The pump must be connected to a 230 Volt power supply, slaved to pool filtration.
Check that earthing has been carried out in accordance with the standards in effect.
Ensure that the circuit is protected by a 30 mA differential circuit breaker.
Electrical data:
Voltage: 198 to 242 Vac - 50 Hz - Average consumption 5 Watts.
Never the connect the pump directly in parallel with any inductive loads (eg: motor).
P : Dosing pump
R : Relay
I : Double pole switch
E : Motor
A : Current
I - AVANT-PROPOS
PRIMING THE DOSING PUMP
All the series pH-/+220 dosing pump’s technical data is provided on the label affixed to the side
of the pump. This information includes the pump model, the power supply voltage, the flow rate
and the operating pressure. Dosing and pressure data indicated are valid for a water
temperature of 20°C.
WIRING AND PROTECTION
DOSING
The pH-/220 pump may be slaved to an external dry contact signal connected to the “
STAND-
BY
” BNC terminal under the pump (for example: pressure gauge, flow controller, etc.)
In this configuration, the pump will only run when the contact is active (contact closed)
.
SLAVING
Before commissioning the dosing pump, the material safety data and toxicology sheet of the
reagent used must be read carefully and all recommended safety precautions must be taken.
Once all the tubes have been connected, hold down the
ON/OFF
key. The pump will enter manual
mode and will start to run. Open the priming valve on the front of the pump body. When the liquid
arrives at the drainage tube, close the valve. release the key, the pump will stop.
This operation should, by preference, be carried out with water.