background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOVA SERIES 

MCT466 QuikCheck 

RUGGED NIR TESTER FOR USE AT LINE

 

USER GUIDE MANUAL 

 

Process Sensors Corporation 

113 Cedar Street Milford MA 01757 USA 

www.processsensors.com

 

Tel. (508) 473 – 9901 

Содержание MCT466-QC

Страница 1: ...NOVA SERIES MCT466 QuikCheck RUGGED NIR TESTER FOR USE AT LINE USER GUIDE MANUAL Process Sensors Corporation 113 Cedar Street Milford MA 01757 USA www processsensors com Tel 508 473 9901...

Страница 2: ...MCT466 QC User Guide Manual Process Sensors Corporation Page 2 PAGE INTENTIONALY LEFT BLANK...

Страница 3: ...rbygate Business Park Corby Northants NN17 5JG UK Tel 44 015 36408066 Fax 44 015 36407813 infouk processsensors com Eastern Europe Process Sensors Polska Dr Ing Tomasz Stachowiak ul Erazma z Zakroczym...

Страница 4: ...rporation expressly disclaims any warranty for merchant ability or fitness for a particular purpose Unless otherwise agreed in writing by the Corporation repairs and replacement parts provided by the...

Страница 5: ...ce SUI 3 2 1 Initiating a Test 3 2 2 Changing Product Codes 3 2 3 User Screen 3 2 4 Menu Protection Password 3 2 5 Menu Selections 3 2 6 Calibration Parameters 3 2 7 Calibration Routine 3 2 8 Diagnost...

Страница 6: ...oned and then used to calibrate the MCT466 QC NIR tester 6 Accessories This section lists the different accessories which could be used along with the MCT466 QC NIR tester 7 Technical Specifications T...

Страница 7: ...sing light through NIR measurement and reference filters within a rotating wheel An internal and external voltage signal is generated for each filter the latter results from collection of back scatter...

Страница 8: ...d and visible filters are held in a circular disc A single timing notch is machined in the edge of the disc 3 1 3 Filter Wheel Motor A precision brushless DC motor is used to accurately rotate the fil...

Страница 9: ...ster The SUI is made up of 2 major components a 5 7 high resolution touch screen and a single smart circuit board The SUI is located at the front of the tester on the base of the tester Below are some...

Страница 10: ...the hand symbol located in the top right corner of the SUI When test is initiated the MCT466 QC NIR tester will go through the following testing stages Stage 1 Initializing In this stage the turn tab...

Страница 11: ...ts sampling to measure the moisture level in the sample Sampling time could be changed by changing the sample time Figure 6 Tester s SUI during sampling stage Stage 3 Sample Complete In this stage sam...

Страница 12: ...orner of the main screen will allow you to access an unprotected User Screen as shown in Figure 11 below In this screen the user may offset the NIR tester s zero setting change the damp time and chang...

Страница 13: ...Menu Protection Password To access the NIR tester setup menu touch the blue pad next to ENTER SETUP on the LCD The Password request screen will pop up Enter the correct password and touch the ENTER ke...

Страница 14: ...ections After entering the correct Password the Select Menu will be presented The select menu consists of two pages Page 1 of the user menu is shown in Figure 13 below and page 2 of the user menu is s...

Страница 15: ...below The display will present the product calibrations saved in the NIR tester You can simply select the product calibration by touching it Touch the right arrow on the top right corner to see the c...

Страница 16: ...phical relationship between the tester s reading and the true moisture value of a series of samples as shown in Figure 17 below Figure 17 Calibration Graph Calibration Routine Process 1 Select one of...

Страница 17: ...isture value for the first sample 9 Touch the MCT Value displayed in blue on the LCD and enter the NIR tester reading for the first sample 10 Repeat this procedure for all the samples 11 When all samp...

Страница 18: ...Less than 0 9 is not acceptable Standard Error This is an indication of the accuracy of the calibration A perfect value is 0 0 Acceptable values are in the 0 0 to 0 5 range depending on the moisture r...

Страница 19: ...heel Internal Temperature This is the internal temperature of the MCT466 QC NIR tester Filter Gain This is the optical circuitry gain value Cooler Temperature This is the actual detector s temperature...

Страница 20: ...els for the six filters that may be fitted to the filter wheel in the MCT466 QC NIR tester Values are given for both external and internal filters A bar graph comparison for each filters INT and EXT v...

Страница 21: ...9 9 Above 9 9 High signals 5 V 5 00 4 8 5 2 Outside Min Max VCC Fault 15 V 15 00 14 0 16 0 Outside Min Max VP Fault 15 V 15 00 14 0 16 0 Outside Min Max VN Fault Motor Speed 1500 950 3500 Outside Min...

Страница 22: ...l other customization functions of the NIR tester Please note that this menu should only be accessed by people experienced in the setup of the MCT466 QC NIR tester for specific applications Also the e...

Страница 23: ...ey are as follows 1 AGC Engineering Page This submenu helps the user control the MCT466 QC signal s gain for better performance The Gain is also presented in the diagnostics menu to help balancing the...

Страница 24: ...not reflect well and will need a higher pre gain setting Very white or light products reflect light well and will need a lower pre gain setting The Pre Gain has four manually adjustable settings Pre...

Страница 25: ...ituents Engineering page Below in Figure 27 is a screen shot of the Constituents settings page This engineering page allows the end user to enable and or disable constituents change the reading type t...

Страница 26: ...QC NIR tester to readout using a logarithmic calculation Lin Mode This changes the linear regression calibration to a look up table calibration 4 Constants Engineering Page The constants page shown in...

Страница 27: ...ow many times the CPU s timing clock goes out of tolerance 3 4 Digital Outputs The MCT466 QC provides a choice of serial output formats RS232 RS485 and USB RS232 is suitable for a single NIR tester to...

Страница 28: ...ne in the production environment as shown in Figure 31 below Figure 31 MCT466 QuikCheck being used in a laboratory environment 4 2 Temperature The MCT466 QC NIR Tester is designed to give satisfactory...

Страница 29: ...ing the correct moisture values The standards may be used in two ways a As a quick low high check of the tester s reading In this manner it allows users to gain confidence in the stability of the test...

Страница 30: ...ke the MCT466 QC NIR tester read the 2 0 and 8 0 values As the Cal Development routine requires 3 data pairs one set of values needs to be entered twice Finally store this zero span value in the CAL C...

Страница 31: ...ressed steel angled holder with circular cut out and passive reflector on the bottom surface 5 3 Sample Bowl There are different sizes sample bowls due to the diverse physical structure and shape of t...

Страница 32: ...e a thermal balance on a 10g sub sample to establish the approximate moisture level Calculate the grammage of moisture that needs to be added to achieve the required moisture levels Place the conditio...

Страница 33: ...ration Codes 200 Power 90 260VAC 50 60 Hz 40 watts Construction Hygienic Polycarboante Ambient Temperature 0 50 C 32 120 F Accuracy Moisture 0 1 Coatings 0 1 gr m Fats Oils 0 2 Repeatability 0 2 Smart...

Страница 34: ...d change the old password To use this backdoor system proceed as follows At the Password request enter the number 6811 and then press ENTER This will allow access to the SETUP SELECT Menu then select...

Страница 35: ...the Dry Basis 2 An asterisk appears in front of the Moisture word in the display to alert users that the tester is in the DRY mode 3 The Calibration routine is modified to allow dry basis values to be...

Страница 36: ...bration and Set Up Parameters Password needed Parameter Moisture Constit 1 Constit 2 Zero 20 0 40 0 20 0 Span 25 0 50 0 25 0 Damping 1 1 1 Cooler Target 20C Pre Gain X1 Password 0000 Inst ID 9 Digits...

Страница 37: ...age 37 Constituents Moisture ON Atro OFF Log OFF Constituent 2 OFF Log OFF Constituent 3 OFF Log OFF Temperature OFF Constants Moisture Constituent 2 Constituent 3 K1 1 0 K6 1 0 K4 1 0 C2 0 3 C5 1 0 C...

Отзывы: