Pre-Installation (continued)
HARDWARE KIT
NOTE:
Hardware
not
shown to actual size.
AA
BB
CC
Part
Description
Quantity
AA
Wire nut
3
BB
Allen key
1
CC
Junction box gasket
1
PACKAGE CONTENTS
Part
Description
Quantity
A
Light protection globe
1
B
Cast junction box
1
C
Globe wire guard
1
D
Heat sink
1
E
Wall mount arm
1
Installation
1
For best results
Direct to Wall Mount/
Junction Box
B
A
C
E
D
2
Shut electric power off
(fig 1).
(fig 2).
(fig 3).
☐
The fixture can be mounted in the
following two ways:
A. Direct to Surface / Junction Box
: This
fixture includes an external junction box
to mount anywhere. Fixture can also be
mounted on top of recessed junction
box (may requiring tapping hole in
fixture base or drilling holes on surface
outside of internal junction box.)
B. Side Conduit Surface Mount
: The
fixture can also be mounted directly
on the wall surface using side conduit
entries.
☐
Install light 8-15 feet above the ground.
☐
When installing two fixtures on one
switch, make sure the switch is rated for
at least a 1A inductive load.
☐
Do NOT wire to dimming switch.
☐
At wall switch verify it is in the off posi-
tion (fig 1).
☐
At the main electrical panel turn off the
circuit breaker that supplies power to
the outlet box you are working on (fig
2).
☐
For screw-in type fuses unscrew the
fuse that supplies power to the outlet
box you are working on (fig 3).
Side Conduit Entry
Conduit
Pipe