Getting to know your thermostat

LCD

1

2

Fan Button

3

System Button

4

Menu Buttons Access Door

5

Temperature Setpoint Buttons

6

Menu Button

7

User Program Buttons

8

Displays the user 

selectable setpoint 

temperature.

Hold is displayed when

thermostat program is 

permanently overridden.

System operation 

indicators:

 The 

COOL,

HEAT

 or 

FAN

 icon will 

display when the 

COOL,

HEAT

 or 

FAN 

is on.

NOTE: The compressor 

delay feature is active if 

these icons are flashing. 

The compressor will not 

turn on until the 5 minute 

delay has elapsed.

Days of the 

week and time

Glow in the Dark Light Button

6

7

8

1

2

3

4

5

Low Battery Indicator:

Replace batteries when 

this indicator is shown.

Program Menu Options:

Shows different options

during programming.

Indicates the current

room temperature

Programmable 

Time Period Icons:

This thermostat has 

4 programmable time 

periods per day.

Important:

The low battery indicator is displayed 
when the AA battery power is low. If the 
user fails to replace the battery within 
21 days, the thermostat display will only 
show the low battery indicator as a final 
warning before the thermostat 
becomes inoperable. The batteries are 
located on the back of the thermostat.

Содержание True Comfort IIII

Страница 1: ...Installation Wiring Wiring Diagrams Technician Setup Menu Mounting and Battery Installation Programming The Thermostat Specifications Table of Contents Thermostat Applications Guide Page Battery Powe...

Страница 2: ...ld air ducts That are in direct sunlight With an outside wall behind the thermostat In areas that do not require conditioning Where there are dead spots or drafts in corners or behind doors Where ther...

Страница 3: ...until the 5 minute delay has elapsed Days of the week and time Glow in the Dark Light Button 6 7 8 1 2 3 4 5 Low Battery Indicator Replace batteries when this indicator is shown Program Menu Options...

Страница 4: ...Pro1 s products are mercury free However if the product you are replacing contains mercury dispose of it properly Your local waste management authority can give you instructions on recycling and prope...

Страница 5: ...d or non shielded 18 22 gauge thermostat wire PRO1 Tips Wiring Terminal Designations If you are replacing a thermostat make note of the terminal connections on the thermostat that is being replaced In...

Страница 6: ...C W G C L2 L1 HOT R HEAT RELAY FAN RELAY COMPRESSOR RELAY 6 2 1 FAN RELAY COMPRESSOR RELAY 6 2 HEAT RELAY FAN RELAY 6 2 Typical 1H 1C heat pump system C L2 L1 HOT R HEAT CHANGE OVER VALVE FAN RELAY CO...

Страница 7: ...es and a larger swing setting will cause fewer cycles Keypad lockout allows you to configure the thermostat so that none or some of the keys do not function The heating swing setting is adjustable fro...

Страница 8: ...he G terminal Fan Operation LCD Will Show Use the or key to select the minmum cool setpoint 44 F This feature allows you to set a minimum cool setpoint value The setpoint temperature cannot be lowerd...

Страница 9: ...ol Heat Off Cool Off Heat Off Cool Auto Allows you to put your phone number in the display You can choose ON or OFF Tech Setup Steps Continued from the previous page Contractor Call Number Beep System...

Страница 10: ...LATION Mount Thermostat Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat then push gently until the thermostat snaps in place On the back of the thermostat insert...

Страница 11: ...ng Use the or key to select the current day of the week Press NEXT STEP The current hour is flashing Use the or key to select the current hour When using 12 hour time make sure the correct a m or p m...

Страница 12: ...ime period Note If you want the fan to run continuously during this time period select ON with the FAN key Press NEXT STEP The setpoint temperature is flashing Use the or key to make your setpoint sel...

Страница 13: ...EXT STEP Repeat steps 4 thru 7 for Monday LEAVE time period for Monday RETURN time period and for Monday SLEEP time period PROGRAMMING THE THERMOSTAT 13 1 2 3 4 5 6 7 8 Repeat steps 4 thru 7 for the r...

Страница 14: ...C to 32 C 1 amp per terminal 1 5 amp maximum all terminals combined 1 F Heating is adjustable from 0 4 F to 2 0 F Cooling is adjustable from 0 4 F to 2 0 F 18 to 30 VAC NEC Class II 50 60 Hz for hard...

Отзывы: