background image

© Audio Trade GmbH · Pro-Ject 1 

X

pression III Comfort / Ortofon 2M Red · Revision 1.6.08/1.7.08

 

5

Adjusting the azimuth 

** The cartridge needle must be vertical in the record groove in order to trace 
the groove wall modulations correctly. 
A small screw at the bearing end of the arm allows incorrect azimuth to be 
corrected if your needle is not mounted exactly perpendicular to the cartridge 
body (which is often the case). 
Slacken off the screw just enough to be able to revolve the arm tube without 
applying force. Note! Do not remove the screw completely!

 

Screw

 

With the aid of a good magnifying glass adjust the needle until it is vertical in the groove (i.e. perpendicular 
to the record's surface). Ideally this should correspond to the top surface of the cartridge body being parallel 
to the record surface. When you are satisfied that the needle is vertical retighten the screw carefully.

 

 

Under no circumstances should the arm tube be adjusted with the needle still in the record groove! 

Irreparable damage may be caused to the cantilever suspension! The arm must be lifted to make 
each adjustment and lowered afterwards to check it. 

Anti-skating force adjustment

 

The anti-skating force must be adjusted according to the mass of the cartridge 
as follows: 
Downforce 

 

Groove in the stub (15) 

10 - 14mN 

 

1

st

  from bearing rings 

15 - 19mN 

 

2

nd

    "         "         " 

20mN and bigger

 

3

rd

     "         "         "

 

 

Slip the loop of the anti-skating weight's thread over the third groove of the stub to set the correct anti-skating 
force for the factory-fitted cartridge. Feed the thread through the loop of the wire support (17).

 

Connection to the amplifier 

The record player has gold plated female RCA phono sockets (14) so you can substitute the interconnect 
cables supplied with those of your choice for connection to the amplifier if you wish. Your dealer can advise 
you on alternative cables. Use the Phono input (sometimes labelled gram, disc or RIAA) on your amplifier. Make 
sure that the phono input offers correct matching and amplification for the type of cartridge used. Line inputs 
(such as CD, Tuner, Tape or Video) are not suitable. 
Take care to connect the left and right channels correctly. The right channel is usually marked red, the left 

channel black or white. Check the manual supplied with your amplifier for relevant information. The earthing 
wire of the tonearm lead should be connected to the earth terminal on your amplifier (if provided). 
If your amplifier does not have an input suitable for phono cartridges you will require a separate phono 
amplifier stage for MM or MC cartridges such as the PRO-JECT PHONO BOX or the PRO-JECT TUBE BOX 
which is then connected between the record player and a free line level input of the amplifier. 
For detailed product information please refer to the Pro-Ject web site 

www.project-audio.com

 

The recommended load resistance for the factory fitted cartridge is: 

47kohms

/

MM-input

 

Fitting the lid 

Fit the lid (dust cover 10) carefully over the hinge prongs and adjust the screws (12) until the lid stays open 
where you want it to without being too stiff to open or close. 

Using the automatic start & stop facility 

Before starting record replay, lower the tonearm lift lever until it is about horizontal. By switching the power 
on/off switch (20) record replay can be started and stopped at any position across the record. The tonearm 
lift is raised or lowered accordingly when the power is turned on or off. 

 

The tonearm cannot be lowered manually whilst the turntable is turned off, as it is held in position by 

an electromagnetic switch. 
The manual lift function is only available when the turntable is turned on and the platter is revolving.

 

Содержание Pro-Ject 1 Xpression III Comfort

Страница 1: ...INSTRUCTIONS FOR USE Pro Ject 1 Xpression III Comfort...

Страница 2: ...Audio Trade GmbH Pro Ject 1 Xpression III Comfort Ortofon 2M Red Revision 1 6 08 1 7 08 2 1 1...

Страница 3: ...h anti scratch cups 24 Speed change Connection cable not shown Power supply not shown Single adapter not shown Dear music lover thank you for purchasing a PRO JECT AUDIO record player In order to achi...

Страница 4: ...oved up or down This adjustment must be done carefully Do not forget to remove the cartridge protection cap if fitted Once the arm is correctly balanced return it to the rest Hold the counterweight 6...

Страница 5: ...th those of your choice for connection to the amplifier if you wish Your dealer can advise you on alternative cables Use the Phono input sometimes labelled gram disc or RIAA on your amplifier Make sur...

Страница 6: ...ance surface such as wood or multiple layer ply board to avoid structural vibrations disturbing replay Fitting and connecting the cartridge All cartridges with half inch mounting holes can be fitted L...

Страница 7: ...er bearing without oil dirty or damaged Service Should you encounter a problem which you are not able to alleviate or identify despite the above information please contact your dealer for further advi...

Страница 8: ...io Trade GmbH Pro Ject 1 Xpression III Comfort Ortofon 2M Red Revision 1 6 08 1 7 08 8 Tomearm transport look 2 motor transport screws marked red Lid Platter Accessories Tonearm counterweight Power su...

Отзывы: