22 

OBSERVED PROBLEM                            PROBABLE CAUSE                                                  REMEDY

 

 
ODS/pilot lights but flame 
goes out when control knob 
is

 

released.

 

 
 

 

1.  Control knob is not fully   pressed 

in. 

2.  Control knob is not pressed in long 

enough. 

3.  Equipment shutoff valve is not fully 

open. 

4.  Thermocouple connection is loose. 
5.  Thermocouple damaged 
6.  Control valve damaged. 

 

1.  Press in control knob fully. 
 
2.  After ODS/pilot lights, keep control 

knob pressed in 30 seconds. 

3.  Fully open equipment shutoff valve. 
4.  Hand tighten until snug, and then 

tighten 

¼

 turn more. 

5.  Replace thermocouple. 
6.  Contact customer service.

 

 

Burner(s) does not light after 
ODS/pilot is lit. 

 

1.  Burner orifice is clogged. 
 
 
2.  Burner orifice diameter is too small.  
3.  Inlet gas pressure is too    low. 
 

1.  Burner orifice (see

 Care and 

maintenance

 Page 20) or contact 

customer service. 

2.  Contact customer service. 
3.  Contact your gas supplier.  

 
Delayed ignition of 
burner(s). 

 

1.  Manifold pressure is too low. 
2.  Burner orifice is clogged. 
 

1.  Contact your gas supplier. 
2.  Clean burner (see

 Care and 

maintenance

 Page 20) or Contact 

customer service. 

 

 
Burner backfiring during 
combustion. 

 

1.  Burner orifice is clogged or 

damaged. 

2.  Burner is damaged. 
3.  Gas regulator is damaged. 

1.  Clean burner orifice (see Care

 and 

maintenance

 Page 20) replace. 

2.  Contact Dealer or Customer Service. 
3.  Replace gas regulator.   
 

 
High yellow flame during 
burner combustion. 
 

1.  Not enough air. 
 
 
2.  Gas regulator is defective. 
3.  Inlet gas pressure is too low. 

1.  Check burner for dirt and debris. If 

found, clean burner (see 

Care and 

Maintenance

 Page 20).  

2.  Replace gas regulator. 
3.  Contact your gas supplier. 
 

 
Gas odor during combustion. 

1.    Foreign matter between 

control valve and burner. 

2.    Gas leak. (See Warning 

Statement at top of page 21). 

 

1. Take apart gas tubing and remove 

foreign matter. 

2. Locate and correct all leaks (see 

Checking Gas Connections

, page 14). 

 
 

 
 
 
 
 
 
 

Содержание BD23TCC-2-LO

Страница 1: ...TY This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion an...

Страница 2: ...x 23 000 BTU Hr 23 000 BTU Hr 23 000 BTU Hr 23 000 BTU Hr Input Min 14 000 BTU Hr 19 000 BTU Hr 14 000 BTU Hr 19 000 BTU Hr Gas Type Natural LP Propane Natural LP Propane Ignition Electronic Piezo Ele...

Страница 3: ...s that alter burner flame patterns which can cause sooting WARNING Do not use a blower insert heat exchange insert or other accessory not approved for use with this heater Due to high temperatures the...

Страница 4: ...Do not add extra logs or ornaments such as pine cones vermiculite or rock wool Using these added items can cause sooting Do not add lava rock around base Rock and debris could fall into the control ar...

Страница 5: ...ust be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy o...

Страница 6: ...approximately one 1 ounce 30ml of water for every 1 000 BTUs 3kWs of gas input per hour An unvented room heater is recommended as a supplemental heater a room rather than a primary heat source an enti...

Страница 7: ...of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are...

Страница 8: ...mum the space can support BTU hr actual amount of BTU hr used Example 51 200 BTU hr maximum the space can support 56 000 BTU hr actual amount of BTU hr used The space in the above example is a confine...

Страница 9: ...permanent openings one within 12 inches of the ceiling and one within 12 inches of the floor Connect these items directly to the outdoors or spaces open to the outdoors see figure 3 These spaces incl...

Страница 10: ...etc in the air exist may cause walls to discolor WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent free...

Страница 11: ...ed equipment shutoff valve with 1 8 in NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING Never c...

Страница 12: ...Hold gas regulator with wrench when connecting into gas piping and or fittings NG Models 5 in to 10 5 in W C Gas supplier provide external regulator for natural gas Purchase the optional CSA design c...

Страница 13: ...the width of a quarter and turn knob counterclockwise until the knob locks into the LP position see Figure 10 Selection valve must be locked into either the LP position or the NG position 3 Rotate and...

Страница 14: ...system Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected...

Страница 15: ...structions in this manual Flames contacting logs will create soot Figure 13 Installing Log Set IMPORTANT Make sure log does not cover any burner ports see Figure13 It is very important to install the...

Страница 16: ...s heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call...

Страница 17: ...ignitor button until pilot lights Note If pilot does not stay lit contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match 7 Keep control knob press...

Страница 18: ...rward 2 Follow steps 1 through 5 under Lighting Instructions 3 With Control Knob in PILOT position strike match and hold near pilot Press in Control Knob pilot should light 4 Keep Control Knob pressed...

Страница 19: ...ting page 21 23 BURNER FLAME PATTERN Figure 24 shows a correct burner flame pattern Figure 25 shows an incorrect burner flame pattern If pilot flame pattern is incorrect then Turn heater off see To Tu...

Страница 20: ...no greater than 30 PSI You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could d...

Страница 21: ...wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace electrod...

Страница 22: ...tomer service 3 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and maintenance Pa...

Страница 23: ...furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products He...

Страница 24: ...r Service or your dealer have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we w...

Страница 25: ...1 FBB28D01 B Burner Assembly 1 2 NDD0308 400 DF ODS 1 3 SIT545 200 T Stat Valve Assembly 1 4 AL092 01 PIMSC1 01 Piezo Ignitor 1 5 RV83FI 4 9 DF Regulator 1 6 YDF06 BD23T Gas Selection Valve Assembly 1...

Страница 26: ...ront Panel Left 1 1 6 BD230T104 Lower Front Panel Right 1 1 7 BD230T109 Door 1 1 8 BD230T005 Decorative Trim Assembly 1 1 9 BD230T003 Firebox Assembly 1 1 10 BD230T004 Louver Assembly 1 1 11 BD230T201...

Страница 27: ...27 Printed in China...

Отзывы: