background image

 

888-545-1254 | www.PrecisionRatedOptics.com 

 

PM-501X-VFL 

Description 

The new designed optical tester which combined power meter and VFL in one tester, VFL output power 
can be adjusted. 

 

Features 

 

OPM and VFL two in one function 

 

VFL output power can be adjusted 

 

Operator easy 

 

Very useful for FTTH 

 

Specifications 

Optical Power Meter Module 
Detector Type 

InGaAs 

Measurement Range(dBm) 

-70~+6 

-50~+26 

Uncertainty  

5% 

Calibrated wavelengths(nm)   850,1300,1310,1490,1550,1625 
Resolution(dB) 

0.01 

Optical Connector 

FC/SC/2.5mm universal, for LC we provide FC-LC Hybrid adaptor   

Visual Fault Locator 
Wavelength(nm) 

650±10 

Out-put power(mW) 

Can be adjusted at 1mW, 5mW, 10mW 

 

Uncertainty 

±0.3 

General Specifications  
Power Supply 

Alkaline Battery(3 AA 1.5V batteries) 

Auto-off time  

10mins 

Operating Temperature(

-10~+60 

Storage Temperature(

-25~+70 

Dimension(mm) 

200 X90 X50 

 

Standard packages 

Power Meter +VFL, Manual, 1.5V AA Battery(3), Cotton Swabs 

 

 

Содержание PM-501X-VFL

Страница 1: ...PM 501X VFL Power Meter Visual Fault Locator Operation Guide V 12 29 17 ...

Страница 2: ...s Measurement Range dBm 70 6 50 26 Uncertainty 5 Calibrated wavelengths nm 850 1300 1310 1490 1550 1625 Resolution dB 0 01 Optical Connector FC SC 2 5mm universal for LC we provide FC LC Hybrid adaptor Visual Fault Locator Wavelength nm 650 10 Out put power mW Can be adjusted at 1mW 5mW 10mW Uncertainty 0 3 General Specifications Power Supply Alkaline Battery 3 AA 1 5V batteries Auto off time 10mi...

Страница 3: ...www PrecisionRatedOptics com 888 545 1254 3 PM 501X VFL Panel and Operation ...

Страница 4: ...rements Pressing Laser keypad to open or close 650nm VFL when VFL is activated 650nm will display on the LCD and the user that cannot perform optical power measurements Pressing Mode to adjust the output power of VFL The default output power is 10mW and can be adjusted 1mW 5mW Pressing λ to shift wavelength of optical power meter measurement Pressing UNIT to shift units between dBm and mw Pressing...

Страница 5: ...ull out connectors Remove the batteries when the battery power become weak or when the unit is not in use for extended periods This will prevent damage to the power meter from battery leakage at such times Notes Please use lens paper with cleaning liquid for sensor s surface cleaning do it in clockwise direction carefully Trouble shooting Description Probable cause Method Faint LCD display Battery...

Страница 6: ...ion Rated Optics Inc Corporate Office Billing Processing PO Box 877 Trexlertown PA 18087 Precision Rated Optics Inc Product Distribution Center Manufacturing Testing 9999 Hamilton Blvd Breinigsville PA 18031 ...

Отзывы: