Touch Panel Commands
4-2
FP-790T User Manual
Calibration mode ON 73h
Starts touch panel calibration mode. (Same function as when SW1-5 is
ON.)
Calibration mode OFF 74h
Ends touch panel calibration mode. (Same function as when SW1-5 is
OFF.)
Touch data ON
75h
Enables touch panel data output.
Touch data OFF
76h
Disables touch panel data output.
Buzzer
Click
Status
ON
ON
Buzzer ON
ON
OFF
Buzzer ON
OFF
ON
Click sound ON
OFF
OFF
Buzzer and click sound OFF
Priority is given to buzzer output over the click sound. Thus, when
both the buzzer output and click sound are set to ON, the buzzer
output is activated.
Backlight ON (High brightness) 65h
Turns on the backlight at high brightness.
Backlight OFF (Automatic reset)
67h
Turns off the backlight. When either SIO communication or touch
operation is performed, the backlight is turned on.
Backlight OFF (Command reset)
68h
Turns off the backlight. After a different serial command (e.g. 65h, 66h) is
received, the backlight is turned on.
Click sound ON
69h
Every time you touch the display panel a click will sound.
Click sound OFF
6Ah
Turns off the click sound.
Buzzer ON
71h
Turns on the buzzer output
Buzzer OFF
72h
Turns off the buzzer output.