![Procon V3D Series Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/procon/v3d-series/v3d-series_programmers-manual_1608970038.webp)
H - I - J
PROGRAMMER’S MANUAL
V8.94.11-
- 38 -
Explanation of the program functions
program inhibit:
inhibits the running of the programs. It is in logic “AND” connection with menu item
9-10-1
.
program suspension:
the time limitation of the actually active program (
) becomes longer by the time of the
active state of the input.
program step:
stepping over from the running program to the next activated program, disregarded the time limit.
program 1 - 15:
activates the internal programs.
program binary activation:
activates the internal programs by binary code.
In case
of binary program start, so many inputs are to be selected to “binary” as it is required by the program of the
highest serial number to be activated:
•
at program 1:
1,
•
at program 2-3
2,
•
at program 4-7:
3,
•
at program 8-15:
4.
The digital inputs correspond to the increasing positional values of the binary codes according to their decreasing serial
numbers.
for example:
selected to “binary”: digital inputs 2, 3, 5
activation of program 6 (
110
): digital input 2:
1
, digital input 3:
1
, digital input 5:
0
sequence 1-3:
for activating program groups. (menu
Explanation of other functions
counter-3 F:
input for shifting the given counter upward.
counter -3 L:
input for shifting the given counter downward.
counter -3 B:
input for writing the given counter. (in case of zero starting value zero setting input)
i
The counters can be programmed independently (direction, zero setting). They can be used for stopping
and display.
memory 1-3:
pulse loading command. Activating this input effects loading of the parameter set, if the equipment
does not work, or during stop with spin out.
i
At these settings the naming of the parameter set does not appear, unlike in menu item
. (Parameter
loading from memory)
Independently from the naming, the selectable memories are always memory 1, memory 2 or memory 3!
knife up:
in case of flying scissor the “knife up” sensor has to be connected to this input.
Virtual inputs
The virtual inputs permit to achieve the same effects as the digital inputs on the terminal block. However here the source
of the input (
) is an internal discrete signal (comparator output signal or time interval) or remote control. Thus,
even more complicated tasks can be fulfilled without the use of any further device
Содержание V3D Series
Страница 1: ...H I J frequency converters programmer s manual from software version V8 94 11 onwards P Since 1984...
Страница 2: ......
Страница 85: ...H I J PROGRAMMER S MANUAL V8 94 11 85 User settings Submenu Explanation Setting Unit...
Страница 86: ...H I J PROGRAMMER S MANUAL V8 94 11 86 Notes...
Страница 87: ......