Procom FBNSD400T-ZC Series Скачать руководство пользователя страница 3

www.usaprocom.com

3

200348-01C

 DANGER: Carbon monoxide 

poisoning may lead to death!

Carbon Monoxide Poisoning:

 Early signs 

of carbon monoxide poisoning resemble the 

flu, with headaches, dizziness or nausea. If 

you  have  these  signs,  the  heater  may  not 

be  working  properly.  Get  fresh  air  at  once! 

Have  heater  serviced.  Some  people  are 

more affected by carbon monoxide than oth-

ers. These include pregnant women, people 

with heart or lung disease or anemia, those 

under the influence of alcohol and those at 

high altitudes.

Natural  and  Propane  Gas: 

Natural  and 

Propane gas are odorless. An odor-making 

agent is added to the gas. The odor helps you 

detect a gas leak. However, the odor added to 

the gas can fade. Gas may be present even 

though no odor exists.

 WARNING: FIRE, EXPLOSION 

AND ASPHYXIATION HAZARD
Improper adjustment, alteration, 

service,  maintenance,  or 

installation of this heater or its 

controls can cause death or 

serious injury.
Read and follow instructions 

and  precautions  in  User's 

Information  Manual  provided 

with this heater.

 WARNING: Do not use a 

blower  insert,  heat  exchange 

insert or other accessory not 

approved  for  use  with  this 

heater.

 WARNING: Do not allow fans 

to blow directly into the heater. 

Avoid any drafts that alter burner 

flame pattern including ceiling 

fans.  Altered  burner  patterns 

can cause sooting.

SAFETY

 WARNING: Do not attempt to 

access or change the setting of 

the fuel selection means.
Access  to  and  adjustment  of 

the fuel selection means must 

only be performed by a qualified 

service person when connecting 

this appliance to a specified fuel 

supply at the time of installation.
Change of the selector setting to 

other than the fuel type specified 

at the time of the installation 

could  damage  this  appliance 

and render it inoperable.
The  installer  shall  replace  the 

access cover before completing 

the  installation  and  operating 

this appliance.
IMPORTANT: Read this owner’s 

manual carefully and completely 

before  trying  to  assemble, 

operate, or service this heater. 

Improper use of this heater can 

cause  serious  injury  or  death 

from  burns,  fire,  explosion, 

electrical  shock  and  carbon 

monoxide  poisoning.  Failure 

to follow these instructions will 

void the warranty.
Only a qualified installer, service 

agent, or local gas supplier may 

install and service this product.

  WARNING:  Keep  the 

appliance  area  clear  and  free 

from  combustible  materials, 

gasoline, and other flammable 

vapors and liquids.
This  appliance  is  only  for  use 

with the type of gas indicated on 

the rating plate. This appliance 

is not convertible for use with 

other gases.

Содержание FBNSD400T-ZC Series

Страница 1: ...mmediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be perform...

Страница 2: ...of this manual WARNING Improper installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures...

Страница 3: ...low fans to blow directly into the heater Avoidanydraftsthatalterburner flame pattern including ceiling fans Altered burner patterns can cause sooting SAFETY WARNING Do not attempt to access or change...

Страница 4: ...oducts may create a white powder residue within burner box or on adjacent walls or furniture 8 Always run heater with control knob at PILOT IGN or ON 1 thru 5 positions never set control knob between...

Страница 5: ...h air PIEZO IGNITION SYSTEM This heater is equipped with an electronic piezo control system This system requires AAA batteries provided THERMOSTAT HEAT CONTROL The control automatically cycles the bur...

Страница 6: ...alth of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachuset...

Страница 7: ...erfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction methods help reduce...

Страница 8: ...nto adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation Air From...

Страница 9: ...or ash clean out doors located on floor or wall of fire place If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper WARNING Never install the h...

Страница 10: ...ill be pushed back by the fitting making all of the adjustments for the gas being supplied DO NOT REMOVE THE PLUNGER The regulator will not work and the warranty will be voided Theinletregulatoriscolo...

Страница 11: ...eshelf3 8 NPTpipe cap This will damage the plung ers located inside the regulator DO NOT TRY TO REMOVE THE PLUNGERS FROM INSIDE THE REGULATOR THE PLUNGER WILLBEPUSHEDBACKASTHE FITTINGISINSTALLED REMOV...

Страница 12: ...should not be less than 12 see Figure5 B Clearance from the top of the fireplace to the ceiling must not be less than 48 BUILT IN FIREPLACE INSTALLATION WARNING Do not allow any combustiblematerialsto...

Страница 13: ...standoff brackets in the hardware bag Remove screws from the top of the firebox Install brackets with screws as shown in Figure 10 3 Carefully set fireplace in front of rough opening with back of fir...

Страница 14: ...p is an acceptable al ternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice technician must connect heater...

Страница 15: ...f you do not reduce incom Figure 12 External Regulator with Vent Pointing Down External Regulator with Vent Pointing Down Propane Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Ni...

Страница 16: ...Ifbubblesform there isaleak Correctallleaksatonce PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect heater with its appliance main gas valve control v...

Страница 17: ...s very important to install the logs exactly as instructed Do not modify logs Use only logs supplied with heater Each log is marked with a number This number will help you to identify the logs when in...

Страница 18: ...ct For long periods of non operation remove batteries from all components for safety Unscrew ignitor cap and install a AAA battery with the pointing out Replace cap Figure 20 Installing Battery in Ign...

Страница 19: ...n under water FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS WARNING You must oper ate this heater with the screen in place Make sure screen is installed before running heater NOTICE Durin...

Страница 20: ...starting again 10 Make sure heater screen is in place before operating heater 11 If heater will not operate follow the in structions To Turn Off Gas To Appliance and call your service technical or ga...

Страница 21: ...ping follow instructions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the heater and burn causing brief patches of orange flame App...

Страница 22: ...irt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner Rep...

Страница 23: ...air through the air inlet hole You may blow through a drinking straw if compressed air is not available CABINET ODS PILOT Air Passageways Use a vacuum cleaner or pressurized air to clean Exterior Use...

Страница 24: ...pressure switch See instructions below The entire gas delivery piping including con nections inside the heater should be leak tested by the qualified installer After leak testing the qualified instal...

Страница 25: ...rn control knob to PILOT position 3 Fully press in control knob while pressing ignitor button 4 Continue holding down control knob Repeat igniting operation until air is removed 5 Clean ODS pilot see...

Страница 26: ...oo low 3 Gas regulator is defective 1 Check burner for dirt and debris If found clean burner see Care and Maintenance page 22 2 Contact local gas supplier 3 Replace gas train Slight smoke or odor duri...

Страница 27: ...noise is exces sive contact qualified ser vice technician White powder residue forming within burner box or on adjacent walls or furniture 1 When heated the vapors from furniture polish wax carpet cle...

Страница 28: ...www usaprocom com 200348 01C 28 PARTS MODEL FBNSD400T ZC 7 8 1 5 2 3 6...

Страница 29: ...page 30 of this manual ITEM PART DESCRIPTION QTY 1 161818 01HT Hood 1 2 161368 01HT Left Door Assembly 1 3 161369 01HT Right Door Assembly 1 5 161822 01 Gas Train Assembly 1 6 161338 01 Ignitor 1 7 1...

Страница 30: ...c at 1 866 573 0674 for information EQUIPMENT SHUTOFF VALVE For all models Equipment shutoff valve with 1 2 NPT tap Model and serial number of your heater How heater was malfunctioning Type of gas use...

Страница 31: ...ified heat propane gas supply might be low propane units only You may feel your gas pressure is too low If so contact your local gas supplier TECHNICAL SERVICE You may have further questions about ins...

Страница 32: ...rt s MUST be obtained through ProCom Heating Inc who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORTANT The heater MUST be...

Отзывы: