PROEL PC260 Скачать руководство пользователя страница 15

15

Recall a Preset

To recall a preset, press the front panel RCL button . The display shows the 

RECALL PRESET menu and the current preset in the list of those available 

in the internal memory . Using the DATA knob scroll the preset list and select 

the preset to be recalled . Valid presets will display the preset name, empty 

presets will not display any name . Select a valid preset and push the DATA 

knob to confirm .

The display will prompt, “Push DATA to confirm, ESC to abort” . Press the DATA 

knob to confirm and load the new preset .

IMPORTANT: Make sure that the new preset is appropriate for 

your system, and that the connections to your system are correct 

for the current configuration. Failure to do so could cause 

unexpected results or damage to the system or its components.

To exit the Recall process without loading a new preset, press the ESC button, 

SETUP or any active buttons in the processing menu . ESC button will return 

the display to run-time mode . Setup or any active processing menu buttons 

will display the corresponding edit screen .

Save a Preset

Edited presets can be saved in one of the User Preset memory locations . 

To save a preset, press the SAVE button . The display will show the SAVE 

PRESET menu . If the previosly loaded preset was a user preset the cursor 

starts from the same user preset . If the previously loaded preset was 

factory preset the cursor starts from the first user preset . Use the DATA knob 

to select the user destination . Locations that already have presets saved in 

them will display a preset name . Empty locations will display “default” in the 

name field . You may select an empty location, or a location of a preset that 

will be over-written and push the DATA knob to confirm .

The display will prompt, “Push DATA to confirm, ESC to abort” . Press the DATA 

knob to confirm and save the new preset .

Now you have to enter a name: Rotate the DATA knob to select the letter or 

symbol, then push the DATA knob to skip to the next character in the name 

field . The PC260 provides the complete ANSI character set, in this order:

!"#$%&'()*+,-./0123456789:;<=>?@ 

ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]^_` 

abcdefghijklmnopqrstuvwxyz{|}~

When the preset is named, press SAVE again .

To exit the Save process without saving a new preset, press the ESC button, SETUP or any active buttons on processing menu . ESC 

button will return the display to run-time mode . Setup or any active processing menu buttons willdisplay the corresponding edit screen .

Delete a Preset

Also if doesn't happen very often, sometimes could be necessary to erase a preset, particularly when using the PRESET LOCK mode 

or the SPL manager and you need to cancel previously stored preset that rae not used anymore .

To erase a preset you have to recall the "Default" preset (no. 1) and save it in the user location you want to erase:

Содержание PC260

Страница 1: ...USER S MANUAL ENGLISH www proel com...

Страница 2: ...2...

Страница 3: ...Cables 13 Balanced Input Output Connections Recommended 13 Un balanced Input Output Connections Not recommended 13 Digital Input AES EBU Connection 13 USB Cable 13 PRONET Cable 13 OPERATING MODE 14 R...

Страница 4: ...o comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is ope...

Страница 5: ...rowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to const...

Страница 6: ...ld result in some hearing loss To ensure against potentially dangerous exposure to high sound pressure levels it is recommended that all persons exposed to equipment capable of producing high sound pr...

Страница 7: ...nels Absolutely do not obstruct the ventilation holes Blocked ventilation can cause damages and fire Do not locate sensitive high gain equipment such as mixer preamplifiers recorders or AD DA conversi...

Страница 8: ...8 OVERVIEW USB PORT display preset recall and save page scroll data value select and input mains ac power output connections pronet network connections terminate button digital audio input...

Страница 9: ...9 PROCESSING MENU ESCAPE BUTTON CHANNEL SELECT BUTTONS CHANNEL MUTE BUTTONS LED METERS EXTERNAL MIC INPUT FOR RTA output connections ground lift button input pad button input connections...

Страница 10: ...al Failure to do so may result in improper performance loss or injury CONTROLS AND CONNECTIONS FRONT PANEL 1 USB port USB port for connection to a PC running Windows XP Vista Seven 32 or 64 bit Using...

Страница 11: ...s so the Clip red LED should never light If the PC260 s input does clip reduce the output level of the connected mixer The 6dB PAD button at the rear panel can be used for adjusting the input level al...

Страница 12: ...ong distance or multiple unit applications See PRONET section further in this manual 21 PRONET Network IN connector This is a standard RJ45 CAT5 connector with optional NEUTRIK NE8MC RJ45 cable connec...

Страница 13: ...nectors these are high quality connectors and are compatible with standard RJ45 plugs Node connections are made using standard RJ45 connectors and CAT5 cable Long runs should be solid core but standar...

Страница 14: ...s The PC260 comes with Factory presets including the settings for PROEL loudspeaker systems A factory preset is identified by a F letter after the number Only the the input processing parameters can b...

Страница 15: ...om the same user preset If the previously loaded preset was a factory preset the cursor starts from the first user preset Use the DATA knob to select the user destination Locations that already have p...

Страница 16: ...meters per second V is the speed of sound and T is the temperature of the air This formula finds the average speed of sound for any given temperature celcius The speed of sound is also affected by oth...

Страница 17: ...b Press SETUP again for confirming all data Press ESC or PG UP DW buttons to escape from this page without changing the lock status FULL EDIT This is the defult LOCK level when you turn on the PC260 f...

Страница 18: ...ue is present only in the output channels and can be set between 6dB to 6dB This parameter can be adjusted also if the PC260 unit is in PARTIAL lock status The PHASE value can be set between 0 normal...

Страница 19: ...us slopes with the FREQ parameter set at 1 kHz FREQ Frequency offers a selectable frequency range from 20 Hz to 20 KHz DELAY PC260 offers input and output delay Master A and B input delay is useful fo...

Страница 20: ...the response TYPE of the equalizer by changing the shape or Q of the single cells The behaviour of each type is shown below The EZCurve type is based on the Proel s EZCurve analog Graphic Equalizer s...

Страница 21: ...ignal passes thru the filter cell unchanged Please note that changing the filter TYPE the gain parameter goes to zero this avoids excessive sound changes during a performance Attention must be paid to...

Страница 22: ...a typical band pass filter with 6dB slope Note that the response is fundamentally NOT a flat topped response so it is not constructed from a high pass and low pass The graph shows the response at 1KHz...

Страница 23: ...e first page of the filter MODE SIDECHAIN and BYPASS are in the second page The first page shows also the input LEVEL meter and the second page the GAIN meter When Input A and Input B channels are lin...

Страница 24: ...ogram and set an appropriate threshold level GAIN METER The GAIN meter shows the amount of gain reduction of the filter Depending on how the filter MODE is set ABOVE BELOW you can see the filter actio...

Страница 25: ...ust them if some audible artefacts are noted MODE This parameter is used to set the dynamic processor as compressor Comp or limiter Lim When it is set as limiter the RATIO parameter is not available b...

Страница 26: ...the speaker in order to avoid the signal clipping an event that can seriously damage or destroy a speaker 4 A typical professional amplifier has two operating modes that can be selected by a switch i...

Страница 27: ...Press the SPLM button to access the first page of the Sound Pressure Level Management where you can select the PROGRAM to edit or activate using the DATA knob rotate press In the following page use ag...

Страница 28: ...and A XLR balanced cable the lenght depends by the distance between the measurement mic and the PC260 A track with a pink noise record pink noise is a special random noise where each octave carries an...

Страница 29: ...ed live or disco system PC260 2 x 2 xover 1 zone advanced live or disco pub system L R L L L L high mid low R R R high mid low amp1 1 2 1 2 amp2 1 2 1 2 1 2 1 2 amp3 LOW sub out MID sat out HIGH sat o...

Страница 30: ...the Driver folder within the Pronet application folder by default is C Program Files Proel Pronet Driver or if you changed it your path Driver Please refer also to Installation and Drivers paragraphs...

Страница 31: ...device in a Pronet network you have to re set correctly the termination Note 2 Each device is issued from the PROEL factory has ID 1 Often also a device that returns from a technical assistance cente...

Страница 32: ...mentation When you connect the converter to the USB port of the PC the LED on the top lights RED this mean that it is powered but the converter is not working yet The first time you go online the Pron...

Страница 33: ...R SIDE 4 REMOVE THE OLD BATTERY USE A PLASTIC TOOL TO LIFT UP THE POSITIVE CONTACT 5 PLACE THE NEW BATTERY INSTEAD THE OLD ONE IMPORTANT AT THIS POINT ALWAYS FOLLOW CAREFULLY THESE TWO STEPS IN ORDER...

Страница 34: ...to 15 dB in 0 2 dB steps Q bandwidth 0 4 to 28 85 3 to 0 05 1 20 oct steps EQ freq 15 6 Hz 22 62 kHz 1 20 oct steps Dynamic EQ filters Maximum number of filters 3 per input Parameters EQ Param Shelf...

Страница 35: ...79 6 156 7544 3772 1886 943 15016 7508 3754 17 14 79 5 487 5992 2996 1498 749 11927 5964 2982 16 13 79 4 890 4760 2380 1190 595 9474 4737 2369 15 12 79 4 358 3781 1890 945 473 7526 3763 1881 14 11 79...

Страница 36: ...www proel com PROEL S p A World Headquarters Factory Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 REV 30 13 CODE 96MAN0040...

Отзывы: