CONNECTING  TO  GAS SUPPLY

          WARNING:  A  qualified  service
person  must  connect  heater  to  gas
supply. Follow  all  local  codes.

         CAUTION:    Never      connect heater
directly  to  the  gas supply.  This  heater
requires an    external  regulator (not
supplied). lnstall  the  external  regulator
between the  heater  and gas supply.

INSTALLATION   ITEMS  NEEDED
Before  installing  heater, make  sure you
have  the  items  listed  below.

 

piping (check  local  codes)

   sealant (resistant to natural or propane/

      LP gas)

   equipment  shutoff  valve*

   test  gauge  connection*

   sediment  trap

   see  joint

   pipe  wrench

   flexible gas  hose (check local codes)

* A  CSA  design-certified  equipment shutoff
valve   with 1/8

 NPT  tap  is  an acceptable

alternative  to  test   gauge  connection.
Purchase  the    optional  CSA  design-cer-
tified         equipment  shutoff  valve and flex
hose from your dealer. See  Accessories,
page 14.

Figure  7 -Gas  Connection

The  installer  must  supply  an  external
regulator.  The  external  regulator  will re-
duce  incoming  gas  pressure. You must
reduce  incoming  gas  pressure to  between
11 to 14

 

 inches. If you do not reduce in-

coming gas pressure, heater regulator dam-
age could  occur. lnstall external regulator
with  the  vent  pointing  down  as  shown in
Figure  6.  Pointing  the  vent  down protects
it  from  freezing  rain  or  sleet.

*   Purchase  the  optional  CSA  design-certified  equipment  shutoff  valve and flex hose from

    your  dealer. See  Accessories, page  14.

** 11” W.C. pressure is the minimum  inlet  pressure  for  purpose  of  input  adjustment.

INSTALLATION

Continued

          WARNING:  Never connect heater
to private (non-utility) gas wells. This gas
is commonly known as wellhead gas.

         CAUTION:   Only use a new  black
iron  or  steel  pipe. Internally-tinned cop-
per  tubing  may  be  used  in certain  areas.
Check  your  local  codes.  Use  pipe  of 1/

2

"

 diameter  or greater  to  allow  proper

gas  volume to  heater. If  pipe  is  too
small, undue loss  of  pressure  will  occur.

Installation  must   include  an   equipment
shutoff  valve, union, and plugged 1/8

"

 NPT

tap.  Locate  NPT  tap  within  reach  for  test
gauge  hook up.  NPT  tap  must  be  up-
stream  from heater (see  Figure 7).

IMPORTANT:  Install     equipment shutoff
valve  in  an  accessible  location.  The  equip-
ment  shutoff   valve  is  for  turning  on  or
shutting  off  the  gas  to  the  appliance.
Apply pipe  joint  sealant  lightly  to  male
threads.This  will  prevent  excess      seal-
ant  from going into pipe. Excess   sealant
in  pipe  could  result  in clogged heater
valves.

         CAUTION:   Use pipe joint sealant
that  is  resistant  to  liquid petroleum(LP)
gas.

We  recommend  that  you install  a sedi-
ment  trap  in  supply  line  as  shown in
Figure 7. Locate  sediment  trap  where  it  is
within  reach  for  cleaning. Install  in  piping
system  between  fuel supply  and  heater.
Locate  sediment trap  where  trapped  mat-
ter is not  likely to  freeze.  A  sediment  trap
traps  moisture  and  contaminants. This
keeps  them  from  going  into  heater
controls. If  sediment  trap  is  not      in-
stalled  or  is  installed  incorrectly,  heater
may  not  run  properly.

               CAUTION:   Avoid  damage to
regulator. Hold  gas  regulator  with wrench
when  connecting  into  gas piping  and/or
fittings.

NG MODELS:
5” to 10.5” W.C.
Gas supplier provides  external regula-
tor for natural gas.

Figure 6- External Regulator
With Vent Pointing Down

Figure 5-Gas Regulator Location and
Gas Line Access Into Heater Cabinet

Front View

Side View

Gas Regulator
Inlet Connection

Front
of
heater
unit

’’

Содержание SL250TYLA-D

Страница 1: ...ENTED ROOM HEATERS Water vaporis a by product of gas combustion An unvented room heater productes approximately one 1 ounce 30ml of water for every 1 000 BTU s 3KW s of gas input per hour Refer to pag...

Страница 2: ...e Propane LP supply tank s indoors 3 If you smell gas Shut off gas supply Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call yo...

Страница 3: ...ee operation State and local codes in some areas prohibit the use of vent free heaters UNPACKING 1 Remove top inner pack 2 Tilt carton so that fireplace is upright 3 Remove protective side packaging 4...

Страница 4: ...ing if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining ro...

Страница 5: ...oom unconfined Figure 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr WARNING If the area in which the heater may be op...

Страница 6: ...late If your gas supply can not meet that requirement do not install heater Call dealer where you bought heater from for proper heater type Figure 4 Minimum Clearance to Wall CLEARANCES TO COMBUSTIBLE...

Страница 7: ...gas is commonly known as wellhead gas CAUTION Only use a new black iron or steel pipe Internally tinned cop per tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or g...

Страница 8: ...ure of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks...

Страница 9: ...chnician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the safety informatuion above 2 Set the...

Страница 10: ...55 F 12 78 C If no heat is desired turn the gas cntrol knob to the PILOT position Main Burner Operation Description of Gas Control Knob OFF position PILOT position LO HI will allow the hydraulic ther...

Страница 11: ...pas sageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a qualified service person Heater may need more frequent cleaning due to excessive lint from...

Страница 12: ...Pilot flame not touching thermocouple This allows thermocouple to cool causing the pilot flame to go out This problem could be caused by one or both of the following A Low gas pressure B Dirty or part...

Страница 13: ...n logs or inside of fireplace 1 Improper log placement 2 Air holes at burner inlet are blocked 3 Burner flame holes are blocked 1 Properly locate logs see Installing Logs page 9 2 Clean out air holes...

Страница 14: ...o return the defective part to the factory Warranty card PARTS NOT UNDER WARRANTY Contact authorized dealers of this prod uct or Parts Central If they can t supply original replacement part s call PRO...

Страница 15: ...ngle iron Figure 3 Insert the pinhole on the upper part of log 4 into the pin on the left side of log 1 Place the lower part on the flat roof at the left side of log 3 Figure 4 Insert the pinhole on t...

Страница 16: ...16 ILLUSTRATED PARTS BREAKDOWN SN250TYLA D SL250TYLA D...

Страница 17: ...0 4 2 0 L E G N r o t c e j n I 1 8 0 1 0 5 2 0 L E P L r o t c e j n I 1 9 0 0 0 0 7 3 B E y l b m e s s A e b u T t e l t u O 1 1 0 1 3 1 F 1 8 V R N G N 3 I F 1 8 V R r o t a l u g e R 1 1 1 8 1 F...

Страница 18: ...18 ILLUSTRATED PARTS BREAKDOWN SN250TYLA D SL250TYLA D 20...

Страница 19: ...1 0 0 L S n m u l o C t h g i R 1 1 8 1 0 1 1 0 L E e r i W g n i t a r o c e D r e p p U 1 1 9 4 0 3 0 2 0 0 L S r e v u o L d i M r e p p U 2 2 0 1 6 0 6 0 0 L E r o t c e l f e R e d i S 2 2 1 1 1...

Страница 20: ...thread that previously bond the electrical wire to collect and pack the outside connection wire of the cable 6 Place operation control housing at the bottom of stove Use two black screws provided in b...

Страница 21: ...21 INSTALLING BLOWER ACCESSORY BLOWER ACCESSORY MODEL NFHTX186 Figure 4 A Routing Power Cord Figure 4 B Routing Power Cord Wiring Diagram Decal Figure 5 Mounting Control Housing SIDE VIEW...

Отзывы: