www.pro-team.com 866.888.2168
30
Power Nozzle
DETENT SPRING REPLACEMENT
Place vacuum on flat surface in unlocked
position exposing detent springs.
1.
Use needle nose pliers to remove detent
spring if there is adequate spring to grab.
2.
If there is not enough detent spring
to remove with pliers use a flat head
screwdriver to pry out broken spring.
3.
Place new detent spring into spring slot in
vacuum power head as shown.
4.
Push down on detent spring until fully
seated.
5.