background image

The GP477R-EG41-24VP are UL/cUL(CSA) recognized products.
(UL file No. E182139)

GP477R-EG41-24VP conforms as a component to the following standards:

• EUL508

Industrial Control Equipment

• UL1604

Electrical Equipment for Use in Class I and II Division 2 and Class III Hazardous
(Classified) Locations

• CAN/CSA-C22.2, Nos.142,and 213-M1987

Standard for Safety of Information Technology Equipment, including
Electrical Business Equipment

GP477R-EG41-24VP (UL Registration Model : 2780027-01)

• The GP should be installed in the front face of a metal panel.

• If the GP is installed so as to cool itself naturally, be sure to install it in a verti-

cal panel. Also, be sure that the GP is mounted at least 100mm away from adja-
cent structures and other equipment, otherwise, the heat generated by the GP's
internal components may become higher than that allowed by UL standard re-
quirements.

• The terminal block’s earth terminal

 is a protective earth terminal. Be sure to

connect this terminal in accordance with UL standards.

Installation and operation instructions are provided with each GP. These installation
instructions contain the following statements.

1. Power, input and output (I/O) wiring must all be in accordance with Class I, Divi-

sion 2 wiring methods, Article 501-4 (b) of the National Electrical  Code, NFPA
70, or as specified in Section 18-152 of the Canadian Electrical Code for units
installed within Canada, and in accordance with that location's authority.

2. Suitable for use in Class I, Division2, GroupsA, B, C and D hazardous location, or

nonhazardous locations only.

3. WARNING: Explosion hazard-substitution of components may impair suitability

for Class I, Division2.

4. WARNING: Explosion hazard-do not disconnect equipment unless power has been

switched off or the area is known to be nonhazardous.

5. WARNING: Explosion hazard-when in hazardous locations, turn off power before

replacing or wiring modules.

CE Marking

UL/cUL(CSA) Approval

GP477R-EG41-24VP is CE marked , EMC compliant products.These units also
conform to EN55011 class A , EN50082-2 directives.

Содержание GP477R-EG41-24VP

Страница 1: ...t or press the touch panel with too much force for it may cause irreparable damage Do not use GP in an environment where the surrounding temperature exceeds the specification range for it may damage t...

Страница 2: ...earth terminal Be sure to connect this terminal in accordance with UL standards Installation and operation instructions are provided with each GP These installation instructions contain the following...

Страница 3: ...g damaged or missing please contact your local GP distributor im mediately Package Contents Manual GP477R 577R Series User sManual Extra Cost Options Cables Adapters Screen editor software are optiona...

Страница 4: ...d terminals for AC power cable E Auxiliary Input Output AUX Operates the Touch Switch System Alarm Buzzer Run outputs and Remote Reset inputs F Serial Interface RS 232C RS 422 Serial interface Connect...

Страница 5: ...minal If necessary you may also need to connect the FG terminal to the other unit s FG terminal depending on the type of the other unit you use Pin Signal Name Condition Pin Signal Name Condition 1 FG...

Страница 6: ...PDB2 5 PDB3 6 PDB4 7 PDB5 8 PDB6 9 PDB7 10 1 INIT 11 BUSY 12 NC 13 NC 14 GND When making a cable please be aware of the following For RS 422 Connection The following pairs of pin s must be connected...

Страница 7: ...over XM2S 1511 madebyOMRONCorp JackScrew XM2Z 0071 madebyOMRONCorp Use rough metric type M2 6 x 0 45p threads used to hold the cable s set fastening screws in place 5 AUX Interface Input Output Pin Co...

Страница 8: ...screws with too much force can cause a damage Panel GPunit 1 0 1 0 Before installing the GP into a cabinet or panel check that the Installa tion gasket is securely attached to the unit Confirm the Ins...

Страница 9: ...inals with a sleeve 7 Wiring To avoid electric shock be sure the Power Cable is unplugged from the power outlet when connecting the cable to the GP unit GP477R EG41 24VP can only take DC24V input If y...

Страница 10: ...N m Please pay special attention to the following instructions when connecting the power cable to the GP unit If the supply voltage exceeds the GP unit range connect a voltage transformer For between...