconnect device and locate it where the operator can easily reach it Danger of explosion if backup battery is incorrectly replaced Replaced only with same or equivalent type recommended by the m...

Страница 12: ...12 PL B900 B910 Series Users Manual Memo...

Страница 13: ...t When connecting Digital s standard display 3 1 8 Connecting the Standard Display When connecting an Analog RGB Monitor 3 1 9 Connecting an Analog RGB Monitor Turn Display ON Install Touch Panel Devi...

Страница 14: ...ker s instal lation manual For system setup and OS installation a PS 2 type keyboard is necessary Since the PL s hard disk drive HDD is a consumable item i e it has a limited lifetime be sure to back...

Страница 15: ...2 5 inch HDD FFD 4 Expansion Slots CD ROM Unit 4 Option PL Main Unit Side Mount 2 FDD Unit RS 232C 3 Ports LPT Connection Cable Attached to Main Unit Standard Display Front Mount 2 FDD Unit LED Analog...

Страница 16: ...two types of installation methods the Star connection or the Daisy Chain connection The performance of any connection method used that is different from those shown below is not guaranteed Star Connec...

Страница 17: ...r Settings Be sure each DU unit s station number is unique PL DU6900 PL DU7900 User Manual 2 3 1 Using Dip Switch for Settings Be sure the display cable is the PL CB200 5M Do not connect more than 2 D...

Страница 18: ...tains two 2 5 inch 2 1GB hard disk drives 5V 12V Power Unit PL PW100 Provides 5Vand 12Vpower to expansion slots Can provide a total of 200mAof current sum of both slots LAN Board DAX IET02 NE2000 comp...

Страница 19: ...u install the Windows NT system If you decide to install the Windows 95 system please use Digital s Windows 95 Touch Panel Device Driver PL ME000 The PL B900 and PL B910 Series units can all use comer...

Страница 20: ...optional PL PW100 power supply should be installed Be sure to use only DIMM modules made by Digital Electronics Corporation Cer tain commercial DIMM modules may fail to meet the PL unit s specificatio...

Страница 21: ...tions 2 Functional Specifications 3 Interface Connector Specifications PL B900 PL B910 PLB901 PL B911 With Fan 5o C to 50o C Ambient Operating Temperature Without Fan 1 5o C to 40o C Storage Temperatu...

Страница 22: ...sized Cover 385mm 15 16in W x 271mm 10 67in H x 162mm 6 38in D excluding projections 385mm 15 16in W x 271mm 10 67in H x 116mm 4 57in D excluding projections Dimensions Including Mirror Disk Unit 330m...

Страница 23: ...only for PL DU 900 via PL CB200 10M or PL CB200 5M Touch Panel COM4 uses Mouse Emulator USB uses USB Touch Panel Driver PL B910 PL B911 COM1 D Sub 9 pin male COM2 D Sub 9 pin male Serial RS 232C w FIF...

Страница 24: ...ply 5V 4A 12V 1A total for 4 slots 5V 2A 12V 0 5A total for 2 slots For the 2nd and 3rd slots on the PL B900 PL B910 and the 2nd slot on the PL B901 PL B911 either a PCI or an ISA type expansion board...

Страница 25: ...n G R signal GND 8 Return B R signal GND 9 Reserved NC 10 GND Digital signal ground 11 Reserved NC 12 Reserved NC 13 H SYNC Horizontal signal Input 14 Y SYNC Vertical signal input 15 Reserved NC 6 4 2...

Страница 26: ...1 25 24 23 22 21 20 19 18 17 16 15 14 Pin No SPP ECP Mode Signal Name EPP Mode Signal Name Direction Electrical Specif Pin No SPP ECP Mode Signal Name EPP Mode Signal Name Direction Electrical Specif...

Страница 27: ...D Sub 25 pin Male 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 2 3 6 RAS Interface For detailed RAS Feature information Appendix 2 RAS Feature Interface Circuit Connection Exampl...

Страница 28: ...tor SST3904 DOUT pin 7 Alarm Output pin 9 Lamp Output pin 21 DOUT pin 8 Alarm Output pin 10 Lamp Output pin 22 5V 4 7k Output External Output Signal DOUT Alarm Output Lamp Output Port Output Specifati...

Страница 29: ...These RS 232C interfaces D sub 9 pin male connectors allow communication with other computers and connection to peripheral devices F Printer Connector LPT1 Centronics standard interface D sub 25 pin...

Страница 30: ...Reset Switch Pushing this switch resets the PL S Standard Display Connector GVIF OUT Used to connect Digital s Standard Display Cable PL CB200 M T Standard USB Connector USB This interface is USB 1 0...

Страница 31: ...emoved X Analog RGB Connector Cover Provides an analog RGB interface Remove this cover when attaching an RGB CRT monitor to the PL Y Filter Cover Remove this cover when cleaning or removing the PL s c...

