1.1 CONTROL PANEL
1. Connect the power cord to the power socket located on the rear panel, turn on the power switch (SW1),
then push the PB1 button, the PB1’s LED should light up indicating power supply is ok.
﹡
Please make sure the E-Stop button is not pressed/activated before usage. All controls become
invalid when E-Stop button is pressed.
2. S2 ( WELD / TEST ) Switch enable / disable welding source activation output.
3. S3 ( AUTO / MANU ) Switch select the operation mode.
Manual ( MANU )
:
Turn table rotation is controlled by the foot switch
Automatic ( AUTO)
:
The start of the rotation is activated by the foot switch, the duration of the rotation and
is controlled by the ( TIMER ) knob on the front panel from for a duration of (0~60
second).
4. S4 (
← / → ) Direction switch select the direction of rotation (clockwise or counterclockwise.)
5. S5 ( WELD / RAPID ) Switch select the operating
Welding speed ( WELD )
:
Turn table rotation speed can be adjusted from
(
WELD SPEED
)
knob on the
front panel.
Full speed (RAPID)
:
Turn table rotation speed is set at full speed.
﹡
Press E-Stop button in case of any emergency situation. All motion and procedure would stop
immediately. Reset the E-Stop button and push PB1 again after clearing the emergency
situation to return the system to operation mode
.