19
going to be used for an extended period of time, the seacock valve should be in the closed
position. To activate the pump, depress the switch to the up or forward position. To turn the
pump off after the baitwell tub is full, depress switch to the down or aft position.
11
12
Port & Starboard Fishbox Pump Outs- These 2 switches operate the fishbox macerator pumps
that allow you to drain the water and debris from the fishboxes. The macerator pumps, which are
mounted on the outside of the port and starboard aft stringers, allow you to pump all the water,
ice and scales out of the boxes by grinding up the debris and discharging it overboard.
To activate either one of the pumps, depress the applicable switch to the up or forward position.
This action will drain the applicable fishbox of water and/or debris, grind up any debris and then
discharge the water and/or debris overboard. When not in use, the switches should be left in the
off or down position.
13 Bilge Lights – Two bilge lights are mounted on the port and starboard stringers to illuminate the
bilge area when you are working on your boat in low visibility conditions. To activate the lights,
depress the switch to the up or forward position. Make sure to leave switch in the off or down
position when the bilge lights are not in use.
14
15
16
Bilge Pumps (Bilge 1, Bilge 2, Fwd) - Your boat is equipped with 3 automatic bilge pumps.
Bilge 1 – This 1100 gph pump is located in the aft bilge. If your vessel is equipped
with a generator, the pump is located just forward of the generator. The
automatic float switch is mounted next to the pump.
Bilge 2 - This 1500 gph pump is the high water bilge pump and it is located in the
aft bilge, in close proximity to bilge pump 1. The automatic float switch for this
high water pump is mounted further aft in the bilge, on the port side.
Fwd Bilge - This 1100 gph pump is located and is accessible via the panel under
the mattress in the mid berth.
All bilge pumps are wired automatic to the battery and have a manual override located at the
switch panel on the console. The automatic float switches are wired directly to the
Starboard
battery terminals through breakers or inline fuses. Circuit breakers for the main and forward
pumps are located at the helm next to the manual switches.
Depressing the applicable bilge pump switch (Bilge 1, Bilge 2 or Fwd) to the up or forward position
activates the corresponding bilge pump. When not in use, the switches should be left in the off
or down position.
Circuit Breakers
Circuit breakers and/or fuses protect the wiring. In the event a device stops working, check to see if the
circuit breaker is tripped or if the fuse is blown. Breakers are installed in the following locations:
The main breaker is located above the dual battery switches and is accessible via the
battery switch hatch located below the transom sink.
Additional breakers and/or fuses for the bilge pumps, trim tabs, and stereo memory are
located next to the main breaker.
Additional breaker switches are also located on the switch panel above the individual
switches.
A tripped breaker will protrude or move from its set position indicating that the circuit has been overloaded.
Turn off the device(s) on the circuit, then reset the breaker by pushing in once or by returning a breaker
switch to the on position. If the breaker does not reset or if it resets and then trips again after the device is
turned back on, then a short circuit exists or your device may be damaged, overloaded, or faulty. Correct
the problem and then reset the breaker.