Page 3
GUARANTEE
8 - GUARANTEE
Ü
The compressor is guaranteed for a period of
12 months starting from the date of purchase.
During this period, the manufacturer undertakes
to repair or to replace free of charge any
defective part, after an inspection has been
completed at the factory, in accordance solely
with the judgement of our technicians
.
Ü
The guarantee is restricted to manufacturing
defects and applies to equipment used under
normal conditions. The guarantee will not apply if
the machine has been dismantled or modified or
if there are missing parts.
It excludes any responsibility for direct or indirect
damage to persons, animals or objects: if there
are missing parts, if the material or subset were
dismounted or modified.
Ü
Parts which are subject to normal wear, e.g
pressure switches, piston rings, belts, air filters,
gaskets and valves, etc., do not fall within the
scope of the guarantee.
No return is accepted without prior authorization.
The carriage costs incurred in returning all
part of a machine, even under guarantee, will
always be charged to the user.
Ü
The respect of the advice of use will preserve
the performances, the life expectancy as well as the
legal guarantee applicable to your compressor.
Ü
A compressor not maintained can be damaged
quickly.
Ü
If you do not use the compressor in accordance
with the contents of these instructions, we will refuse
any responsibility towards persons animals or objects
damaged.
Ü
The compressor presented in this note was
designed in the respect of the safety requirements in
agreement with the directives and texts in force within
the European Community. (See EC Declaration).
Ü
This note was written in respect with Machine
Directive 2006/42/CE.
Ü
All uses advice necessary are indicated there.
Please keep this manual with the machine.
Please read entirely the safety requirements
and the instructions before using the
compressor.
To obtain the best results, respect all warnings
and instructions.
7 - GUARANTEE ADVICE
-For any communication with the distributor, please
indicate the identification sticker data of the product
-The sticker is applied on the side of the compressor.
IDENTIFICATION STICKER OF THE PRODUCT
Model reference
6 - COMMUNICATION- TRACKING PRODUCT
4 - MAINTENANCE
Abnormal noises, vibrations:
-Loosened or worned parts.
-Worn group (mechanical noises).
-Bad chocking of the compressor.
Low flow rate, pressure does not increase:
-Air filter is dirty, you must clean it.
-Air pressured is leaking by the connections, check the
connections.
-Cylinder valves are broken or valve seat gasket torn,
you must check the pump.
-Excessive consumption by the segmentation, gasket
leakages, you must check the pump.
Impossible adjustment of the output air pressure:
- The internal diaphragm of the pressure reducer is torn
(Ref: 41, Pict.2) replace it.
5 - FAULTS / SOLUTIONS
Ü
Avoid any degradation of the electric cable and
move away from heat sources higher than 70°C.
Ü
At the end of work, unplug the cable and roll up it
around the handle of the compressor.
Ü
Do not use the compressor with bare or wet feet.
Ü
Do not to touch the compressor with wet hands.
Ü
Do not pull the cord to move the compressor or
to remove the plug.
Ü
Do not allow children to use the compressor.
Ü
Do not leave the compressor without monitoring
when it is connected; it can become source of
dangers.
Ü
The electric safety of this machine is assured
only when it is correctly connected with an
efficient grounding connection , as recommended
in the rules of electric safety requirements
Ü
Your compressor is self lubricated (no oil).
Ü
Routine maintenance does not require
specialized personnel.
Ü
The maintenance of the pump and other more
complex organs, must be made by qualified
technician: Seek your dealer.
Specifications
The compressor don't stop or at another
pressure value:
- Defective valve of the pressure switch, change
it. (Contact a Reseller)
Pressure does not rise into the tank:
-No return valve blocked by an impurity or worn,
clean or change the no return valve or the internal
rubber valve with its spring. (Ref: 49, Pict.2)
The compressor does not start:
- No electrical supply.
-The compressor is already in pressure, empty the
tank.
The compressor starts with difficulty:
-The electric tension is insufficient. (210V Minimum).
-Electrical supply cord is too long, or wire section too
small. (electric cable coil)
-Engine overload by cold weather.
MAINTENANCE
FAULTS / SOLUTIONS
MARKING
Page 6
Pictograms key:
1 -Read carefully this manual before startup or any
maintenance operation.
2 -Use a sound protection in the event of prolonged
use.
3 -Risk of electric discharge.
4 -Disconnect electricity before undertaking
compressor maintenance.
5 -Do not open the air valve before you have
connected the air pipe and the tool to the
compressor.
6 -Do not breathe or project towards a person the
compressed air of the compressor.
7 -This equipment cannot be thrown as waste and is
subject to a selective collection for its valorization or
recycling.
1 2 3 4 5 6 7
Acoustic power level
guaranteed.
“CE” EUROPEAN COMPLIANCE
DECLARATION
PRODIF :
ZAC du pré clos - 500 rue Clément Ader - 78530 BUC
WE DECLARE AT OUR RESPONSABILITY THAT THE FOLLOWING PRODUCT :
MODEL :
SIL06J
COMPLIES WITH EUROPEAN GUIDELINES FOR SECURITY AND ENVIRONMENT ON THE
MACHINES:
2006/42/CE
- Machinery - Replaces the 98/37/CE
2006/95/CE
- LV - Low Voltage
2004/108/CE
- EMC - Electromagnetic compatibility
2009/105/CE
- Simple pressure vessels - Replaces the 87/404/CEE
2000/14/CE
- Noise emission by equipment used outdoors - Procedure: Annexe VI
Sound power level guaranteed : 59 dBA - Sound power level measured: 48 dBA
2002/96/CE
et
2002/95/CE
- WEEE et RoHS.
STANDARDS USED : EN 1012-1, EN ISO 12100-1 , EN ISO 12100-2, EN 13857, EN 286-1, EN953, EN ISO
13732-1,EN50419, EN 55014-1, EN61000-3-2, EN61000-3-3, EN 60204-1, ISO3857-1/-2.
BUC: The 2015-03-03
Le président: F . MURET