30
The
CONF MASTER EQUALIZER
menu allows you to view and configure the
equalisation parameters of the system audio output.
You can configure treble, medium and bass tones; configurable values are expressed in
decibels referred to 0dB.
The configurable values for each band are:
-15dB, -12 dB, -10 dB, -8 dB, -6 dB, -4 dB, -2 dB, -1 dB, 0 dB, +1 dB, +2 dB, +4 dB, +6 dB,
+8 dB, +10 dB, +12 dB, +15 dB
To configure an equalisation value, simply press OK to access the
Master equalizer set
configuration screen.
Select the band to be changed with the RIGHT and LEFT arrows and select the desired
value with the UP and DOWN arrows. To confirm the configuration press OK; to cancel
the changes, press
BACK
. The configured values are applied in real time during
parameter editing.
To change the system equalization you must have access level 2, if not a screen is
displayed where you are required to login to carry out this operation.
The
DELETE SYSTEM LOGS
menu allows you to delete all
Logs
system events; to
complete the operation, simply press OK; to cancel press
BACK
.
To perform this operation you must be logged in at access level 2, otherwise a POP-UP
will appear indicating the need to login at access level 2 to complete the operation.
NOTE:
The deletion of all
Logs
will empty the list of recorded events and will write a
Log
deletion event.
The
SYSTEM INFO
menu displays the system information:
Mfg:
System manufacturer
EC Cert:
CE certificate number
Firmware:
Version of the uploaded software
Up-Time:
On time (dd - days / hh - hours / mm - minutes)