background image

E-17

„

„

„

„

„

USB Cable Holder Installation

This holder prevents the USB cable from becoming disconnected due to vibration,
etc.

  

Place the PS-A unit face-down on a flat surface as shown below. Your PS-A

unit has two USB connectors.

• When using both USB connectors, be sure to first connect one USB cable to

the lower USB connector, then connect the second USB cable to the upper
USB connector.

• When using only one of the USB ports, be sure to use the lower USB connec-

tor. This allows you to securely clamp the USB cable in the cable clamp.

Upper USB Interface
Lower USB Interface

USB Cable

Clamp

Band

Bridge

Cable Collars

Clip

Clamp

[Attachment]

As shown below, insert the USB Cable Clamp’s band through the Bridge.  Pass the
USB cables through the Cable Clamp’s band and securely tighten the clamp band
around the cables.

• Be sure the clamp is securely holding the USB cable’s plug and collar.

• Be sure the clamp is positioned as shown below, with the clamp pointing

upwards – not to the side. This is to keep the clamp from interfering with
nearby connectors and their cables.

[Removal]

To remove the clamp from the USB cables, push down on the clamp strap’s clip to
release it while pulling up on the clamp.

Содержание PS-3701A

Страница 1: ...e related or important disaster prevention situations For safety related switches such as an emergency switch be sure to use a separate mechanical switch The PS A is not appropriate for use with aircr...

Страница 2: ...according to the manufacturer s instructions Be sure the unit the PS A unit is built into uses a UL508 compatible structure UL CSA Application Notes CE Marking Notes The PS3701A T41 DU E66 unit is CE...

Страница 3: ...nal item s Installation Guide Please use that guide to check the contents of each optional item s package Package Contents PS A Unit 1 PS3701A T41 DU E66 Installation Guide 1 This Guide Installation F...

Страница 4: ...e form of a self extracting file is located in this CD ROM in the folder titled reader Use the Explorer software to find the file Reader Eng ar505enu exe and double click on the file icon to begin the...

Страница 5: ...RS 232C RS 422 RS 485 Changeover RI 5V Changeover 15 Serial Interface COM1 RS 232C RI 5V Changeover 16 Speaker Output Interface SPEAKER 17 Printer Interface LPT1 18 CF Card Interface Cover 19 Power P...

Страница 6: ...shows the PS A unit with installation fasteners Unit mm in Front Top 60 2 36 282 11 10 Side 5 0 20 395 15 55 294 11 57 383 15 08 394 8 15 54 160 6 30 160 6 30 165 6 50 160 6 30 404 8 15 94 303 8 11 9...

Страница 7: ...ust Pollution Degree Pollution Degree 2 Corrosive Gases Free of corrosive gases Vibration Resistance 19 6m s2 at 10Hzto 25Hz without HDD 4 9m s2 at 10Hzto 25Hz with HDD Noise Immunity via noise simula...

Страница 8: ...e original protection level Schneider Electric recommends that you replace the instal lation gasket regularly Structural Grounding 100 or less or your country s applicable standard Ratings 1 Equivalen...

Страница 9: ...F OFF ON OFF ON 5 Switches the TX termination resistance ON OFF Inserts termination resistance of 220 between TXAand TXB No termination OFF OFF ON ON OFF 1 6 Switches the RX termination resistance ON...

Страница 10: ...place COM2 COM2 can be changed to either RS 232C RS 422 or RS 485 The default setting is RS 232C To change this setting to RS 422 or RS 485 open the PS A unit s rear cover and set dip switch DIPSW2 t...

Страница 11: ...me Ground Be sure to connect pin number 5 SG of COM1 to the host unit s Signal Ground terminal Be sure to confirm what settings will be used by the other device and set the dip switches accordingly Fa...

Страница 12: ...DATA5 DATA5 In Output O D 8 DATA6 DATA6 In Output O D 9 DATA7 DATA7 In Output O D 10 ACKNLG ACKNLG Input TTL 11 BUSY WAIT Input TTL 12 PE PE Input TTL 13 SLCT SLCT Input TTL 14 AUTOFD DSTRB In Output...

Страница 13: ...with the display panel facing downward Check that the PS A s installation gasket is seated securely into the gasket s groove which runs around the perimeter of the panel s frame Before installing the...

Страница 14: ...hook section into the slot and tighten the fastener with a screwdriver as shown Insertion Slots Top Bottom Left side Right side Installation Fastener Panel PS A Unit mm in Create a Panel Cut Insert t...

Страница 15: ...er model CA3 ATFALL 01 Attach the PS A unit to an Arm To attach the PS A unit to an Arm or to the wall insert the attachment screws for a commercial type arm or wall mount adaptor into the holes in th...

Страница 16: ...e PS A s maintainability operability and ventilation allow at least 100 mm clearance between the PS A and other objects The clearance must be large enough to allow you to install or uninstall option u...

Страница 17: ...the USB cable in the cable clamp Upper USB Interface Lower USB Interface USB Cable Clamp Band Bridge Cable Collars Clip Clamp Attachment As shown below insert the USB Cable Clamp s band through the B...

Страница 18: ...use power other than DC24V you can damage both the power supply and the PS A unit Since the PS A unit has no power ON OFF switch be sure to attach a breaker type switch to its power cord WARNINGS 1 Po...

Страница 19: ...nal lines must be separated from the power control cables for operational circuits To increase noise resistance be sure to twist the ends of the power cord wires before connecting them to the PS A uni...

Страница 20: ...lectronics Corporation 11 Replacing the Backlight Using any backlight other than the model written above may cause an accident or PS A unit malfunction The PS A unit s backlight is user replacable For...

Отзывы: