PROEL PC260 Скачать руководство пользователя страница 12

12

14. RTA MIC input

This balanced XLR input is fitted a phantom power to supply and it can be used for connecting a condenser microphone for acoustic 

measurements . This allows the PC260 to measure and display in real time the signal reproduced through the speakers system in the 

acoustic environment .

REAR PANEL

15. AC ~

The PC260 features a standard IEC A .C . inlet that will accept universal power cords . The PC260 power supply is auto-ranging and can 

accept voltages from 100 - 240 V AC, 50 – 60 Hz . Only A .C . cords approved for use in your country should be connected to the PC260 .

16. FUSE holder

The A .C . inlet includes a fuse holder that contains the mains fuse as well as a spare fuse . If necessary, replace the fuse only with a 

specified 5x20mm, T 1 A 250 V replacement . Disconnect A .C . power before replacing a fuse . Before turning the unit back on, assess 

the condition of the A .C . receptacle powering the unit . If the fuse continues to blow, refer to PROEL qualified service personnel .

17. POWER switch

The A .C . power switch turns power to the PC260 On and Off .

18. AES/EBU Digital Input

In addition to the analog audio inputs, an AES/EBU digital stereo input is provided and selectable in the SETUP menu . The input 

conforms to IEC standard 60958 Type I . Connections must be made with three-conductor, 110-Ohm, twisted pair cabling and an XLR 

connector . It allows to use all sampling frequencies in the range of 32-96 kHz .

19. TERMINATE switch

In a PRONET network the last connected device must be terminated (with an inner load resistance) especially in a long run cabling: 

press this switch if you want to terminate the unit .

20. PRONET Network OUT connector

This is a standard RJ45 CAT5 connector (with optional NEUTRIK NE8MC RJ45 cable connector carrier), used for transmission of remote 

control data over long distance or multiple unit applications . See PRONET section further in this manual .

21. PRONET Network IN connector

This is a standard RJ45 CAT5 connector (with optional NEUTRIK NE8MC RJ45 cable connector carrier), used for transmission of remote 

control data over long distance or multiple unit applications . See PRONET section further in this manual .

22. Balanced XLR Output connectors

Each output channel has an electronically balanced XLR connector for the connection to the system's amplifiers .

IMPORTANT:

 Care must be taken to assure that each output is connected to an appropriate amplifier and loudspeaker to 

avoid damage or unexpected results . Note that a new preset may change the assignment of channel and its frequency 

range . For instance an output assigned to Hi frequency speakers in one preset, may be assigned as a sub output in another . 

See Configurations section further on this manual .

23. Balanced XLR Input connectors

Each input has an electronically balanced, locking XLR connector . In stereo or dual modes, connections to both inputs must be made . 

In mono modes, only one connection is needed, typically to Input A .

24. Balanced XLR Thru connectors

Each analog audio input is linked directly to an XLR male connector . The signal does not undergo any digital conversion or processing . 

These connectors are used to pass input audio to a second PC260 used as a slave or to other audio inputs in the system .

25. – 6dB PAD switch

Input levels to the PC260 can be reduced by 6dB prior to the A/D converter to compensate for higher-level output from mixers and 

other audio devices . The PC260‘s Input level Meters (8) will indicate incoming signal level and whether attenuation is required .

26. GND LIFT switch

This switch lift the ground of the balanced audio inputs from the earth-ground of the PC260 . If you have HUM noise problem on the 

whole loudspeaker system attached to your PC260 try to change the position of this switch . Please note that to have an effect all 

cables must be balanced .

Содержание PC260

Страница 1: ...USER S MANUAL ENGLISH www proel com...

Страница 2: ...2...

Страница 3: ...Cables 13 Balanced Input Output Connections Recommended 13 Un balanced Input Output Connections Not recommended 13 Digital Input AES EBU Connection 13 USB Cable 13 PRONET Cable 13 OPERATING MODE 14 R...

Страница 4: ...o comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is ope...

Страница 5: ...rowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to const...

Страница 6: ...ld result in some hearing loss To ensure against potentially dangerous exposure to high sound pressure levels it is recommended that all persons exposed to equipment capable of producing high sound pr...

Страница 7: ...nels Absolutely do not obstruct the ventilation holes Blocked ventilation can cause damages and fire Do not locate sensitive high gain equipment such as mixer preamplifiers recorders or AD DA conversi...

Страница 8: ...8 OVERVIEW USB PORT display preset recall and save page scroll data value select and input mains ac power output connections pronet network connections terminate button digital audio input...

Страница 9: ...9 PROCESSING MENU ESCAPE BUTTON CHANNEL SELECT BUTTONS CHANNEL MUTE BUTTONS LED METERS EXTERNAL MIC INPUT FOR RTA output connections ground lift button input pad button input connections...

Страница 10: ...al Failure to do so may result in improper performance loss or injury CONTROLS AND CONNECTIONS FRONT PANEL 1 USB port USB port for connection to a PC running Windows XP Vista Seven 32 or 64 bit Using...

Страница 11: ...s so the Clip red LED should never light If the PC260 s input does clip reduce the output level of the connected mixer The 6dB PAD button at the rear panel can be used for adjusting the input level al...

Страница 12: ...ong distance or multiple unit applications See PRONET section further in this manual 21 PRONET Network IN connector This is a standard RJ45 CAT5 connector with optional NEUTRIK NE8MC RJ45 cable connec...

Страница 13: ...nectors these are high quality connectors and are compatible with standard RJ45 plugs Node connections are made using standard RJ45 connectors and CAT5 cable Long runs should be solid core but standar...

Страница 14: ...s The PC260 comes with Factory presets including the settings for PROEL loudspeaker systems A factory preset is identified by a F letter after the number Only the the input processing parameters can b...

Страница 15: ...om the same user preset If the previously loaded preset was a factory preset the cursor starts from the first user preset Use the DATA knob to select the user destination Locations that already have p...

Страница 16: ...meters per second V is the speed of sound and T is the temperature of the air This formula finds the average speed of sound for any given temperature celcius The speed of sound is also affected by oth...

Страница 17: ...b Press SETUP again for confirming all data Press ESC or PG UP DW buttons to escape from this page without changing the lock status FULL EDIT This is the defult LOCK level when you turn on the PC260 f...

Страница 18: ...ue is present only in the output channels and can be set between 6dB to 6dB This parameter can be adjusted also if the PC260 unit is in PARTIAL lock status The PHASE value can be set between 0 normal...

Страница 19: ...us slopes with the FREQ parameter set at 1 kHz FREQ Frequency offers a selectable frequency range from 20 Hz to 20 KHz DELAY PC260 offers input and output delay Master A and B input delay is useful fo...

Страница 20: ...the response TYPE of the equalizer by changing the shape or Q of the single cells The behaviour of each type is shown below The EZCurve type is based on the Proel s EZCurve analog Graphic Equalizer s...

Страница 21: ...ignal passes thru the filter cell unchanged Please note that changing the filter TYPE the gain parameter goes to zero this avoids excessive sound changes during a performance Attention must be paid to...

Страница 22: ...a typical band pass filter with 6dB slope Note that the response is fundamentally NOT a flat topped response so it is not constructed from a high pass and low pass The graph shows the response at 1KHz...

Страница 23: ...e first page of the filter MODE SIDECHAIN and BYPASS are in the second page The first page shows also the input LEVEL meter and the second page the GAIN meter When Input A and Input B channels are lin...

Страница 24: ...ogram and set an appropriate threshold level GAIN METER The GAIN meter shows the amount of gain reduction of the filter Depending on how the filter MODE is set ABOVE BELOW you can see the filter actio...

Страница 25: ...ust them if some audible artefacts are noted MODE This parameter is used to set the dynamic processor as compressor Comp or limiter Lim When it is set as limiter the RATIO parameter is not available b...

Страница 26: ...the speaker in order to avoid the signal clipping an event that can seriously damage or destroy a speaker 4 A typical professional amplifier has two operating modes that can be selected by a switch i...

Страница 27: ...Press the SPLM button to access the first page of the Sound Pressure Level Management where you can select the PROGRAM to edit or activate using the DATA knob rotate press In the following page use ag...

Страница 28: ...and A XLR balanced cable the lenght depends by the distance between the measurement mic and the PC260 A track with a pink noise record pink noise is a special random noise where each octave carries an...

Страница 29: ...ed live or disco system PC260 2 x 2 xover 1 zone advanced live or disco pub system L R L L L L high mid low R R R high mid low amp1 1 2 1 2 amp2 1 2 1 2 1 2 1 2 amp3 LOW sub out MID sat out HIGH sat o...

Страница 30: ...the Driver folder within the Pronet application folder by default is C Program Files Proel Pronet Driver or if you changed it your path Driver Please refer also to Installation and Drivers paragraphs...

Страница 31: ...device in a Pronet network you have to re set correctly the termination Note 2 Each device is issued from the PROEL factory has ID 1 Often also a device that returns from a technical assistance cente...

Страница 32: ...mentation When you connect the converter to the USB port of the PC the LED on the top lights RED this mean that it is powered but the converter is not working yet The first time you go online the Pron...

Страница 33: ...R SIDE 4 REMOVE THE OLD BATTERY USE A PLASTIC TOOL TO LIFT UP THE POSITIVE CONTACT 5 PLACE THE NEW BATTERY INSTEAD THE OLD ONE IMPORTANT AT THIS POINT ALWAYS FOLLOW CAREFULLY THESE TWO STEPS IN ORDER...

Страница 34: ...to 15 dB in 0 2 dB steps Q bandwidth 0 4 to 28 85 3 to 0 05 1 20 oct steps EQ freq 15 6 Hz 22 62 kHz 1 20 oct steps Dynamic EQ filters Maximum number of filters 3 per input Parameters EQ Param Shelf...

Страница 35: ...79 6 156 7544 3772 1886 943 15016 7508 3754 17 14 79 5 487 5992 2996 1498 749 11927 5964 2982 16 13 79 4 890 4760 2380 1190 595 9474 4737 2369 15 12 79 4 358 3781 1890 945 473 7526 3763 1881 14 11 79...

Страница 36: ...www proel com PROEL S p A World Headquarters Factory Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 REV 30 13 CODE 96MAN0040...

Отзывы: