NOTICE: This heater is intended 

for  use  as  supplemental  heat. 

Use this heater along with your 

primary heating system. Do not 

install  this  heater  as  your  pri-

mary heat source. If you have a 

central heating system, you may 

run system’s circulating blower 

while using heater. This will help 

circulate the heat throughout the 

house. In the event of a power 

outage, you can use this heater 

as your primary heat source.

 WARNING: A  qualified ser-

vice person must install heater. 

Follow all local codes.

 WARNING: Before installing 

in a solid fuel burning fireplace, 

the  chimney  flue  and  firebox 

must be cleaned of soot, creo-

sote, ashes and loose paint by 

a  qualified  chimney  cleaner. 

Creosote  will  ignite  if  highly 

heated. A dirty chimney flue may 

create and distribute soot within 

the house. Inspect chimney flue 

and firebox for damage. If dam-

aged, repair flue before operat-

ing heater.

 WARNING: Seal any fresh 

air vents or ash clean-out doors 

located on floor or wall of fire-

place. If not, drafting may cause 

pilot  outage  or  sooting.  Use  a 

heat-resistant  sealant.  Do  not 

seal chimney flue damper.

 WARNING: Never install the 

heater

•  in a bedroom or bathroom

•  in a recreational vehicle

• where curtains, furniture, 

clothing,  or  other  flammable 

objects are less than 42" from 

the front, top, or sides of the 

heater.

•  in high traffic areas

•  in windy or drafty areas

  CAUTION:  This  heater  cre-

ates  warm  air  currents.  These 

currents move heat to wall sur-

faces next to heater. Installing 

heater next to vinyl or cloth wall 

coverings  or  operating  heater 

where  impurities  (such  as  to-

bacco smoke, aromatic candles, 

cleaning fluids, oil or kerosene 

lamps, etc.) in the air exist, may 

discolor walls or cause odors.

IMPORTANT:

  Vent-free  heaters  add  mois-

ture  to  the  air. Although  this  is  beneficial, 

installing  heater  in  rooms  without  enough 

ventilation air may cause mildew to form too 

much moisture. See 

Air for Combustion and 

Ventilation

, page 7.

CHECK GAS TYPE

Be sure your gas supply is right for your heat-

er. Otherwise, call dealer where you bought 

the heater for proper type heater.

Содержание FBNSD400T-ZC Series

Страница 1: ...mmediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be perform...

Страница 2: ...of this manual WARNING Improper installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures...

Страница 3: ...low fans to blow directly into the heater Avoidanydraftsthatalterburner flame pattern including ceiling fans Altered burner patterns can cause sooting SAFETY WARNING Do not attempt to access or change...

Страница 4: ...oducts may create a white powder residue within burner box or on adjacent walls or furniture 8 Always run heater with control knob at PILOT IGN or ON 1 thru 5 positions never set control knob between...

Страница 5: ...h air PIEZO IGNITION SYSTEM This heater is equipped with an electronic piezo control system This system requires AAA batteries provided THERMOSTAT HEAT CONTROL The control automatically cycles the bur...

Страница 6: ...alth of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachuset...

Страница 7: ...erfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction methods help reduce...

Страница 8: ...nto adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation Air From...

Страница 9: ...or ash clean out doors located on floor or wall of fire place If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper WARNING Never install the h...

Страница 10: ...ill be pushed back by the fitting making all of the adjustments for the gas being supplied DO NOT REMOVE THE PLUNGER The regulator will not work and the warranty will be voided Theinletregulatoriscolo...

Страница 11: ...eshelf3 8 NPTpipe cap This will damage the plung ers located inside the regulator DO NOT TRY TO REMOVE THE PLUNGERS FROM INSIDE THE REGULATOR THE PLUNGER WILLBEPUSHEDBACKASTHE FITTINGISINSTALLED REMOV...

Страница 12: ...should not be less than 12 see Figure5 B Clearance from the top of the fireplace to the ceiling must not be less than 48 BUILT IN FIREPLACE INSTALLATION WARNING Do not allow any combustiblematerialsto...

Страница 13: ...standoff brackets in the hardware bag Remove screws from the top of the firebox Install brackets with screws as shown in Figure 10 3 Carefully set fireplace in front of rough opening with back of fir...

Страница 14: ...p is an acceptable al ternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice technician must connect heater...

Страница 15: ...f you do not reduce incom Figure 12 External Regulator with Vent Pointing Down External Regulator with Vent Pointing Down Propane Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Ni...

Страница 16: ...Ifbubblesform there isaleak Correctallleaksatonce PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect heater with its appliance main gas valve control v...

Страница 17: ...s very important to install the logs exactly as instructed Do not modify logs Use only logs supplied with heater Each log is marked with a number This number will help you to identify the logs when in...

Страница 18: ...ct For long periods of non operation remove batteries from all components for safety Unscrew ignitor cap and install a AAA battery with the pointing out Replace cap Figure 20 Installing Battery in Ign...

Страница 19: ...n under water FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS WARNING You must oper ate this heater with the screen in place Make sure screen is installed before running heater NOTICE Durin...

Страница 20: ...starting again 10 Make sure heater screen is in place before operating heater 11 If heater will not operate follow the in structions To Turn Off Gas To Appliance and call your service technical or ga...

Страница 21: ...ping follow instructions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the heater and burn causing brief patches of orange flame App...

Страница 22: ...irt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner Rep...

Страница 23: ...air through the air inlet hole You may blow through a drinking straw if compressed air is not available CABINET ODS PILOT Air Passageways Use a vacuum cleaner or pressurized air to clean Exterior Use...

Страница 24: ...pressure switch See instructions below The entire gas delivery piping including con nections inside the heater should be leak tested by the qualified installer After leak testing the qualified instal...

Страница 25: ...rn control knob to PILOT position 3 Fully press in control knob while pressing ignitor button 4 Continue holding down control knob Repeat igniting operation until air is removed 5 Clean ODS pilot see...

Страница 26: ...oo low 3 Gas regulator is defective 1 Check burner for dirt and debris If found clean burner see Care and Maintenance page 22 2 Contact local gas supplier 3 Replace gas train Slight smoke or odor duri...

Страница 27: ...noise is exces sive contact qualified ser vice technician White powder residue forming within burner box or on adjacent walls or furniture 1 When heated the vapors from furniture polish wax carpet cle...

Страница 28: ...www usaprocom com 200348 01C 28 PARTS MODEL FBNSD400T ZC 7 8 1 5 2 3 6...

Страница 29: ...page 30 of this manual ITEM PART DESCRIPTION QTY 1 161818 01HT Hood 1 2 161368 01HT Left Door Assembly 1 3 161369 01HT Right Door Assembly 1 5 161822 01 Gas Train Assembly 1 6 161338 01 Ignitor 1 7 1...

Страница 30: ...c at 1 866 573 0674 for information EQUIPMENT SHUTOFF VALVE For all models Equipment shutoff valve with 1 2 NPT tap Model and serial number of your heater How heater was malfunctioning Type of gas use...

Страница 31: ...ified heat propane gas supply might be low propane units only You may feel your gas pressure is too low If so contact your local gas supplier TECHNICAL SERVICE You may have further questions about ins...

Страница 32: ...rt s MUST be obtained through ProCom Heating Inc who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORTANT The heater MUST be...

Отзывы: