Safety Instructions

 will provide years of service if it is properly 

maintained as any electric and/or mechanical equipment requires. 

Please pay careful attention to the following important information 

regarding the care, maintenance, and operation of the patient lift.  

Carefully read these instructions before assembling the lift, or 

attempting to lift a user with the device. 

• Before attempting to lift any patient, please practice operating the lift

and explain the lift procedures to the patient

• Please provide special assistance under the caretakers’ discretion.

(i.e. patients who are comatose, spastic, agitated, or otherwise

severely handicapped)

• The patient lift should be used solely for transferring a user/patient

from one utility (beds, chairs, toilets, etc.) to another.  The patient lift

should not be used for transporting or moving any patient from one

location to another location.

• During lifting or lowering, whenever possible, always keep the base

of the lift in the widest position.

• The base of the lift should be closed before moving the lift.

• Do not roll casters over any object while the user/patient is in the

sling.

• Do not lock casters during lifting.

• While being lifted in a sling, always keep the user/patient centered

over the base and facing the caregiver operating the lifter.

• Never leave the user/patient unattended during lifting.

Содержание Protekt Take-A-Long 33400P

Страница 1: ...structions in this manual All operators should read and understand the instructions for safe and proper operation of the patient lift Folding Position 1 Flat Folding Position 2 Standing PROTEKT TAKE A...

Страница 2: ...wing information for future use Supplier Name ___________________________________________ Supplier Telephone ________________________________________ Product Serial Number ____________________________...

Страница 3: ...optional battery pack you will never have to be worried about your lift not being charged and ready for use The is intended to be used with patients who are completely immobile or totally dependent o...

Страница 4: ...e into physical contact with the pa nt in order for the device to carry out its intended Do Not Iron Item may not be smoot ed or ed with an iron Class II symbol To iden y equipment is designed that a...

Страница 5: ...patients who are comatose spastic agitated or otherwise severely handicapped The patient lift should be used solely for transferring a user patient from one utility beds chairs toilets etc to another...

Страница 6: ...ntact with any part of the equipment WILL NOT cause skin irritation allergic reaction etc Using accessories detachable parts or materials not described in the instruction manual MAY RESULT IN SERIOUS...

Страница 7: ...ncy Lowering 4 Leg Opening Pedal 9 Emergency Stop Bu on Charger 0 6 lb 0 3 kg 5 Base 10 Control Unit 11 lb 5 kg Combined Weight 1 5 67 2lb 30 5 kg UNLESS OTHERWISE SPECIFIED SHEET SCALE PART NUMBER DE...

Страница 8: ...1041mm C Base External Width Closed 25 6 650mm D Base Internal Width Opened 32 0 813mm E Mast Height 48 3 1227mm F Front Caster Height 4 7 119mm G Li ing Height Lowest 18 5 465mm H Li ing Height Highe...

Страница 9: ...in that is securing the mast Step 4 by grabbing onto the handle bars Step 2 Secure the stand to the mast Make sure the tab on the standing bracket sit in the top hole on the mast and insert the screw...

Страница 10: ...Step 5 Insert the pin to secure the mast Step 6 Remove the pin that is securing the boom Step 7 Remove lower actuator pin...

Страница 11: ...l the lower end of the actuator as follows It is critical to have the motor part of the actuator to face the same direction as the big arrow as follows Step 9 Install the upper end of actuator and rei...

Страница 12: ...AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BESTCARE LLC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BESTCARE LLC IS PROHIBITED 9 2...

Страница 13: ...Step 1 Spreader bar at lowest position Step 2 Folding the boom Step 3 Folding the mast Step 4 Standing position 1 1 2 2 3 3...

Страница 14: ...ients doctor nurse or medical attendant select a sling that is both practical and comfortable The sling selected should be one that serves the needs of the patient while providing the patient with opt...

Страница 15: ...ger cord that may cause strangulation if used improperly Keep long charger cord out of walkway where it poses a tripping hazard Have the charger port on the controller facing away from the wall for ea...

Страница 16: ...ing charging the LCD Display Panel will show one of the four signs below The DC Charger must be connected The emergency stop button must be released The battery will not be charged if the emergency bu...

Страница 17: ...1 LED Indicator Green In Use Blank Standby Lifting Lowering Operating Lift Using Hand Control Operating Lift Using LCD Display Panel...

Страница 18: ...isplay Panel will show the sign on the left either when the emergency stop button is released or when a button on the LCD Display Panel is pressed Lift operation is deactivated Battery needs to be cha...

Страница 19: ...full body large 600lb weight capacity 30124 X Large Mesh full body X large 600lb weight capacity 30118 XX Large Mesh full body XX large 600lb weight capac y ITEM DESCRIPTION 30114 Medium Mesh full bod...

Страница 20: ...ded divided leg w o head support small 600 lb weight capacity 30100 NHS Medium Solid padded divided leg w o head support medium 600 lb weight capacity 30101 NHS Large Solid padded divided leg w o head...

Страница 21: ...2 Hook up E Insert F through E 8 Strap Sling A B G H C D E F Hook up A C Hook up B D Hook up E Hook up F Hook up H Hook up G Insert H th Point 1 Hook up A C E Point 2 Hook up B D F Point 1 Hook up H...

Страница 22: ...from bed Position user over the wheelchair or chair then lower the patient onto the surface 11 Reverse the above procedures when returning the user patient to bed Grasp the sling at each corner of th...

Страница 23: ...ime of the electrical components are 3 years Contact for any recycling information First Received Monthly Every 3 Months Check connections between boom and spreader bar for improper connection Check c...

Страница 24: ...soap or isopropyl alcohol For slings with rigid supports remove the plastic inserts before washing Look for an opening near the plastic inserts for removal Machine wash warm or cold Do not wash with...

Страница 25: ...g on usage The actuator will either go up or down but not both Replace your hand control as it is at the end of its life cycle Your control box may be malfunctioning There is a grinding sound inside t...

Страница 26: ...of the actuator shaft It is intended for use if the actuator or electronics fail to operate while the patient is suspended in midair wise continually until the patient has been lowered NOTE THE EMERG...