Страница 32: ...al Dimensions 2 5 1 PL B900 B910 Series External Dimensions 310 12 20 271 10 67 330 12 99 PL B900 PL B910 4 slot type 49 1 93 162 6 38 252 9 92 PL B900 PL B910 49 1 93 162 6 38 252 9 92 105 4 4 15 Ope...

Страница 33: ...pecifications 2 13 PL B900 B910 Series Users Manual PL B901 PL B911 2 slot type 116 4 57 116 4 57 PL B901 PL B911 310 12 20 330 12 99 252 9 92 252 9 92 49 1 93 49 1 93 271 10 67 Unit mm in excluding p...

Страница 34: ...257 252 10 10 9 10 19 4 49 6 273 Attachment Holes 38 92 92 330 Attachment Holes PL B901 PL B911 2 slot type Attachment Bracket Attachment Holes Detail 49 257 252 10 10 9 10 19 4 273 38 92 92 330 310...

Страница 35: ...on should be given to the PL s weight 2 1 3 Environmental Be sure all installation tolerances are maintained to prevent the unit from falling out of its installation panel Drilling Attachment Bracket...

Страница 36: ...2 5 3 Full Sized Cover Mirror Disk Unit Attachment Dimensions Full sized cover 166 Mirror Disk Unit PL B901 PL B911 2 slot type 116 252 159 49 271 55 330 Full sized cover 106 166 Mirror Disk Unit Ther...

Страница 37: ...hat the PL is mounted in its attachment panel cabinet Due to dimension differences the PL FC200 or a full sized expansion board can not be attached prior to installing the PL into a panel When using a...

Страница 38: ...Chapter 2 Specifications 2 18 PL B900 B910 Series Users Manual Memo...

Страница 39: ...ve unit PL DK200 Display Expansion Board PL PE200 Special Display PL DU6900 PL DU7900 and the PL s cooling fan For information about the installation of other option units please refer to those unit s...

Страница 40: ...to hold the rear main tenance cover and half cover 3 Pivot the half cover open and lift up slightly to free the guide tabs Next remove the half cover Be sure to handle the rear maintenance cover caref...

Страница 41: ...Maintenance Cover 1 Unscrew the four 4 attachment screws used to hold the rear mainte nance cover and half cover 2 Pivot the half cover open and slide the cover slightly to the side to free the guide...

Страница 42: ...ts socket press down on the socket s ejector tabs to release the module 1 Install the DIM expansion module in the empty socket Positioning pins Positioning grooves Empty Socket Built in DIM Module Sin...

Страница 43: ...2 Insert the FDD unit so that its guide grooves fit the slot s guide ways Push the unit in until its rear con nector is connected securely 3 Secure the unit in place with its two 2 attachment screws...

Страница 44: ...nstalling the FDD Unit PL FD210 The PL FD 210 can only be used with the PL B900 and PL B910 4 slot type units and cannot be used with the PL B901 and PL B911 2 slot type units The PL FD200 and the PL...

Страница 45: ...screws 6 Fix the unit in place with its two 2 attachment screws 7 Last replace the Blank Panel re moved in step 3 Push up 5 Insert the FDD unit so that its guide grooves fit the chassis holder s guid...

Страница 46: ...ected 4 Fix the unit in place with its two 2 attachment screws Reattach the Expansion Slot cover us ing the same steps The following insertion removal procedure is applicable also to the FFD PL FF200...

Страница 47: ...screw to remove the Blank Panel 2 Remove the expansion slot s duster cover 3 Insert the expansion board into the expansion slot 4 Secure the expansion board s metal positioning strip in place with its...

Страница 48: ...able to the PL s IDF I F connector Be sure that the cable is securely connected before turning ON the PL s power switch 1 Unscrew the two 2 IDF I F cover at tachment screws and remove the cover PL B90...

Страница 49: ...will prevent damage to the PL and the accidental cut ting of any of its power cord terminals 4 Reattach Cover A and secure it in place with its two 2 Attachment Screws 3 After checking that the PL an...

Страница 50: ...L s Standard Display connector to the DU unit s connector When using 2 DU units Use the Standard Display Cable 5m to connect the PL s Display Expansion Board connector to the DU unit s connector Daisy...

Страница 51: ...unit For conenction details FP 570 Series User Manual When the FP is connected to a PL B910 PL B911 PL B910 series unit the touch panel cannot be used only the display When the FP is used the user s s...

Страница 52: ...s ambient temperature to rise 2 1 2 Environment Specifications 3 1 11 Removing the Cooling Fan Unit PL B900 PLB910 Unit 1 Remove the cooling filter cover s at tachment screw 2 Remove the cooling filt...

Страница 53: ...Metal Plate Fan unit Power Cable Connector 6 Unscrew the two 2 fan unit s attach ment screws and remove the fan unit from the metal plate holding the fan unit 7 Attach the metal plate and the cooling...

Страница 54: ...take out the fan unit 4 Unplug the fan unit s power cable connector from the PL 5 Unscrew the two 2 attachment screws and remove the fan unit and then remove the fan unit from the metal plate 6 Secur...

Страница 55: ...rature sen sor in the location shown in the left side drawing If this area s temperature exceeds the allowed limit a machine breakdown can occur Also be sure that the panel s viewing angle is tilted n...

Страница 56: ...crash or malfunc tion When using a fan to cool the PL unit be sure that the fan does not point directly at any of the PL s disk drive units since it can lead to a hard disk crash or malfunction Avoid...

Страница 57: ...re to follow the di mensions given for the attachment holes 2 5 3 Full Sized Cover Attachment Dimensions 3 Attach the PL to the Installation Panel with M4 screws First insert the main unit attachment...

Страница 58: ...3 Power Terminals Power Switch POWER I o I ON o OFF PL B900 Unit 4 3 Wiring the PL 4 3 1 Connecting the Power Cord Connect the PL s power cord to the PL s rear face power terminals Use the following s...

Страница 59: ...e with the PL This power cable is designed only for AC100V 115V use When using other than AC100V 115V power use a cable that is designed spe cifically for that level of power FG L N FG L N Black White...

Страница 60: ...cord Isolatethemaincircuit highvoltage large current line I O signal lines and power cord and do not bind or group them to gether To prevent damage from lightning con nect a lightning surge absorber...

Страница 61: ...hem through conduits c Shared ground not allowed PL PL Other device Other device Other device PL 1 Use a grounding resistance of less than 100 and a 2mm2 or thicker wire or your country s applicable s...

Страница 62: ...Installation and Wiring 4 8 PL B900 B910 Series Users Manual Memo...

Страница 63: ...s a summary of the keyboard keys used to carry out the set up SYSTEM SETTING SELECTION AREA Each of the titles areas listed here contains system setting items STANDARD CMOS SETUP BIOS FEATURES SETUP C...

Страница 64: ...me This data sets the PL s internal time and date Hours 00 23 Minutes 00 59 Seconds 00 59 Drive C This data sets the IDE hard disk s parameters When this setting is set to AUTO the hard disk s paramet...

Страница 65: ...nd recommended for most users Halt On Designates the type of processing that will be performed when an error occurs during the Initial Start Up s Self Test The All But Disk Key selection is factory se...

Страница 66: ...nates whether a warning message appears when an error occurs during a write to the Hard Disk s Boot Sector The two selections are Disabled and Enabled The Disabled selection is factory set and recomme...

Страница 67: ...the repeat mode for characters on the keyboard The selections Disabled and Enabled are available Disabled is factory set and recommended for most users Typematic Rate Chars Sec When Enabled is selecte...

Страница 68: ...SET FEATURES SETUP menu item calls up the following screen Bank 0 1 DRAM Timing 70ns SDRAM Cycle Length 3 DRAM Read Pipeline Enabled Sustained 3T Write Enabled Cache Rd CPU Wt Pipeline Enabled Cache T...

Страница 69: ...Fast is factory set and recommended for most users Video BIOS Cacheable Designates if the cache performs on the Video BIOS The available selections are Enabled and Disabled Enabled is factory set and...

Страница 70: ...Horizontal synchronous signal select V H SYNC Blank To turn off the display only select Blank Screen Select DPMS support when the CRT display is supported by DPMS V H SYNC Blank is factory set and rec...

Страница 71: ...driven in the VGA port The available selections are ON and OFF OFF is factory set and recommended for most users LPT COM Designates if the system is turned on when any event is driven in the serial po...

Страница 72: ...tion is factory set and recommended for most users CPU to PCI Write Buffer Enabled PCI Dynamic Bursting Enabled PCI Master 0 WS Write Enabled PCI Delay Transaction Enabled PCI Master Read Prefetch Ena...

Страница 73: ...o Manual can the following IRQ 3assigned to IRQ 15assigned to settings be changed These settings are used for the PCI ISA PnP and Legacy ISA items PCI ISA PnP Used for PCI or ISA s PnP Card Legacy ISA...

Страница 74: ...system settings It is normally not used CPU Warning Temperature Disabled System Warning Temp Disabled Power FAN Tolerance Disabled CPU FAN Tolerance Disabled IN0 Vcore Tolerance Disabled IN2 3 3V Tol...

Страница 75: ...Sets the allowable range for the PL s power supply fan Disabled 30 and 50 are available The Disabled selection is factory set and recommended for most users INO Vcore Sets the allowable range for the...

