WARNING

WARNINGS

• When inserting the PS-3701A(Eden

 ESP6000 - 667MHz Model) (hereafter referred to as the

"PS-A")'s power cord into the PS-A's Power Plug, check first that the PS-A's power supply is

completely turned OFF, via a breaker, or similar unit.

• Before either plugging in or unplugging interface connector, be sure to turn the PS-A’s power

OFF.

• Whenever changing the Backlight, to prevent electric shocks and burns, be sure to turn OFF the

PS-A's power and wear protective gloves.

• After the PS-A’s backlight burns out, unlike the PS-A’s “Standby Mode”, the touch panel is still

active. If the operator fails to notice that the backlight is burned out and touches the panel, a

potentially dangerous machine operation error can occur.

If your PS-A's backlight suddenly turns OFF, use the following steps to determine if the
backlight is actually burned out.

1)

If your PS-A is not set to "Standby Mode" and the screen has gone blank, your backlight is

burned out.

2)

Or, if your PS-A is set to Standby Mode, but touching the screen does not cause the
display to reappear, your backlight is burned out.

• Do not open or remodel the PS-A unit, since it may lead to a fire or electric shock.
• Do not use power beyond the PS-A unit's specified voltage range.  Doing so may cause a fire or

electric shock.

• Do not use the PS-A unit in an environment where flammable gases are present, since operat-

ing the PS-A unit may cause an explosion.

• The PS-A uses a lithium battery for backing up its internal clock data.  If the battery is incorrectly

replaced (i.e. its + and - sides are reversed), the battery may explode. When changing the

battery, please contact your local PS-A distributor.

• Do not use the PS-A unit as a warning device for critical alarms that can cause serious operator

injury, machine damage or production stoppage. Critical alarm indicators and their control/acti-

vator units must be designed using stand-alone hardware and/or mechanical interlocks.

• To prevent operator injury or machine damage, be sure to design your machine operation sys-

tem so that the machine will not malfunction due to a communication fault between the PS-A

and its host controller.

• Do not use PS-A touch panel switches in life-related or important disaster prevention situations.  For

safety related switches, such as an emergency switch, be sure to use a separate mechanical switch.

• The PS-A is not appropriate for use with aircraft control devices, aerospace equipment, central

trunk data transmission (communication) devices, nuclear power control devices, or medical life

support equipment, due to these devices inherent requirements of extremely high levels of

safety and reliability.

• When using the PS-A with transportation vehicles (trains, cars and ships), disaster and crime

prevention devices, various types of safety equipment, non-life support related medical devices,

etc. redundant and/or failsafe system designs should be used to ensure the proper degree of

reliability and safety.

To prevent this unit from malfunctioning :

• In order to extend the lifetime of the hard disk, Pro-face recommends you set the Windows [Con-

trol panel]-[Power Management option]-[Turn off hard disks] selection to turn the hard disk off

when the unit is not being operated.  A setting of 5 minutes is recommended.

• Do not strike the PS-A's touch panel with a hard or heavy object, or press on the touch panel with

excessive force, since it may damage the display.

• Do not install the PS-A where the temperature will exceed its specified range.
• Be sure that water, liquids or metal particles do not enter the PS-A, since  it may cause a malfunc-

tion or a short circuit.

• Avoid installing the PS-A where sudden, large changes in temperature may occur. These changes

may cause condensation to form inside the unit, possibly causing a malfunction.

• To prevent excessive heat from building up inside the PS-A, do not install it where its ventilation

holes may be blocked. Also, do not install or store the PS-A near high temperature equipment.

• Do not install or store the PS-A in direct sunlight or where high levels of dust exist.
• Since the PS-A is a precision instrument, do not install or store it where either strong shocks or

excessive vibration may occur.

• Do not install or store the PS-A in an area containing chemicals or chemical fumes.
• Do not use paint thinner or organic solvents to clean the PS-A's case or screen.
• Due to the danger of unforeseeable accidents, back up all PS-A data regularly.
• After turning this unit OFF, be sure to wait a few seconds before turning it ON again. If the unit is

started too soon, it may not start up correctly.

Содержание PS-3701A

Страница 1: ...e related or important disaster prevention situations For safety related switches such as an emergency switch be sure to use a separate mechanical switch The PS A is not appropriate for use with aircr...

Страница 2: ...according to the manufacturer s instructions Be sure the unit the PS A unit is built into uses a UL508 compatible structure UL CSA Application Notes CE Marking Notes The PS3701A T41 DU E66 unit is CE...

Страница 3: ...nal item s Installation Guide Please use that guide to check the contents of each optional item s package Package Contents PS A Unit 1 PS3701A T41 DU E66 Installation Guide 1 This Guide Installation F...

Страница 4: ...e form of a self extracting file is located in this CD ROM in the folder titled reader Use the Explorer software to find the file Reader Eng ar505enu exe and double click on the file icon to begin the...

Страница 5: ...RS 232C RS 422 RS 485 Changeover RI 5V Changeover 15 Serial Interface COM1 RS 232C RI 5V Changeover 16 Speaker Output Interface SPEAKER 17 Printer Interface LPT1 18 CF Card Interface Cover 19 Power P...

Страница 6: ...shows the PS A unit with installation fasteners Unit mm in Front Top 60 2 36 282 11 10 Side 5 0 20 395 15 55 294 11 57 383 15 08 394 8 15 54 160 6 30 160 6 30 165 6 50 160 6 30 404 8 15 94 303 8 11 9...

Страница 7: ...ust Pollution Degree Pollution Degree 2 Corrosive Gases Free of corrosive gases Vibration Resistance 19 6m s2 at 10Hzto 25Hz without HDD 4 9m s2 at 10Hzto 25Hz with HDD Noise Immunity via noise simula...

Страница 8: ...e original protection level Schneider Electric recommends that you replace the instal lation gasket regularly Structural Grounding 100 or less or your country s applicable standard Ratings 1 Equivalen...

Страница 9: ...F OFF ON OFF ON 5 Switches the TX termination resistance ON OFF Inserts termination resistance of 220 between TXAand TXB No termination OFF OFF ON ON OFF 1 6 Switches the RX termination resistance ON...

Страница 10: ...place COM2 COM2 can be changed to either RS 232C RS 422 or RS 485 The default setting is RS 232C To change this setting to RS 422 or RS 485 open the PS A unit s rear cover and set dip switch DIPSW2 t...

Страница 11: ...me Ground Be sure to connect pin number 5 SG of COM1 to the host unit s Signal Ground terminal Be sure to confirm what settings will be used by the other device and set the dip switches accordingly Fa...

Страница 12: ...DATA5 DATA5 In Output O D 8 DATA6 DATA6 In Output O D 9 DATA7 DATA7 In Output O D 10 ACKNLG ACKNLG Input TTL 11 BUSY WAIT Input TTL 12 PE PE Input TTL 13 SLCT SLCT Input TTL 14 AUTOFD DSTRB In Output...

Страница 13: ...with the display panel facing downward Check that the PS A s installation gasket is seated securely into the gasket s groove which runs around the perimeter of the panel s frame Before installing the...

Страница 14: ...hook section into the slot and tighten the fastener with a screwdriver as shown Insertion Slots Top Bottom Left side Right side Installation Fastener Panel PS A Unit mm in Create a Panel Cut Insert t...

Страница 15: ...er model CA3 ATFALL 01 Attach the PS A unit to an Arm To attach the PS A unit to an Arm or to the wall insert the attachment screws for a commercial type arm or wall mount adaptor into the holes in th...

Страница 16: ...e PS A s maintainability operability and ventilation allow at least 100 mm clearance between the PS A and other objects The clearance must be large enough to allow you to install or uninstall option u...

Страница 17: ...the USB cable in the cable clamp Upper USB Interface Lower USB Interface USB Cable Clamp Band Bridge Cable Collars Clip Clamp Attachment As shown below insert the USB Cable Clamp s band through the B...

Страница 18: ...use power other than DC24V you can damage both the power supply and the PS A unit Since the PS A unit has no power ON OFF switch be sure to attach a breaker type switch to its power cord WARNINGS 1 Po...

Страница 19: ...nal lines must be separated from the power control cables for operational circuits To increase noise resistance be sure to twist the ends of the power cord wires before connecting them to the PS A uni...

Страница 20: ...lectronics Corporation 11 Replacing the Backlight Using any backlight other than the model written above may cause an accident or PS A unit malfunction The PS A unit s backlight is user replacable For...