8
• Press “
START/STOP
” button to clean the result when finished
• If an error occurs during counting, see Table 8
• Repeat operations up to Table 6.4., when necessary
7
Function settings
ATTENTION! Follow these guidelines carefully to avoid errors during operation.
7.1. Adjustment of the slot size
Remember! Adjusting the feeder slot size is possible by using the paper thickness adjustment
screw (Fig. 1-5) on the rear panel. Turn the screw counterclockwise to decrease the feeder
slot size and clockwise to increase the size. The feeder slot should be larger for excessively
worn banknotes, dirty banknotes and USD. The feeder slot should be smaller for “new” ban-
knotes. Adjust turning should be done smoothly, with a pitch of 5 degrees or less. Counter
speed should be 1200 banknotes per minute.
If adjusting the feeder slot size results in the sensor responding slowly, slow separation of
joined banknotes, irregular stacking of banknotes, and/or error “HAF” occurs, then the slot
size should be smoothly increased without exceeding a rotation of more than 5 degrees.
If adjusting the feeder slot size results in “dbL”, “dd”, or “CHn” error codes occuring frequent-
ly, then the slot size should be smoothly decreased without exceeding a rotation of more than
5 degrees.
7.2. Change settings
To enter the mode for changing the device’s settings, press the digit button “5” three times on
the control panel.
7.2.1. Changing the sensitivity level for UV detection
Press “
SET
” button until the “CF-1” sign shows on the display. Enter a number from 0 to 3,
which corresponds a sensitivity level from low to high. “0” corresponds to UV detection being
turned OFF.
Press “
START/STOP
”. Recommended level: CF-1=2.
7.2.2. Changing the acceptable width range for banknotes
Press “
SET
” button until “dd” sign shows on the display. Enter a number from 3 to 7, which
corresponds to a width sensitivity level from 3 to 7mm. “0” corresponds to size detection being
turned OFF. Press “
START/STOP
” button. Recommended level: dd=4
7.2.3. Change the sensitivity of optical density
Press “
SET
” button until “dBL” sign appears. Enter the level of optical density (0-7). Larger
values correspond to more dense notes. Smaller values correspond to less dense or older /
worn notes. Press “
START/STOP
” button. Recommended level: dBL=4
Attention! New settings are stored for future use.
Remember! Wrong settings can cause failures and frequent error messages. Error
messages listed in Table 8.
Содержание PRO 95
Страница 1: ...PRO 95 SERIES PRO 95 PRO 95U www pro intell com User manual Currency counters English...
Страница 3: ...3 2 Appearance Figure 1...
Страница 5: ...5 Figure 2...
Страница 12: ...PRO INTELLECT TECHNOLOGY www pro intell com...