Specifications

The display range of temperature ... 41˚F to 95˚F (5˚C to 35˚C)

The control range of temperature.... 44˚F to 90˚F (7˚C to 32˚C)

Load Rating............................................... 1 amp per terminal, 1.5 amp 

                                                                      maximum all terminals combined

Swing (cycle rate or differential) ...... Heating is adjustable from 0.2˚ to 2.0˚

                                                                             Cooling is adjustable from 0.2˚ to 2.0˚

Power source ...........................................18 to 30 VAC, NEC Class II, 50/60 Hz 

                                                                      for hardwire. 500 mA                                                                    

Operating ambient ............................... 32˚F to +105˚F (0˚C to +41˚C)

Operating humidity .............................. 90% non-condensing maximum

Dimensions of thermostat ................. 4.7” W x 4.3” H x 0.9” D

Frequency Range.................................... 2.4 GHz ISM radio band

WIFI.............................................................. Supporting 802.11 B/G/N Standards

45

46

Specifications 

Remote Sensor Operation

Option #1 - Indoor / Local Temperature Sensor “ON”:

1. 

The displayed room temperature will display the average

 temperature of the thermostat and all remote sensors.

2.

 By pressing the far left (Prev Step) button, the average temperature 

of just the remote sensor(s) will be displayed briefly in the clock field. 

Option #1 - Indoor / Local Temperature Sensor OFF”:

1. 

The displayed room temperature will only show the average 

temperature of the remote sensor(s).

Option #2 - Outdoor:

1. 

The outdoor temperature will alternate briefly with the clock 

display.

Option #3 (Floor)

1.

 By pressing the far left (Prev. Step) button, the temperature of the 

floor sensor will be displayed briefly in the clock field. 

Remote Sensor Operation Options

Содержание T855iSH

Страница 1: ...all 4 Wires should be pushed into the wall Installation Tips The thermostat should be installed approximately 4 to 5 feet above the floor Select an area with average temperature and good air circulati...

Страница 2: ...e the bevel on lower ridge Day of theWeek Setpoint Indicator Displays the user selectable setpoint temperature Energy Efficient Globe Indicates the setpoint temperature chosen is a efficient choice In...

Страница 3: ...gency heat relay a jumper can be installed between E and W2 to turn thermostat into a single stage control for Emergency Heat Operation 9 10 11 12 Wiring Diagrams Wiring Diagrams Typical2H 2CSystem 1T...

Страница 4: ...nd stage will turn on at 2x the swing setting The second stage will turn off when 1x the swing is reached For example if the swing setting is 5 degrees for heating and the thermostat is set at 70 F th...

Страница 5: ...pump applications OF DUAL FUEL Use the and buttons to select ON OFF SET STAGES 2H2C PROGRAM 7d 4 TIME PERIODS PRO RECOVERY This setting maximizes efficiency and equipment longevity by increasing the h...

Страница 6: ...iods is set to 2C or 4C Use the and buttons to adjust Pre Occupancy Fan Youcanselectthe pre occupancyfanfromOFF 1 2 or3hours If1 2 or3 isselected thefanwillturn onthatmanyhourspriorto thescheduledoccu...

Страница 7: ...lect OFF 10 15 20 25 30 35 40 45 50 degrees OFF BALANCE POINT OF Balance point with electric auxiliary will optimize heat pump usage When the outdoor temperature is above the AUX CUT OUT selection the...

Страница 8: ...an explanation of these options 1 1 DUM Terminal Onlyshowsif dehumidifyis setto ON DUM TERMINAL HUM Terminal DHM Terminal OPTIONS 1 2 3 4 HUM terminal energizes when the ambient humidity is Below the...

Страница 9: ...64 6 65 4 66 4 67 4 68 2 68 2 68 9 69 2 65 3 66 2 67 2 68 2 69 1 69 1 70 70 1 66 67 68 69 70 70 71 71 67 2 68 2 69 1 70 1 71 1 71 4 72 4 72 6 68 3 69 3 70 3 71 3 72 3 72 8 73 8 74 3 69 7 70 7 71 7 72...

Страница 10: ...ng 1 Select HEAT or COOL with the SYSTEM key Note You have to program heat and cool each separately 2 Press the MENU button If menu does not appear first press RUN SCHED 3 Press SET SCHED Note Monday...

Страница 11: ...F 17 C 70 F 21 C 62 F 17 C 78 F 24 C 85 F 28 C 78 F 24 C 82 F 26 C 78 F 24 C 85 F 28 C 78 F 24 C 82 F 26 C 78 F 24 C 85 F 28 C 78 F 24 C 82 F 26 C Programming Factory Default Program for 2 Time Period...

Страница 12: ...g 802 11 B G N Standards 45 46 Specifications Remote Sensor Operation Option 1 Indoor Local Temperature Sensor ON 1 The displayed room temperature will display the average temperature of the thermosta...

Отзывы: