background image

Ensure the product has been assembled according to the instructions in this 

manual. All operators should read and understand the instructions for safe 

and proper operation of the patient lift.

PROTEKT® 

ALL-IN-ONE

UNIVERSAL PORTABLE ELECTRIC PATIENT LIFT

M o d e l :

  3 3 3 5

0

Содержание PROTEKT 33350

Страница 1: ...ed according to the instructions in this manual All operators should read and understand the instructions for safe and proper operation of the patient lift PROTEKT ALL IN ONE UNIVERSAL PORTABLE ELECTR...

Страница 2: ...wing information for future use Supplier Name ___________________________________________ Supplier Telephone ________________________________________ Product Serial Number ____________________________...

Страница 3: ...ional battery pack you will never have to be worried about your lift not being charged and ready for use The 33350 is intended to be used with patients who are completely immobile or totally dependent...

Страница 4: ...o physical contact with the pa ent in order for the device to carry out its intended use Do Not Iron Item may not be smoothed or nished with an iron Class II symbol To iden fy equipment is designed th...

Страница 5: ...ho are comatose spastic agitated or otherwise severely handicapped The patient lift should be used solely for transferring a user patient from one utility beds chairs toilets etc to another The patien...

Страница 6: ...ntact with any part of the equipment WILL NOT cause skin irritation allergic reaction etc Using accessories detachable parts or materials not described in the instruction manual MAY RESULT IN SERIOUS...

Страница 7: ...ld not be put into use until all connections are tightened using standard tools Easy Tools Screwdriver 7 5 lb 3 4 kg 11 lb 5 kg 0 7 lb 0 6 lb 0 3 kg 0 3 kg 8 4 lb 3 8 kg 5 Spreader Bar 6 Rear Caster 1...

Страница 8: ...2 68 1 B 1070 8 42 2 C 658 4 25 9 D 492 2 19 4 E 812 8 32 0 F 766 9 30 2 G 576 7 22 7 H 333 3 13 1 I 496 9 19 6 J 275 10 8 K 442 7 17 4 L 118 5 4 7 M 20 3 0 8 N 1170 7 46 1 O 658 7 25 9 P 376 4 14 8 3...

Страница 9: ...ht Highest 64 7 1643 mm H Base Opened Turning Diameter 55 7 1414 mm I Base Closed Turning Diameter 51 2 1300 Input Voltage 220 240VAC 50Hz 110 120VAC 60Hz Output Voltage 24 VDC Battery Pack 24 VDC 5AH...

Страница 10: ...hole on the stand bracket with the lower hole on the mast Make sure the tab on the stand bracket insert into top hole on the mast and insert the screw to secure the stand bracket as follows Step 3 Re...

Страница 11: ...om Step 7 Remove lower actuator pin on the mast Step 8 Move the boom out of the way and install the lower end of the actuator to the mast using a pin and retaining ring as follows It is critical to ha...

Страница 12: ...d of actuator to the boom by reinserting the quick release pin to secure it Step 10 Insert the spreader bar into the tube on the boom as follows Align the holes and secure the spreader bar using a pin...

Страница 13: ...12 4 3 2 1 5 M5 SCREWS M4 SCREWS...

Страница 14: ...Step 1 Remove The Spreader Bar WARNING Step 2 Detach The Actuator 13 1 2 1 2 13...

Страница 15: ...Step 3 Fold Up The Boom Step 4 Fold Up The Mast 14 1 2 3 1 2 3...

Страница 16: ...Standing Up Lying Down 15...

Страница 17: ...octor nurse or medical attendant select a sling that is both practical and comfortable The sling selected should be one that serves the needs of the patient while providing the patient with optimal sa...

Страница 18: ...cord that may cause strangulation if used improperly Keep long charger cord out of walkway where it poses a tripping hazard Have the charger port on the controller facing away from the wall for easy...

Страница 19: ...g charging the LCD Display Panel will show one of the four signs below The DC Charger must be connected The emergency stop button must be released The battery will not be charged if the emergency butt...

Страница 20: ...LED Indicator Green In Use Blank Standby Lifting Lowering Operating Lift Using Hand Control Operating Lift Using LCD Display Panel 19...

Страница 21: ...play Panel will show the sign on the left either when the emergency stop button is released or when a button on the LCD Display Panel is pressed Lift operation is deactivated Battery needs to be charg...

Страница 22: ...l Purpose Clip Sling w Padded Legs Polyester Medium MAA4000M M General Purpose Clip Sling w Padded Legs Polyester Large MAA4000M L General Purpose Clip Sling w Padded Legs Polyester XLarge MAA4000M XL...

Страница 23: ...oint 4 Hook up D 1 3 2 4 B A C D 22 dealer Slide the clip over the sling hook on the spreader bar through the hole Pull down the clip to lock the sling on to the spreader bar Sling Hook Sling Clip EAC...

Страница 24: ...edures when returning the user patient to bed 1 Help the user lean forward slightly then slide the sling down between the chair and the user s back 2 Position the commode aperture where the buttocks m...

Страница 25: ...re positioned midway under the thighs to provide good support and greater comfort 8 Position the boom to the proper height to extend the spreader bar into the car without hurting the patient or the ca...

Страница 26: ...rior to use for the additi inspection interval and the visual inspection points are listed below Note Bestcare assumes that the assembly instructions were performed properly and by a qualified individ...

Страница 27: ...ent uses we recommend wipes with water soluble soap or isopropyl alcohol For slings with rigid supports remove the plastic inserts before washing Look for an opening near the plastic inserts for remov...

Страница 28: ...n usage The actuator will either go up or down but not both Replace your hand control as it is at the end of its life cycle Your control box may be malfunctioning There is a grinding sound inside the...

Страница 29: ...the actuator shaft It is intended for use if the actuator or electronics fail to operate while the patient is suspended in midair wise continually until the patient has been lowered NOTE THE EMERGENC...

Страница 30: ...WARRANTY POLICY All In One 29...

Страница 31: ...com...