Regular Service Period
1
Before
Each
Use/
Daily
First
Month
or 20
Hours
3
months
or 50
Hours
6
months
or 100
Hours
Annual
or 300
Hours
Idle Speed
Check /
Adjust
X
Valve
Clearance
Check /
Adjust
X
Combustion
Chamber
Clean
After every 500 Hours
Fuel Tank
and Filter
Clean
X
Fuel Tube
Check
Every 2 years (replace if necessary)
1
For commercial use, log hours of operation to determine proper maintenance
intervals.
2
Service more frequently when used in dusty areas.
FUEL RECOMMENDATIONS
NOTICE! Do not use unapproved gasoline, such as E85. Do
not mix oil in gasoline or modify the engine to run on
alternate fuels. This can damage the engine components. To
protect the fuel system from gum formation, mix a fuel
stabilizer into the fuel.
This engine is certified to operate on unleaded gasoline with a
minimum of 87 octane/87 AKI (91 RON). Use gasoline without ethanol
or similar alcohol based additives. Gasoline with up to 10% ethanol
(gasohol) or up to 15% MTBE (methyl tertiary butyl ether) may be used
if required.
If the engine is routinely operated at altitudes over 5,000 ft (1,524
meters), it will be necessary to have a qualified technician modify the
engine for increased performance. Fuel should be a minimum of 85
octane/85 AKI (91 RON) to prevent decreased performance.
The emissions control system for this engine is EM (Engine
Modifications).
1.
Use only an approved fuel container for refueling the engine.
2. Store fuel out of direct sunlight in a cool and dry location
3. Inspect container for fuel leaks. Replace any container that leaks.
8953176
4,5000W GASOLINE INVERTER GENERATOR
V1.0
Assistance available at www.princessauto.com or 1-800-665-8685
Page 12
Содержание 8953176
Страница 2: ...This page is intentionally left blank ...
Страница 17: ...This page is intentionally left blank ...
Страница 19: ...This page is intentionally left blank ...
Страница 41: ...Cette page a été laissée blanche intentionnellement ...
Страница 60: ...Cette page a été laissée blanche intentionnellement ...