Fig. 94 - Configuration of the modules
13.6
PN/PN coupling or Proxy mode
A unique feature of the PND-001 module is that it can be used as a PN/PN coupler for up to 10 networks. It
connects the networks on an I/O level, where you can decide how many bytes need to be transferred. For each
network a PND-001 is needed. So if you wish to connect 2 networks, you need 2 PND-001 modules in one
ComBricks set.
A typical ComBricks configuration for a PN/PN setup may look like this:
Fig. 95 - ComBricks configuration screenshot of the web server
Slot 1 belongs to Network 1. Slot 2 is connected to Network 2. These networks can now be coupled via the
configuration tools of each master. For example, if you want to transfer 1 byte, the setup for the configuration
tool of network 1 will look as follows:
The first slot is used for the PND-001 module. The next slot is used for anther PND-001 module, but a proxy
module must be selected because the PND-001 itself does not have any I/O. The setup for the second network
will look as follows:
i 10..13
Q 10..13
i 20..23
Q 20..23
Network 1
Network 2
Sl
ot
1
Sl
ot
2
Example layout
Fig. 96 - Schematic representation of the proxy
Содержание ComBricks
Страница 1: ...User Manual ...
Страница 132: ...ComBricks User Manual v6 4 0 January 18 PROCENTEC 132 219 ...
Страница 213: ...ComBricks User Manual v6 4 0 January 18 PROCENTEC 213 219 44 Certificates ...
Страница 214: ...ComBricks User Manual v6 4 0 January 18 PROCENTEC 214 219 ...
Страница 215: ...ComBricks User Manual v6 4 0 January 18 PROCENTEC 215 219 ...
Страница 216: ...ComBricks User Manual v6 4 0 January 18 PROCENTEC 216 219 ...
Страница 217: ...ComBricks User Manual v6 4 0 January 18 PROCENTEC 217 219 45 Notes ...
Страница 218: ...ComBricks User Manual v6 4 0 January 18 PROCENTEC 218 219 ...