-16-
LCD Display and Menu Screen (DR
*
-B
*****
)
The PRO-iO2 LCD display shows the following RUN/STOP status and time
information. Pressing the Menu/Ok button displays the Menu Screen.
The following settings can be entered using this screen.
(Pressing the Z1 key returns to the previous display screen.)
7
PROGRAMMING
: Logic program monitoring can be performed in RUN
mode. Logic program creation/update can be performed in
STOP mode.
In RUN mode, “MONITORING” is displayed.
PARAMETER
: Timer and Counter parameters can be changed even in
RUN mode.
RUN/STOP
: Select whether to run or stop the PRO-iO2 module.
CONFIGURATION
: Designates the following settings (This function is
disabled in RUN mode.):
PASSWORD
: Designates the password needed to access the logic
program. Press the Menu/Ok button to enable the
setting, select a password using the Z1 to Z4 keys,
and press the Menu/Ok button again to confirm the
password. To cancel the setting, hold down the Shift
button and then press the Menu/Ok button. Deleting
the password will require the same password to be
entered again. A valid password can be any four
digit number (0000 to 9999).
FILT
: Designates the input filter time. The module is
designed only for a DC input filter. Select either
SLOW (3ms to 5ms), or FAST (0.3ms to 0.5ms).
Z1 key
Shift button
Menu/Ok button
PRO-iO2 RUN/STOP Status
Programming language: LD
(Ladder Diagram)
Z2 key
Z3 key Z4 key
Day of week/date/month/
time
Output Terminal Indicator
(When a terminal turns ON, that
terminal’s number turns grey)
Input Terminal Indicator
(When a terminal turns ON, that terminal’s number turns grey)