background image

      3301A  

 

 

使 用 手 冊 (E)

S/N: 90033013 rev:A

Содержание 3301A

Страница 1: ...3301A E S N 90033013 rev A...

Страница 2: ...me operation 9 3 1 Feet stands 9 3 2 Power switch 9 3 3 STORE RECALL operation 10 Chapter 4 GPIB programming operation 11 4 1 The summary of GPIB command 11 4 2 The description of abstraction 11 4 3 G...

Страница 3: ...ion 1 Table 4 1 GPIB Command listing 11 Table 4 2 GPIB command terminator 12 Table 4 3 Maximun load current level 16 Table 4 4 Slew rate code for SLOW MID and FAST 17 Table 4 5 specification code for...

Страница 4: ...ifferent specifications load module 2 Flexible configuration each slot of 3301A mainframe can be installed one of 3320 3321 or 3322 load module 3 STORE RECALL up to 5 states it can reduce the testing...

Страница 5: ...Y 5 SYSTEM CONTROLLER CPU RAM NON VOLATILE RAM I O etc POWER SUPPLY 1 ISOLATED I O INTERFACE 1 POWER SUPPLY 2 ISOLATED I O INTERFACE 2 ISOLATED I O INTERFACE 3 IEEE 488 INTERFACE MAINFRAME OPERATION K...

Страница 6: ...respond to your nominal line voltage Skip this procedure if the label is corrected marked 1 With the 3301A mainframe power OFF disconnect the power cord and remove two bottom cover screws 2 Turn the 3...

Страница 7: ...talled and is ready for used as a bench instrument The feet provide a good viewing angle for bench top use 2 5 Rack mount The 3301A mainframe is designed to permit mounted in a standard 19 inches rack...

Страница 8: ...ck screws are firmly hand tightened use a screwdriver only for the removal of screws Fig 2 3 shows the rear panel of 3301A mainframe the GPIB connector and GPIB address setting switch is located on th...

Страница 9: ...Address switch 2 10 Remote control Port The D sub 9 pin connector on the rear panel connects the 3301A mainframe to the PRODIGIT mode 9931 remote controller and to replace the RECALL option key 1 to 5...

Страница 10: ...ype cable to connect two 3301A mainframe Master and Slave unit 3 The channel number of Master Slave operating is shown in Fig 2 7 i e in the Master unit from left to right ch1 ch2 ch3 and ch4 and in S...

Страница 11: ...5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 CABLE DATA5 DATA6 DATA7 DATA8 CLK5 CLK6 CLK7 CLK8 CONTROL MASTER SLAVE STATIC LOAD D SUB 25P Con MASTER SLAVE STATIC LOAD D SUB 25P Con TO SE...

Страница 12: ...UT SENSE MONITOR V I F S 10V II RATE SLEW RANGE SHORT LOAD PRES STATE STORE 1 2 3 4 5 Figure 3 1 3301A front panel 3 1 Feet stands There are four feet which are located in each corner of the 3301A bot...

Страница 13: ...nnuciator will be blank it indicated the STORE process is not available now please repeat the STORE procedure for a new STORE operation 2 After press the STORE LED key then press the STORE key again t...

Страница 14: ...Excecute the commands which is waiting for trigger Table 4 1 GPIB Command listing 4 2 The description of abstraction 1 SP Space the ASCII code is 20 Hexadecimal 2 Semicolon Program line terminator th...

Страница 15: ...your GPIB programming statements In this manual the terminator is assumed at the end of each example line of code If it needs to be indicated it is shown by symbol nl which stand for new line and rep...

Страница 16: ...arranged as 1 2 3 4 from left hand side to the right hand side respectively or 1 2 3 4 for from the left hand side to the right hand side of the Master 3301A mainframe and 5 6 7 8 for from the left ha...

Страница 17: ...g load current level over the maximum specification of 3320 series load module the full scale current will be sent to the load module 5 The most effective load current level can be set is the fifth di...

Страница 18: ...ight hand corner of the 3301A mainframe is lit and the REM LED annuciator of each load module is lit also to indication remote programming operation MASTER OFF controls up to 4 channels of the Electro...

Страница 19: ...o the maximum of new range The maximum load current level is shows in table 4 3 Table 4 3 maximum full scale current level for each module When the programming load level setting is greater than the m...

Страница 20: ...oved Example a SHOR ON b SHOR OFF c SHOR TRIG ON SLEW Purpose SET the slew rate of load current change Command syntax SLEW SP 1 2 NL Description This command selects the load current slew rate SLOW MI...

Страница 21: ...to execute the GPIB command that are waiting for trigger Command syntax TRIG NL Description This TRIG command executes all of the operation simutaneously for all of the xxxx TRIG xxx GPIB command Exam...

Страница 22: ...one 3301A mainframe operation or channel 1 to channel 4 for Master unit of 3301A mainframe and channel 5 to channel 8 for slave unit of 3301A mainframe if the Master Slave D type cable is connected Th...

Страница 23: ...e same function like the STORE key on the 3301A mainframe but it has the following different features 1 The non volatile memory location of GPIB STORE and STORE key on the 3301A mainframe is seperated...

Страница 24: ...0 30 0 6 0 6 0 60 0 1 0 1 0 10 0 1 0 1 0 10 0 0 5 0 5 5 0 CHANNEL 2 CHANNEL 1 CHANNEL 3 CHANNEL 4 NO NO NO YES YES YES YES NO SET CHAN 1 SET CHAN 2 SET CHAN 3 SET CHAN 4 3325 1 5 1 5 15 0 SET RANG 1 S...

Страница 25: ...D SPEC C1 C2 C3 C4 C5 C6 C7 C8 CHAN N CLE LOAD TRIG SP ON OFF PPES TRIG SP ON OFF SHOR TRIG SP ON OFF CURR TRIG SP NR2 RANG SP 1 2 SLEW SP 1 2 3 MASTER SP ON OFF STORE SP 1 2 3 4 5 RECALL SP 1 2 3 4 5...

Отзывы: