9
System errors. Service.
In order to provide the best functioning of the device, it is necessary to comply with the
following simple requirements:
Switch off the device, when not in use
Use protective cover, when not in use
Clean the hopper and stacker with a clean dry cloth. Sensors can cause errors when
dirty.
It is recommended to carry out preventive measures, including partial disassembling of
the counter each 30 days by an engineer in the service center.
Code
Reason
Solution
E-1
Left sensor is either blocked or failed.
Switch off and then switch on the power, clean
the sensor or contact the service center
E-2
Right sensor is either blocked or
failed.
Switch off and then switch on the power, clean
the sensor or contact the service center
E-3
Tachometer sensor is either dirty or
failed.
Contact service centre.
E-4
UV sensor is either blocked or failed.
Switch off and then switch on the power, clean
the sensor or contact the service center
E-5
Sensor in the hopper is blocked by
the banknotes or is dirty.
Remove banknotes from the hopper, clean or
replace the sensor.
E-6
Sensor in the stacker is blocked by
the banknotes or is dirty.
Remove banknotes from the stacker, clean or
replace the sensor.