Terminal Designations

This thermostat is shipped from the factory to operate a conventional heating

and cooling system. This thermostat may also be configured for a heat pump 

system. See the “heat pump” configuration step on page 16 of this manual to 

configure the thermostat for heat pump applications.

Wiring

Terminal

2 Heat 2 Cool

Conventional 

System

2 Heat 1 Cool

Heat Pump 

System

 4 Heat 2 Cool

Heat Pump 

System

RC

RH

C

B

O

G

W/E

Y

Y2

W2

Transformer power

(cooling)

Transformer power

(heating)

Transformer 

common

Fan relay

First stage

of heat

First stage 

of cool

Second stage 

of cool

Second stage 

of heat

Transformer power

(cooling)

Transformer power

(heating)

Transformer 

common

Fan relay

 

Emergency Heat

First stage of 

heat & cool

N/A

Auxiliary heat 

Transformer power

(cooling)

Transformer power

(heating)

Transformer 

common

Wiring

Caution: 

Electrical Hazard

All components of the control 

system and the thermostat 

installation must conform to 

Class II circuits per the NEC Code.

Warning:

Do not overtighten terminal 

block screws, as this can 

damage the terminal block.  

A damaged terminal block 

can keep the thermostat 

from fitting on the subbase 

correctly or cause system 

operation issues.

Installation Tip

Max Torque = 6in-lbs.

Wiring

If you are replacing a thermostat, 

make note of the terminal 

connections on the thermostat that 

is being replaced.  In some cases 

the wiring connections will not be 

color coded. For example, the 

green wire may not be connected 

to the 

G

 terminal.

Loosen the terminal block screws. 

Insert wires then retighten the 

terminal block screws.

Place nonflammable insulation into 

the wall opening to prevent drafts.

1.

2.

3.

Wiring Tips

C Terminal

This thermostat requires a 24V 

common wire to the C terminal.

Wire Specifications

Use shielded or non-shielded 18-22 

gauge thermostat wire.

Failure to disconnect the power 

before beginning to install this 

product can cause electrical shock 

or equipment damage.

Note:

In many heat pump systems with 

no emergency heat relay, a jumper 

can be installed between 

E

 and 

W2

 to turn thermostat into a single 

stage control for Emergency Heat 

Operation.

9

10

11

12

Wiring Diagrams

Wiring Diagrams

Typical 2H/2C System: 1 Transformer

Typical 2H/2C System: 2 Transformer

Typical Heat Only System With Fan

Typical Cool-Only System With Fan

FAN RELAY

HEAT RELAY

RC
RH

Y
C

W/E

G

C

R

L2

L1

(HOT)

FAN RELAY

COMPRESSOR 

RELAY

C

R

L2

L1

(HOT)

RC

RH

Y
C

G

Power supply
Factory-installed jumper.  Remove only when installing on 2-transformer systems

Use either O or B terminals for changeover valve
A 24 VAC common connection is required with this thermostat.

W/E

REMOVE JUMPER 

RC
RH

Y
C

W/E

G

W2

Y2

C

R

L2

L1

(HOT)

C

R

L2

L1

(HOT)

COMPRESSOR

RELAY

HEAT RELAY

FAN RELAY

RC
RH

Y
C

W/E

G

W2

Y2

COMPRESSOR

RELAY

FAN RELAY

HEAT RELAY 2

COMPRESSOR

RELAY 2

HEAT RELAY

C

R

L2

L1

(HOT)

S1/S2

Remote Sensor

Remote Sensor

Note:

In many systems with no emergency heat relay a jumper can be installed 

between E and W2.

Outdoor temperature sensor, Indoor temperature sensors, and Slab sensor 

wiring diagrams are located in R250S and R251S manuals. 