Страница 76: ...two selections available are Disabled and Enabled The Enabled selection is factory set and recommended for most users IDE Prefetch Mode Designates if the IDE drive s high speed access is performed by...

Страница 77: ...s the PL s Serial Port1 address setting The selections include Disabled Auto 3F8 IRQ4 2F8 IRQ3 3E8 IRQ4 or 2E8 IRQ3 The 3F8 IRQ4 selection is factory set and recommended for most users Onboard Serial...

Страница 78: ...ocation numbers The selections include IRQ3 IRQ4 IRQ9 IRQ10 or IRQ15 Onboard Serial Port 4 Designates the PL s Serial Port 4 which is internally connected to the touch panel address setting The select...

Страница 79: ...UTO DETECTION CYLS HEADS PRECOMP LANDZONE SECT0RS MODE Drive C Mb Note Some OSes like SCO UNIX must use NORMAL for Installation ROM PCI ISA BIOS 2A5IIU1C CMOS SETUP UTILITY AWARD SOFTWARE INC Select D...

Страница 80: ...System Setup 5 18 PL B900 B910 Series Users Manual Memo...

Страница 81: ...ly for the PL B910 PL B900 and a PS 2 compatible keyboard 6 1 Setting Up Your PL OS 6 1 Setting Up Your PL OS Chapter 6 OS Setup Be sure to read the Driver and Utility Disk README documents prior to u...

Страница 82: ...tallation The README file contains the following information 6 1 1 Touch Panel Device Driver Settings When using Digital s Standard Disply or the FP 570 display the following touch panel drivers will...

Страница 83: ...e unselected Sound Select check mark Button simulation Left Advanced Settings Miscellaneous Swap X Y Leave unselected Initialize Leave unselected Hardware Controls Serial COM Port When connecting the...

Страница 84: ...PL B900 B910 Series Users Manual 6 4 Memo...

Страница 85: ...on SinceexcessivedirtanddustinthefilterofthePL scoolingfancanpotentiallyaffectthe performanceoftheunit regularinspectionandcleaningofthefilterisstronglyrecom mended PL B900 PL B910 Unit 1 Unscrew the...

Страница 86: ...ve the filter in direct sunlight 4 After reattaching the filter to the filter cover reattach the cover to the cooling unit with the cover attachment screw Filter 3 Clean the filter completely Ifstubbo...

Страница 87: ...RH to 85 RH Is the atmosphere free of corrosive gas Electrical specifications check Is the voltage adequate AC85V to AC265V 50 60 Hz Installation check points Is the connection cable firmly connected...

Страница 88: ...7 4 PL B900 B910 Series Users Manual Memo...

Страница 89: ...rd Controller 0070H 007FH Real time clock NMI mask 0080H 009FH DMApage register 00A0H 00BFH Interrupt controller 2 8259A 00C0H 00DFH DMAcontroller 2 8237 00F0H 00FFH Numeric data processor 01F0H 01FFH...

Страница 90: ...Series Users Manual FFFF0000H 00100000H 000E0000H 000A0000H 000C0000H 000CC000H FFFFFFFFH 00000000H System ROM Unused RAM System ROM Expanded ROM Area VGA BIOS Display Adaptor Unused RAM 640 KB Syste...

Страница 91: ...IRQ 6 Floppy Disk Controller IRQ 7 Parallel Port 1 LPT1 Printer Port IRQ 8 Real Time Clock IRQ 9 Serial Port 3 COM3 General Use Port IRQ 10 Serial Port 4 COM4 Touch Panel for Standard monitor IRQ 11...

Страница 92: ...es are supported External Output Signal Standard Signal Output DOUT 1 bit Alarm Output 1 point Lamp Output 1 point Types of Processing all units LED Indicator 3 state display 1 point Pop up Message Ou...

Страница 93: ...mentioned features as well as designate what type of processing is to be performed Watchdog Timer Time Up This feature alternately writes Time Up Count values from the CPU to the RAS feature s specia...

Страница 94: ...his is the reset signal sent from an external device to the PL When this signal is enabled a forced reset of the PL is performed The System Monitor utility can be used to enable or disable this featur...

Страница 95: ...digital output signals provide system condition information to external devices The System Monitor utility can be used to enable or disable any of these output signals Also when alarm output is enable...

Страница 96: ...the Windows system s pop up message feature to indicate that an alarm has occurred Buzzer Output This feature uses the PL s internal speaker to indicate the system s condition System Shutdown This fea...

Страница 97: ...rocessing Enable Disable Settings Outout Settings Cooling Fan RPM Alarm Int Temp Alarm CPU Clear Time Up Buzzer Output Pop Up Message Alarm Alarm Alarm RAS Connector General Purpose Input Remote Reset...

Страница 98: ...Appendices App 10 PL B900 B910 Series Users Manual Memo...