SPECIFICATIONS 

Rated Input Flow 

6 GPM 

Maximum Pressure 

3,000 PSI 

Internal Leakage 

5 cu. in./min. @ 3,000 

PSI 

Filtration 

Requirement 

10 Micron minimum 

Temperature Range 

-30°C to 120°C  
(-22°F to 250°F) 

Power Consumption 

20W (1.7 A) 

Port Size 

8 ORB 

INTRODUCTION 

This valve is used to divert hydraulic oil flow 

entering Port 2 of the valve from one hydraulic 

circuit to a separate hydraulic circuit when 

power is applied to the coil. Oil Flows to Port 1 

when the coil is OFF. Energizing the coil 

switches the hydraulic oil flow to Port 3. 

SAFETY 

WARNING! Read and understand all 

instructions before using this device. The 

operator must follow basic precautions to 

reduce the risk of personal injury and/or 

damage to the equipment. 

Keep this manual for safety warnings, 

precautions, operating or inspection and 

maintenance instructions.  
1. 

Use the correct device for the job. This 

device was designed for a specific function. 

Do not modify or alter this device or use it 

for an unintended purpose. 

2.  Operate in a safe work environment. Keep 

your work area clean, well-lit and free of 

distractions. 

3.  Do not operate any device when tired or 

under the influence of drugs, alcohol or 

medications. 

4.  Always wear impact safety goggles that 

provide front and side protection for the eyes. 

Eye protection equipment should comply 

with CSA Z94.3-07 or ANSI Z87.1 standards 

based on the type of work performed. 

5.  Wear protective clothing designed for the 

work environment and device.  

6.  Consult the safety precautions for your 

hydraulic system when installing and 

operating this valve. 

 
 
 
 

UNPACKING 

WARNING! Do not operate the device if any 

part is missing. Replace the missing part before 

operating. Failure to do so could result in a 

malfunction and personal injury. 

Remove the parts and accessories from the 

packaging and inspect for damage. Make sure 

that all items in the parts list are included. 
Contents:

  

• 

Solenoid Valve 

ASSEMBLY  

WIRING 

1. 

Connect positive wire (+) 

to terminal 1. 

2.  Connect negative wire (-) 

to terminal 2. 

 

OPERATION 

Hydraulic oil flows from 

Port 2 to Port 1 when the 

coil is not energized.  

Applying power to the 

coil activates the valve 

and the hydraulic oil 

from Port 2 is diverted 

to Port 3. 

12V DC 3-WAY, 2-POSITION DIRECTIONAL CONTROL VALVE 