Note:

H

Humidify

Humidify

D

Dehumidify

Dehumidify

Fan relay

Second stage of 

auxiliary heat

Remote Sensor

Humidify

Dehumidify

First stage of 

auxiliary heat

First stage of 

heat & cool

Second stage 

of heat & cool

 5 Heat 3 Cool

Heat Pump

System

Transformer power

(cooling)

Transformer power

(heating)

Transformer 

common

Fan relay

Second stage of 

auxiliary heat

(5th stage of heat)

Remote Sensor

Humidify

Dehumidify

First stage of 

auxiliary heat

(4th stage of heat)

First stage of 

heat & cool

Second stage 

of heat & cool

Reversing valve / 

3rd stage of heat 

& cool

Reversing valve / 

3rd stage of heat 

& cool

Reversing valve 

/ configurable 

terminal

Reversing valve 

/ configurable 

terminal

Reversing valve 

/ configurable 

terminal

Reversing valve 

/ configurable 

terminal

Reversing valve 

/ configurable 

terminal

Reversing valve 

/ configurable 

terminal

HEAT RELAY 2

COMPRESSOR

RELAY 2

Typical 2H/1C Heat Pump System

RC
RH

Y
C

W/E

G

W2

B

COMPRESSOR

RELAY

FAN RELAY

EMERGENCY

HEAT

C

R

L2

L1

(HOT)

O

COOL 

CHANGEOVER 

VALVE

HEAT 

CHANGEOVER 

VALVE

If DEHUM relay requires a normally-energized input, set Dehumidify relay to NC 

in Technician Setup.

Содержание T855iSH

Страница 1: ...all 4 Wires should be pushed into the wall Installation Tips The thermostat should be installed approximately 4 to 5 feet above the floor Select an area with average temperature and good air circulati...

Страница 2: ...e the bevel on lower ridge Day of theWeek Setpoint Indicator Displays the user selectable setpoint temperature Energy Efficient Globe Indicates the setpoint temperature chosen is a efficient choice In...

Страница 3: ...gency heat relay a jumper can be installed between E and W2 to turn thermostat into a single stage control for Emergency Heat Operation 9 10 11 12 Wiring Diagrams Wiring Diagrams Typical2H 2CSystem 1T...

Страница 4: ...nd stage will turn on at 2x the swing setting The second stage will turn off when 1x the swing is reached For example if the swing setting is 5 degrees for heating and the thermostat is set at 70 F th...

Страница 5: ...pump applications OF DUAL FUEL Use the and buttons to select ON OFF SET STAGES 2H2C PROGRAM 7d 4 TIME PERIODS PRO RECOVERY This setting maximizes efficiency and equipment longevity by increasing the h...

Страница 6: ...iods is set to 2C or 4C Use the and buttons to adjust Pre Occupancy Fan Youcanselectthe pre occupancyfanfromOFF 1 2 or3hours If1 2 or3 isselected thefanwillturn onthatmanyhourspriorto thescheduledoccu...

Страница 7: ...lect OFF 10 15 20 25 30 35 40 45 50 degrees OFF BALANCE POINT OF Balance point with electric auxiliary will optimize heat pump usage When the outdoor temperature is above the AUX CUT OUT selection the...

Страница 8: ...an explanation of these options 1 1 DUM Terminal Onlyshowsif dehumidifyis setto ON DUM TERMINAL HUM Terminal DHM Terminal OPTIONS 1 2 3 4 HUM terminal energizes when the ambient humidity is Below the...

Страница 9: ...64 6 65 4 66 4 67 4 68 2 68 2 68 9 69 2 65 3 66 2 67 2 68 2 69 1 69 1 70 70 1 66 67 68 69 70 70 71 71 67 2 68 2 69 1 70 1 71 1 71 4 72 4 72 6 68 3 69 3 70 3 71 3 72 3 72 8 73 8 74 3 69 7 70 7 71 7 72...

Страница 10: ...ng 1 Select HEAT or COOL with the SYSTEM key Note You have to program heat and cool each separately 2 Press the MENU button If menu does not appear first press RUN SCHED 3 Press SET SCHED Note Monday...

Страница 11: ...F 17 C 70 F 21 C 62 F 17 C 78 F 24 C 85 F 28 C 78 F 24 C 82 F 26 C 78 F 24 C 85 F 28 C 78 F 24 C 82 F 26 C 78 F 24 C 85 F 28 C 78 F 24 C 82 F 26 C Programming Factory Default Program for 2 Time Period...

Страница 12: ...g 802 11 B G N Standards 45 46 Specifications Remote Sensor Operation Option 1 Indoor Local Temperature Sensor ON 1 The displayed room temperature will display the average temperature of the thermosta...

Отзывы: