19
5.
Led Level indicator - Vu meter
It indicates the output signal level . For a correct amplifier volume use, the volume level must be set
between –20 dB e 0 dB and when the first five leds are on. If such level makes lighting only the first 2
leds (+3 dB +6 dB), the output signal could be distorted the volume then must be reduced.
6.
Digital Radio Module
7.
ON/OFF Switch for Radio Section
8.
Radio volume control
9.
CD/MP3 player module
10.
CD housing
11.
USB Input
12.
Brackets for 19” rack housing purposes”
13.
Handle
3. REAR PANEL CONTROL
fig. 2
1.
Main Power supply plug ( with fuse)
2.
Protection Fuse
It protects the unit against eventual power supply voltage variation. It can be replaced .
3.
Main power supply voltage selector 230/117Vca 50/60Hz
4.
Inputs INPUT1 ~ INPUT4:
a. COMBO/XLR Input connector
b. Euro block terminal – can be removed
c. Dip-switch:
PIN1
position ON=Input for a signal- Micro level
position OFF=input for a signal-.LINE level
PIN2
position ON = Input direction is inverted
PIN3
position ON = High pass filter – active in input (ideal for speech)
position OFF = on input no filter action
PIN4
position ON = Phantom 48V active
position OFF = Phantom 48V not active
When INPUT1 is active , the unit makes in Mute status all other signal sources