9
PROBRITE.COM
Please call 1-844-507-5651 or email [email protected] for further assistance.
8
Visit
www.probrite.com/install
for installation video tutorials and product support
D
C
Installation (continued)
Installation (continued)
7
Securing the light fixture on the mounting
base and caulking
NOTICE:
Failure to properly caulk around the
surface and mounting plate (D) could lead
to water damage and is not covered under
warranty.
NOTE:
When attaching this fixture (A) to an
external surface mount junction box, caulk the
inside of the light fixture before attaching to the
mounting plate (D).
(fig 3).
BB
D
(fig 2).
(fig 1).
Surface Conduit Mount
☐
Remove desired conduit plug from one
of the fixture's sides from the where
conduit will enter. (Fig. 2)
☐
Make wiring connections inside the
fixture as per the instructions given
below.
☐
If necessary, strip 3/8" of insulation
from junction box or fixture (A) wires
(fig 1).
ON/OFF Wiring (Non Dimming) Method:
☐
Connect fixture black wire to house
black wire, the (+) line, and fixture
white wire to house white wire, the (-)
common by twisting the exposed wires
together and using the wire nuts (BB).
Ensure no loose wires.
☐
Connect house ground wire to the
green fixture ground wire, by twisting
the exposed wires together and using
the wire nuts (BB).
Conduit
☐
To enable dusk-to-dawn remove the
black opaque cap cover (F) installed
on the fixture and replace it with
clear cap cover (CC). Also ensure the
photocell (E) is unobstructed.
☐
Ensure the switch powering the outlet
connected to the light fixture is turned
to the ON position and
leave it ON
at all times to enable dusk-to-dawn
functionality to operate automatically.
NOTE:
If photocell (E ) is located in an area
under heavy shade the photocell may not
detect enough light and may turn the light
fixture on.
TIP:
To test if the light fixture (A) and pho-
tocell (E) works properly run power to the
fixture and cover the photocell to turn fixture
ON. Shine a light into the photocell to see if
fixture turns OFF.
A
F
(Clear cap cover on photocell for
Dusk-to-Dawn Operation)
Operation
1
Selecting Dusk-to-Dawn or
Switch-Controlled
OPTION 1: DUSK-TO-DAWN OPERATION
Dusk-to-dawn operation enables the light fixture to automatically turn
ON when dark outside and turn OFF when the sun rises, thus saving you
energy.
☐
Close the fixture by tightening the two
mounting base tightening screws (C),
using a philips screwdriver, which were
removed earlier in Step 1. (Fig. 1)
☐
Caulk around the mounting plate (D)
and surface with silicone sealant (not
included).(Fig. 1)
LIGHTING
FIXTURE
(+) LINE
(-) COMMON
GROUND
BLACK
WHITE
GREEN
0-10V Dimmable Wiring Method:
☐
Connect fixture black wire to house
black wire, the (+) line, and fixture
white wire to house white wire, the (-)
common by twisting the exposed wires
together and using the wire nuts (BB).
Ensure no loose wires.
☐
Connect house ground wire to the
green fixture ground wire, by twisting
the exposed wires together and using
the wire nuts (BB).
☐
Connect the purple wire to the (V+)
DIM wire and the gray wire with (V-)
DIM wire by twisting the exposed wire
together and using the wire nuts (BB).
LIGHTING
FIXTURE
(+) LINE
(-) COMMON
(+)DIM V+
BLACK
WHITE
PURPLE
GROUND
GRAY
GREEN
(-)DIM V-
(Non-Dimming Wiring Diagram)
(0-10V Dimming Wiring Diagram)
AUTOMATIC
NIGHTTIME ON
DAYTIME OFF
TIP:
Hold stripped ends near each other and
align any frayed strands (do not twist wires).
Push the wires into wire nut (BB) and use your
fingers to twist the wire nut clockwise until tight.
Check for tightness by pulling wires.
Swap
CC
E