15. Do not use appliance if any part

has been exposed to or under water.
Immediately call a qualified service
technician to inspect the room
appliance and to replace any part of
the control system (if using control
system) and any gas control which
has been under water. 

16. To help prevent breakage, new logs

must be broken-in (see Curing Logs
page 6). 

17. Turn log set off and let cool before

servicing, installing, or repairing.
Only a qualified service person
should install, service, or repair log
set.

 

 

 

SAFETY 
INFORMATION

 

3.    Never install the log set 

  in a recreational vehicle 

where curtains, furniture, clothing, 
or other flammable objects are 
less than 42 inches from the front, 
top, or sides of the log set 

  in high traffic areas 

  in windy or drafty areas 

4.  Before installing in a solid fuel 

burning fireplace, the chimney flue and 
fire-box must be cleaned of soot, 
creosote, ashes and loose paint by a 
qualified chimney cleaner. Creosote 
will ignite if highly heated. Inspect 
chimney flue for damage. 

5. You must operate this log set with a 

fire-place screen in place. Make sure 
fireplace screen is closed before 
running log set. If the fireplace has 
glass doors, they must remain OPEN 
while this log set is in operation.   

6. This log set is designed to be smoke- 

less. If logs ever appear to smoke, turn 
off appliance and call a qualified 
service person. Note: During initial 
operation, slight smoking could occur 
due to log curing and the burning of 
manufacturing residues. You may wish 
to add more ventilation by opening a 
window. 

7. To reduce the creation of soot, follow 

the instructions in the Cleaning and 
Maintenance section, page 6. 

8. Do not allow fans to blow directly into 

the fireplace. Avoid any drafts that alter 
burner flame patterns. Ceiling fans can 
create drafts that alter burner flame 
patterns. Altered burner patterns can 
increase sooting. 

9.Do not use a blower insert, heat 

exchanger insert, or other accessory 
not approved for use with this log set. 

10.This log set needs fresh, outside air 

ventilation to run properly. See the Air 
for Combustion and Ventilation section, 
page 3. 

11. Do not run log set 

 where flammable liquids or 

vapors are used or stored 

  under dusty conditions 

12. Do not burn solid fuel in the fireplace 

after installing the log set. Do not use 
this log set to cook food or burn paper 
or other objects. 

13. Log set becomes very hot when in 

use. Keep children and adults away 
from hot surface to avoid burns or 
clothing ignition. Log set will remain hot 
for a short time after shut-down. Allow 
surface to cool before touching. 

14. Carefully supervise young children 

when they are in the room with log set. 

 

WARNING: Keep flue open 

when operating unit. 

IMPORTANT: Read this owner's 
manual carefully and completely 
before trying to assemble, 
operate, or service this log set. 
Improper use of this log set can 
cause serious injury or death 
from burns, fire, explosion, 
electrical shock, and carbon 
monoxide poisoning. 

1.This appliance, as supplied, is only for 

use with the type of gas indicated on 
the rating plate. This appliance is 
convertible for use with propane/LP, 
using the MANUAL ON/OFF VALVE/ 
SAFETY PILOT KIT. 

2. If you smell gas 

  shut off gas supply 

  do not try to light any appliance 

do not touch any electrical switches; 
do not use any phone in your building 

immediately call your gas supplier 

from a neighbor's phone. Follow the 
gas supplier's instructions 

  if you cannot reach your gas supplier, 
call the fire department

 

Carbon Monoxide Poisoning:

 Early 

signs of carbon monoxide poisoning 
resemble the flu with headaches, 
dizziness, or nausea. If you have these 
signs, the log set may not be working 
properly. 

Get fresh air at once!

 Have 

log set serviced. Some people are 
more affected by carbon monoxide 
than others. These include pregnant 
women, people with heart or lung 
disease or anemia, those under the 
influence of alcohol, and those at high 
altitudes. 

 

Natural Gas:

 Natural gas is odorless. 

An odor-making agent is added to the 
gas. The odor helps you detect a gas 
leak. However, the odor added to the 
gas can fade. Gas may be present 
even though no odor exists. 

 

Make certain you read and understand 
all warnings. Keep this manual for 
reference. It is your guide to safe and 
proper operation of this log set. 

WARNING: Any change to this 

log set or its controls can be 
dangerous. 

1. Remove logs, hearth kit, pan materials, 

and hardware from carton. 

2. Remove all protective packaging applied 

to logs and base for shipment. 

3. Check all items for any shipping damage. 

If damaged, promptly inform dealer 
where you bought the product. 

 CAUTION:

 

Do not remove the 

metal data plates from the burner pan. 
The data plates contain important 
product information. 

UNPACKING 

LOCAL CODES 

Install and use log set with care. Follow all 
local codes. In the absence of local codes, 
use the latest edition of The National Fuel 
Gas Code ANS Z223.1, also known as 
NFPA 54*. 

*Available from: 

American National Standards Institute, Inc. 

1430 Broadway 

New York, NY 10018 

National Fire Protection Association, Inc. 

Batterymarch Park 

Quincy.MA 02269

 

DANGER: Carbon monoxide 

poisoning may lead to death! 

OPTIONAL PRODUCT   
FEATURES 

 

ON/OFF VALV/SAFETY PILOT KIT
AND PROPANE/LP CONVERSION

An optional on/off valve/safety pilot kit with
a piezo ignitor is available for this
appliance. This system requires no
matches, batteries, or other sources to
light. You must use this optional system
for LP conversion.  See accessories,
page 6. 

Содержание WAN18LA

Страница 1: ...on may result causing property damage personal injury or loss of life WARNING This is a gas fired appliance It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on page 3 of this manual Aftermarket Completion of sale not for purpose of resale from the manufacturer Do not...

Страница 2: ...oung children when they are in the room with log set WARNING Keep flue open when operating unit IMPORTANT Read this owner s manual carefully and completely before trying to assemble operate or service this log set Improper use of this log set can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning 1 This appliance as supplied is only for use with ...

Страница 3: ...st provide adequate fresh air for these appliances This will insure proper venting of vented fuel burning appliances NOTICE Installation service and repair of this appliance must be performed by a qualified installer service agency company or gas supplier experienced with this type of gas appliance Only factory authorized components listed in these instructions may be used in accordance with the m...

Страница 4: ...ed or the damper blade must be cut or removed CAUTION Only use a new black iron or steel pipe Internally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to log set If pipe is too small loss of pressure will occur Installation must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap w...

Страница 5: ...e gas valve immediately Tighten or reassemble the loose connection s using pipe joint compound until burner system is leak free 4 When the burner is tested and leak free observe the individual tongues of flame on the burner Note The burner design includes more ports on the outside of the bar Make sure that all ports are clear and producing flame evenly across the burner If any ports appear blocked...

Страница 6: ... burning turn the shutoff valve OFF and repeat steps 1 through 4 again CURING LOGS During the 2 3 hour appliance break in period you may detect an odor from the appliance as the various paints and compounds used in the manufacturing of this log set cure This is a normal and temporary situation that is not cause for alarm However you may want to provide extra ventilation to the room during this tim...

Страница 7: ...and checked 3 Separate the logs to allow more flame passage 4 Remove any foreign items from the flame pattern 5 Preheat flue in very cold weather POSSIBLE CAUSE OBSERVED PROBLEM Log set is smoking sooting excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs 1 Relieve any tight bends or kinks in gas supply lin...

Страница 8: ...PRO COM OWNER S MANUAL VENTED GAS LOGS 8 WAL21 01 ILLUSTRATED PARTS BREAKDOWN WAN18LA WAN24LA WAN30LA ...

Страница 9: ... Adapter 1 4 WAL06 01 WAL06 01 WAL06 01 Injector Mounting 1 5 ML091 04 WAL07 02 WAL07 03 Injector 1 6 WAL01 01 WAL01 02 WAL01 03 Burner Pan 1 7 WAL02 01 WAL02 02 WAL02 03 Burner Manifold 1 8 WAB01 WAB05 WAB07 Logs Grate 1 9 WAL18 01 WAL18 01 WAL18 01 Grate Step 2 10 WAB03 WAB03 WAB03 Damper Clamp Assembly 1 11 6170 4Z 6170 4Z 6170 4Z Nut 1 12 861 1 4Z 861 1 4Z 861 1 4Z Washer 1 13 WAL19 01 WAL19 0...

Страница 10: ... 2 Place the back log 1 onto the grate steps see Figure 3 3 Place the front logs 2 3 on the grate and slide forward against the front bars on the grate see Figure 4 4 Place logs 4 5 onto logs 1 2 3 by inserting log 1 s locating pin into lower hole of logs 4 5 see Figure 5 5 Place log 6 onto log 5 by inserting log 5 s locating pin into lower hole of log 6 see Figure 6 6 Place log 7 onto logs 4 6 by...

Страница 11: ...PRO COM OWNER S MANUAL VENTED GAS LOGS 11 WAL21 01 WAN18LA LOG INSTALLATION Continued Figure 6 Placement of Top Logs Figure 5 Placement of Top Logs Figure 7 Placement of Top Logs ...

Страница 12: ...igure 3 3 Place the front logs 2 3 on the grate and slide forward against the front bars on the grate see Figure 4 4 Place logs 4 5 onto logs 1 2 3 by inserting log 1 s locating pin into lower hole of logs 4 5 see Figure 5 5 Place log 6 onto log 5 by inserting log 5 s locating pin into lower hole of log 6 see Figure 6 6 Place log 7 onto logs 4 6 by inserting log 4 s locating pin into lower hole of...

Страница 13: ...COM OWNER S MANUAL VENTED GAS LOGS 13 WAL21 01 Figure 6 Placement of Top Logs WAN24LA LOG INSTALLATION Continued Figure 8 Placement of Top Logs Figure 7 Placement of Top Logs Figure 5 Placement of Top Logs ...

Страница 14: ...e 3 3 Place the front logs 2 3 on the grate and slide forward against the front bars on the grate see Figure 4 4 Place logs 4 5 6 onto logs 1 2 3 by inserting log 1 s locating pin into lower hole of logs 4 5 6 see Figure 5 5 Place log 7 onto logs 4 5 by inserting log 4 s locating pin into lower hole of log 7 see Figure 6 6 Place log 8 onto logs 2 4 by inserting log 4 s locating pin into lower hole...

Страница 15: ...PRO COM OWNER S MANUAL VENTED GAS LOGS 15 WAL21 01 WAN30LA LOG INSTALLATION Continued Figure 6 Placement of Top Logs Figure 7 Placement of Top Logs Figure 5 Placement of Top Logs ...

Страница 16: ...re not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF TH...