T905

Installation Manual

Thermostat Application Guide

Description

Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Aux. or Emergency Heat)
Multi-Stage Systems
Heat Only Systems
Cool Only Systems
Millivolt

Yes
Yes
Yes

No
No

Yes
Yes
Yes

Power Type

Battery Power

Hardwire (Common Wire)

Hardwire (Common Wire) with 

Battery Backup

Table of Contents

Installation Tips

Thermostat Quick Reference

Wiring

Wiring Diagrams

Technician Setup

Programming

Page

A trained, experienced 

technician must install this 

product.

Carefully read these 

instructions.  You could damage 

this product or cause a 

hazardous condition if you fail 

to follow these instructions.

Una version en español de este 

manual se puede descargar en 

la pagina web de la compañia.

Rev. 1845

Mount Thermostat

Align the 4 tabs on the subbase with 

corresponding slots on the back of the 

thermostat, then push gently until the 

thermostat snaps in place.

Battery Installation

Battery installation is optional if thermostat is 

hardwired (R and C terminal connected to 24V 

power).

Important:

High quality alkaline batteries are recommended. 

Rechargeable batteries or low quality batteries 

do not guarantee a 1-year life span.

Insert 2 AA 

Alkaline batteries 

(included). High 

quality alkaline 

batteries are 

recommended.

Installation Tips

5

9-12

13-16

2-3 

Installation Tips

Thermostat Quick Reference

Getting to know your thermostat

Glow in the Dark Light Button
Setpoint Buttons

LCD

The low battery indicator is displayed 

when the AA battery power is low. If the 

user fails to replace the battery within 21 

days, the screen will only show the low 

battery indicator but maintain all 

functionality.  If the user fails to replace 

the batteries after an additional 21 days 

(days 22-42 since first “low battery” 

display) the setpoints will change to 55˚F 

(Heating) and 85˚F (Cooling). If the user 

adjusts the setpoint away from either of 

these, it will hold for 4 hours then return 

to either 55˚F or 85˚F.  After day 63 the 

batteries must be replaced immediately to 

avoid freezing or overheating because the 

thermostat will shut the unit off until the 

batteries are changed.

Important

Gently slide a screwdriver into the 

bottom edge of the badge. Gently turn 

the screwdriver counter clockwise.  The 

badge is held on by a magnet in the well 

of the battery door.  The badge should pry 

off easily.  

DO NOT USE FORCE.

About The Badge

All of our thermostats use the same 

universal magnetic badge.  Visit the 

company website to learn more about 

our free private label program.

Magnet in door

Use the bevel on lower ridge

Subbase Installation

The thermostat should be installed approximately 4 to 5 feet above the 

floor.  Select an area with average temperature and good air circulation.

•  Close to hot or cold air ducts

•  That are in direct sunlight

•  With an outside wall behind 

   the thermostat

•  In areas that do not require 

   conditioning

•  Where there are dead spots 

   or drafts 

   (in corners or behind doors)

•  Where there might be 

   concealed chimneys or

   pipes

Wall Locations

Vertical Mount

Horizontal Mount

For vertical mount put one screw on the top 
and one screw on the bottom.
For horizontal mount put one screw on the 
left and one screw on the right.

All of our products are mercury free. 

However, if the product you are 

replacing contains mercury, dispose of 

it properly.  Your local waste 

management authority can give you 

instructions on recycling and proper 

disposal.

Pick an installation location that is easy for 

the user to access.  The temperature of the 

location should be representative of the 

building.

Installation Tip

Mercury Notice

Do not install 

thermostat in locations:

Failure to disconnect the power before 

beginning to install this product can 

cause electrical shock or equipment 

damage.

Installation Tip: 

Electrical Hazard

      U.S. Registered Trademark. Patents pending

Copyright      2018 All Rights Reserved.

6-8

Days of the week and time

System Button
Menu Button

Fan Button

Indicates the current room 

temperature
Displays the user selectable 

setpoint temperature
Hold is displayed when thermostat 

program is permanently overridden.

System Operation Indicators:

 The 

compressor delay is active if these are 

flashing.

Programmable Time Periods: 

Residential uses 4 time periods - 

WAKE, RETURN, LEAVE

 and 

SLEEP

.

Program Menu Options:

 Shows 

different options during programming.

Low Battery Indicator:

 Replace 

batteries when this indicator is shown.

Specifications

The display range of temperature ................. 41˚F to 95˚F (5˚C to 35˚C)

The control range of temperature...................44˚F to 90˚F (7˚C to 32˚C)

Load rating..............................................................1 amp per terminal, 1.5 amp 

                                                                                   maximum all terminals combined

Swing (cycle rate or differential) .................... Heating is adjustable from 0.2˚ to 2.0˚

                                                                                        Cooling is adjustable from 0.2˚ to 2.0˚

Power source .........................................................18 to 30 VAC, NEC Class II, 50/60 Hz 

                                                                                   for hardwire - Battery power from

                                                                                   2 AA Alkaline  batteries

Operating ambient ............................................ 32˚F to +105˚F (0˚C to +41˚C)

Operating humidity .......................................... 90% non-condensing maximum

Dimensions of thermostat .............................. 4.7”W x 4.4”H x 1.1”D

9

1

7

Clean Display:

 Pressing 

CLEAN 

DISPLAY

 will allow 30 seconds to 

clean the display. The keys will be 

inoperable during this time. 

CLEAN

 

will appear if your contractor has 

programmed a filter change reminder. 

Press and hold 

CLEAN

 when filter 

has been replaced to reset the filter 

change reminder timer.

9

2

8

3

Temperature

Temperature

Pro1 Technologies

Toll Free: 888-776-1427 

Web: www.pro1iaq.com

Hours of Operation: M-F 9AM - 6PM Eastern

 

P.O. Box 3377
Springfield, MO 65808-3377