1.
IMPORTANT SAFETY INSTRUCTIONS
This guide provides installation and operation instructions for this pump. Consult your supplier
with any questions regarding this equipment.
1.1 When installing and using this electrical equipment, basic safety precautions
should always be followed:
•RISK OF ELECTRICAL SHOCK. Connect only to a branch circuit protected by a
ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify
that the circuit is protected by a GFCI.
•This pump is for use with permanent installed in ground or above ground swimming pools
and may also be used with hot tubs and spas if so marked. Do not use with above
ground pools that can be readily disassembled for storage.
• The pump is not submersible.
• Before servicing the pump; switch off power to the pump by disconnecting the main
circuit to the pump.
• Never open the inside of the drive motor enclosure.
1.2 All installations must be fitted with earth leakage or residual current protection
devices, having a rated residual operating current not exceeding 30mA.
WARNING
• Do not run the pump dry. In case of dry run, mechanical seal will be damaged and the pump will start
leaking. Fill the pump with water before starting.
• Before servicing the pump, switch OFF power to the pump by disconnecting the main circuit to the
pump and release all pressure from pump and piping system.
• Never tighten or loosen screws while the pump is operating.
• Do not block the pump suction.
2. TECHNICAL SPECIFICATIONS
Model
500VS11
500VS15
500VS22
kW
HP
kW
HP
kW
HP
Input Power
P1
1.1
1.5
1.5
2
2.2
3
Output Power
P2
0.75
1
1.1
1.5
1.7
2.3
Current
A
6.7
9.3
12.5
Qmax
m³/h
22.8
30
36
Hmax
m
16.5
20
22
Supply
V/Ph/Hz
220-240/1/50
Connections
mm
63
Motor Speed
RPM
1200-2900
Net Weight/Gross Weight
Kg
16.7/19.5
18.2/21
19.6/23