CO GAS EXPOSURE VERSUS TIME  
(400 PPM EXPOSURE

 

MINUTES 

RESPONSE 

NONE 

15 

NONE 

25 

SLIGHT HEADACHE 

35 

HEADACHE 

45 

HEADACHE AND NAUSEA 

60 

DROWSY 

75 

VOMITING 

90 

COLLAPSE 

110 

COMA AND PERMANENT 
BRAIN DAMAGE 

140 

PERMANENT BRAIN 
DAMAGE – DEATH 

 
2.  SPECIFICATIONS 

 

CO ALARM RANGE 

70 PPM AND UP 

 

 

CO RESPONSE TIME 

@  70 PPM  
@150 PPM 
@ 400 PPM  

60~240 MINUTES 
10~50   MINUTES 
  4~15   MINUTES  

 

 

POWER SOURCE 

9V Battery 

 

 

OPERATING TEMPERATURE 

32

o

F (0

o

C) TO 120.2

o

F (49

o

C) 

 

 

ALARM 

85 dB AT 10 FEET 

 

 

DETECTION FREQUENCY 

SAMPLES EVERY 2 MINUTES 

 

 

1.  LCD DISPLAY (7035): 

 

1.  DIGITAL READ-OUT OF CO 

DETECTED AND PEAK LEVEL 
MEMORY 

FROM 0 PPM TO 500 PPM, WILL FLASH "500" 
IF LEVEL EXCEEDS 500 PPM. 

2.  PEAK LEVEL TIME RECORD (THE 

TOTAL TIME CO IS DETECTED 
WITHIN 10% OF THE PEAK LEVEL) 

FROM 0 TO 999 MINUTES, WILL FLASH “999” 
IF LEVEL EXCEEDS 999 MINUTES. 

3.  COHb RANGE 

(CARBOXYHEMOGLOBIN) 

FROM 0.0% TO 99.9%, WILL FLASH “99.9%” IF 
LEVEL EXCEEDS 99.9 %. 

 

 

DISPLAY TOLERANCE @ 50% RH, 
22°C±3°C IN UPRIGHT POSITION 

± 35% @ 30-500 PPM 
 

 

 

BATTERY TYPE 

ONE YEAR DURACELL MN1604 ALKALINE 
BATTERY (7030) 
OR LONG-LIFE ULTRALIFE UL9VL LITHIUM 
POWER CELL (7035) 

 

0%

5%

10%

15%

20%

25%

30%

35%

40%

45%

50%

8

15

25

35

45

60

75

90

110

140

MINUTES

COHb 100%

400 PPM EXPOSURE

Содержание 7030

Страница 1: ...OXIDE ALARM IS DESIGNED TO DETECT CARBON MONOXIDE GAS FROM ANY SOURCE OF COMBUSTION IT IS NOT DESIGNED TO DETECT SMOKE FIRE OR ANY OTHER GAS CONTENTS OF THIS MANUAL 1 INFORMATION ABOUT CARBON MONOXIDE 2 SPECIFICATIONS 3 RECOMMENDED LOCATIONS OF ALARMS 4 LOCATIONS TO AVOID 5 INSTALLATION INSTRUCTIONS 6 OPERATION AND TESTING 7 FALSE ALARMS 8 MAINTENANCE 9 LIMITATIONS OF CARBON MONOXIDE ALARMS 10 GOO...

Страница 2: ...s more tightly to the hemoglobin carboxyhemoglobin COHb than oxygen does When CO combines with hemoglobin the hemoglobin s ability to combine with oxygen is lost As the COHb concentration rises people become nauseous unconscious and ultimately die see below WHAT ARE THE SYMPTOMS OF CARBON MONOXIDE POISONING Many people often confuse carbon monoxide poisoning with the flu the initial symptoms being...

Страница 3: ...QUENCY SAMPLES EVERY 2 MINUTES 1 LCD DISPLAY 7035 1 DIGITAL READ OUT OF CO DETECTED AND PEAK LEVEL MEMORY FROM 0 PPM TO 500 PPM WILL FLASH 500 IF LEVEL EXCEEDS 500 PPM 2 PEAK LEVEL TIME RECORD THE TOTAL TIME CO IS DETECTED WITHIN 10 OF THE PEAK LEVEL FROM 0 TO 999 MINUTES WILL FLASH 999 IF LEVEL EXCEEDS 999 MINUTES 3 COHb RANGE CARBOXYHEMOGLOBIN FROM 0 0 TO 99 9 WILL FLASH 99 9 IF LEVEL EXCEEDS 99...

Страница 4: ...during this inspection have the equipment serviced immediately Note any combustion equipment not inspected by the technician and consult the manufacturer s instructions or contact the manufacturers directly for more information about CO safety and this equipment Make sure that motor vehicles are not and have not been operating in a garage or adjacent to the residence Conditions which can result in...

Страница 5: ...easily through the air similar to the scent of perfume dispersing uniformly in all directions This characteristic makes it possible for CO alarms to be mounted anywhere in the room or hallway including both wall and ceiling areas v Locate the first alarm in the immediate area of the bedrooms If more than one sleeping area exists locate additional alarms in each sleeping area v Locate an alarm in e...

Страница 6: ...r for the 7030 and 7035 CO alarms is a 9V battery BATTERY INSTALLATION AND REPLACEMENT v Open the battery door to remove the old battery for replacement and install a fresh 9 Volts battery Use Duracell MN1604 or Ultralife U9VLJ only to the battery snap v Press the battery reminder lever down place the battery on top of the lever in the battery compartment and close the battery door WARNING DO NOT ...

Страница 7: ...ODEL 7035 To retrieve from memory the CO gas detected press TEST RESET button for a minimum of five seconds The LCD will display the recorded data in the following order 1 The current CO level detected in ppm 2 The peak or highest CO level detected in ppm 3 The total length of time the alarm has detected the peak CO level in minutes and 4 The percentage of carboxyhemoglobin Each reading will appea...

Страница 8: ...f the alarm can be wiped with a damp cloth AFTER CLEANING TEST YOUR ALARM BY USING THE TEST BUTTON AND CHECK THAT THE GREEN LED IS ON 9 LIMITATIONS OF CARBON MONOXIDE ALARMS Carbon monoxide alarms are devices that can provide an early warning of the presence of CO gas at a reasonable cost However alarms have sensing limitations and may not always sound a warning in the presence of CO The alarm wil...

Страница 9: ... 2 11 SERVICE AND WARRANTY IMPORTANT SAFETY INSTRUCTIONS In the event of any trouble with the unit Do not attempt to repair the unit this product should be serviced by a qualified service technician Disconnect the battery from the unit and return the unit for servicing to the appropriate address listed on the last page of this manual Ultralife U9VL J 9 Volt 5 year Lithium Battery Returns To return...

Страница 10: ...under the terms of this limited warranty shall not in any case exceed the cost of the replacement of the CO alarm In no case shall the manufacturer or any of its parent or subsidiary corporations be liable for consequential loss or damages resulting from the failure of the CO alarm to activate or for the breach of this or any other warranty expressed or implied even if the loss or damage is caused...

Отзывы: