Wire Harness
19
www.pro-team.com 866.888.2168
WIRE HARNESS REPLACEMENT
(CONTINUED FROM PAGE 18)
(Continued on page 20)
Install upper wire harness and connect the vacuum
bag full sensor.
13.
Install lower duct assembly and foam. Tighten (2)
screws. Wire harness should remain behind lower
duct assembly. Reinstall foam as shown.
12.
Connect wires as shown – Red to red. White to
white.
14.
Note: The two black wires are threaded up
through the wand guide.
Replace vacuum motor as shown.
15.
Note: motor must be properly seated. It is
properly seated when the motor can no lon-
ger rotate easily. The bulkhead will not fully
seat over the motor housing if the motor is
not properly installed.
RED
WHITE