Problem

Possible Cause

Corrective Action

ODS/pilot lights but flame 

goes  out  when  control 

knob is released.

1. Control  knob  is  not  fully 

pressed in.

2. Control knob is not pressed 

in long enough.

3. Equipment  shutoff  valve  is 

not fully open.

4. Thermocouple connection is 

loose at control valve.

5. Pilot  flame  not  touching 

thermocouple, which allows 

thermocouple to cool, caus-

ing pilot flame to go out. This 

problem could be caused by 

one or both of the following:

  A) Low gas pressure

  B) Dirty or partially clogged 

ODS/pilot

6. Thermocouple damaged.

7. Control valve damaged.

1. Press in control knob fully.

2. After ODS/pilot lights, keep 

control  knob  pressed  in  30 

seconds.

3. Fully open equipment shutoff 

valve.

4. Hand tighten until snug, and 

then tighten 1/4 turn more.

5. A)  Contact  local  natural  or 

propane/LP gas company

  B)  Clean  ODS/pilot  (see 

Care and Maintenance

, page 

22) or replace ODS/pilot as-

sembly 

6. Replace thermocouple.

7. Replace control valve.

Burner(s) does not light 

after ODS/pilot is lit.

1. Burner orifice is clogged.

2. Burner orifice diameter is too 

small.

3. Inlet gas pressure is too low.

1. Clean  burner  orifice  (see 

Care and Maintenance

, page 

22) or replace burner orifice.

2. Replace burner orifice.

3. Contact local gas supplier.

Delayed  ignition  of 

burner(s).

1. Manifold pressure is too low.

2. Burner orifice is clogged.

1. Contact local gas supplier.

2. Clean burner (see 

Care and 

Maintenance

,  page  22)  or 

replace burner orifice.

Burner backfiring during 

combustion

1. Burner orifice is clogged or 

damaged.

2. Burner is damaged.

3. Gas regulator is damaged.

1. Clean  burner  orifice  (see 

Care and Maintenance

, page 

22) or replace burner orifice.

2. Contact customer service.

3. Replace gas regulator.

High yellow flame during 

burner combustion

1. Not enough air.

2. Gas regulator is defective.

3. Inlet gas pressure is too low.

1. 

Check burner for dirt and debris. 

If found, clean burner (see 

Care 

and Maintenance

, page 22).

2. Replace gas regulator.

3. Contact local gas supplier.

Gas  odor  during  com-

bustion.

1. Foreign  matter  between 

control valve and burner.

2. Gas  leak.  (See  Warning 

Statement at top of page 23).

1. Take  apart  gas  tubing  and 

remove foreign matter.

2. Locate and correct all leaks 

(see 

Checking Gas Connec-

tions

, page 16).

Slight smoke or odor dur-

ing initial operation.

1. Residues from manufactur-

ing process.

1. Problem will stop after a few 

hours of operation.

TROUBLESHOOTING

Содержание MGT10BF

Страница 1: ...cal switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire d...

Страница 2: ...s manual WARNING Improper installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For a...

Страница 3: ...re more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and those at high altitudes NATURALAND P...

Страница 4: ...s may create a white powder residue within burner box or on adjacent walls or furniture 8 Do not use heater if any part has been under water Immediately call a qualified service technician to inspect...

Страница 5: ...Heater Weight 16 5 lbs 22 lbs Shipping Weight 19 4 lbs 26 7 lbs Model MGT30BF Ignition Piezo Ignitor Gas Type Natural Gas Propane Gas BTU Hr Input Max available 30 000 30 000 BTU Hr Input Min availab...

Страница 6: ...ew York NY 10018 National Fire Protection Association Inc 1 Batterymarch Park Quincy MA 02269 9101 This heater is designed for vent free op eration State and local codes in some areas prohibit the use...

Страница 7: ...e combustion and ventilation air Read the following instructionstoinsureproperfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever...

Страница 8: ...nto adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation Air From...

Страница 9: ...igure 4 Mounting Clearances as Viewed From Front of Heater IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may...

Страница 10: ...ped there for shipping Remove mounting bracket from back panel Methods For Attaching Mounting Bracket To Wall Use only the last hole on each end of mount ing bracket to attach bracket to wall Attach m...

Страница 11: ...bracket is firmly fastened to wall studs Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry 1 Drill holes at mar...

Страница 12: ...talling Bottom Mounting Screws Installing Wall Spacers 1 Place heater on wall mounting bracket 2 Mark screw locations on wall 3 Remove heater from mounting bracket 4 If installing bottom mounting scre...

Страница 13: ...of regulator a qualified installer or service technician must use supplied cap You will notice a color coded plungerontheinsideoftheregu lator Thisisnormal Whenthein let connection fitting is inserted...

Страница 14: ...the connection fitting While pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to complete tight...

Страница 15: ...ator between the heater and gassupply Gassupplierprovides externalregulatorfornaturalgas Theinstallerprovidestheexternal regulator for propane LP gas CAUTION Avoid damage to regulator Hold gas regulat...

Страница 16: ...ulator with Vent Pointing Down Propane LP Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge Connection Sedimen...

Страница 17: ...ONS 5 Correct all leaks at once 6 Light heater see Lighting Instructions on page 18 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 19 1 Open equipment...

Страница 18: ...2 Make sure equipment shutoff valve is fully open 3 Turn control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out any air Then smell for gas including near the floor If you smell...

Страница 19: ...old match to pilot until pilot lights 7 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob If control knob does not pop up when released contact a...

Страница 20: ...lectrical Outlet ELECTRICAL WIRING Any electrical re wiring of this appliance must be done by a qualified electrician This wiring must be done in accordance with local codes and or in Canada with the...

Страница 21: ...which shuts the heater off If pilot flame pattern is incorrect as shown in Figure 25 turn heater off see To Turn Off Gas to Ap pliance page 19 see Troubleshooting pages 23 through 26 WARNING If yellow...

Страница 22: ...minutes 2 Remove four screws securing front panel 3 Pull front panel forward 4 Inspect burner and pilot for dust and dirt 5 Blow air through the ports slots and holes in the burner 6 Replace front pan...

Страница 23: ...as well as the fan heater is recommended For heavy or continuous use periodic cleaning must be done more frequently If the heater blows alternating cold and warm air check the fan for free movement an...

Страница 24: ...is clogged 5 Incorrectinletgaspressureorin let regulator setting is damaged 6 Control knob not in PILOT position 7 Depleted gas supply pro pane 1 Turn on gas supply or open equipment shutoff valve 2...

Страница 25: ...Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 22 or replace burner orifice 2 Replace burner orifice 3 Contact local gas supplier Delayed ignition of burner s 1 Ma...

Страница 26: ...carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products Heater produces un wanted odors 1 Heater is burning vapors from...

Страница 27: ...our model and serial numbers of your heater ready REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARR...

Страница 28: ...www usaprocom com 200272 01A 28 PARTS MODEL MGT10BF 2 10 3 1 8 7 5 6 9 13 12 11 4...

Страница 29: ...02 Mounting Bracket 1 3 ML083 04 Piezo Ignitor 1 4 STL1001 Thermostat Valve Assembly 1 5 Burner Assembly 1 6 ND0310A MU 600 PI4 ODS Pilot 1 7 RVD88 UB 4 9 Safety Dual Fuel Regulator 1 8 160960 01 Cap...

Страница 30: ...www usaprocom com 200272 01A 30 PARTS MODELS MGT20BF AND MGT30BF 10 2 11 3 1 8 7 5 6 9 14 13 12 15 16 4...

Страница 31: ...ly 1 5 Burner Assembly 1 6 ND0310A MU 800 PI6 ND0310A MU 800 PI6 ODS Pilot 1 7 RVD88 MAB 4 9 RVD88 MAB 4 9 Safety Dual Fuel Regulator 1 8 160960 01 160960 01 Cap with Seal 1 9 160960 02 160960 02 Inle...

Страница 32: ...will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORTANT The heater MUST be installed by a qualified installer in accordance wit...